Solar Pump error codes by brand

Pick your brand to see the solar pump codes we cover, what each one means, and what you can safely check yourself. Each code links back to the brand's own manual or support page.

अपना ब्रांड चुनें और डिस्प्ले पर दिख रहे कोड का मतलब और हल देखें।

Pick your brand ब्रांड चुनें

INVT 41 codes listed · 7 full guides A-LL · A-LS · OC1 · OL1 · PVLV · PVOV · SPO Shakti 29 codes listed · 1 full guide 05

INVT solar pump codes at a glance

All INVT Goodrive100-PV solar pump inverter fault and alarm codes from INVT's own manual: PVLV, PVOV, PINV, A-LS weak light, A-LL no water, OC, OV, UV, SPO and more, with causes.

INVT GD100-PV सोलर पंप इन्वर्टर के फ़ॉल्ट कोड INVT के मैनुअल से। A- से शुरू होने वाले कोड (A-LS कम धूप, A-LL पानी नहीं, A-tF टंकी भरी, A-tL पानी खाली) अलार्म हैं: धूप या पानी आने पर पंप खुद चल जाता है। PVLV मतलब पैनल का वोल्टेज कम, PVOV मतलब ज़्यादा, PINV मतलब पैनल की तार उल्टी लगी।

CodeModel typeMeaning
OUt1GD100-PVInverter unit U-phase protection
OUt2GD100-PVInverter unit V-phase protection
OUt3GD100-PVInverter unit W-phase protection
OV1GD100-PVOvervoltage during acceleration
OV2GD100-PVOvervoltage during deceleration
OV3GD100-PVOvervoltage during constant speed running
OC1GD100-PVOvercurrent during acceleration
OC2GD100-PVOvercurrent during deceleration
OC3GD100-PVOvercurrent during constant speed running
UVGD100-PVBus undervoltage
OL1GD100-PVMotor overload
OL2GD100-PVInverter overload
SPIGD100-PVPhase loss on the input side
SPOGD100-PVPhase loss on the output side
OH1GD100-PVRectifier module overheating (P07 list: boost module overheat)
OH2GD100-PVInverter module overheat
EFGD100-PVExternal fault
CEGD100-PVRS485 communication fault
ItEGD100-PVCurrent detection fault
tEGD100-PVMotor autotuning fault

All 41 INVT codes with what to do for each

Shakti solar pump codes at a glance

What Shakti solar pump drive and controller fault codes mean, from Shakti's own installation manuals: 01 Low Power, 02 DC Bus Under Voltage, 05 Dry Run, 06 Over Temp, 08 Short Circuit, 11 PMSM Start Fail and the Kalpavriksha USPC codes, with what to check.

Shakti सोलर पंप ड्राइव की LCD पर नंबर और संदेश आता है, जैसे 05 DRY RUN DETECTED। Nandi, Lotus और Simha Plus में 01 से 12 तक एक ही टेबल है; Kalpavriksha USPC के नंबर अलग हैं। 01 LOW POWER खराबी नहीं, चेतावनी है: पैनल से बिजली कम आ रही है (अक्सर धूप कम होने से)।

CodeModel typeMeaning
01Nandi, Lotus, Simha Plus solar drivesLow power: input power is low because of weak sunlight or shadow on the panels, panels not in healthy condition, or solar power below the minimum PV power setting. Lotus and Simha Plus mark this as a warning, not a fault.
02Nandi, Lotus, Simha Plus solar drivesDC bus under voltage: low input power (weak sunlight or shadow on panels), panels not in healthy condition, or a sudden high power draw by the motor because the pump or motor is jammed
03Nandi, Lotus, Simha Plus solar drivesDC bus over voltage: the DC bus voltage in the drive is more than the set voltage
04Nandi, Lotus, Simha Plus solar drivesOutput over voltage: the output side voltage is high when the drive is off
05Nandi, Lotus, Simha Plus solar drivesDry run: no water on the suction / inlet side of the pump
06Nandi, Lotus, Simha Plus solar drivesOver temperature: the drive is heating more than expected, or ventilation is poor
07Nandi, Lotus, Simha Plus solar drivesOver current at output: the output current (RMS) is more than the value set in the drive's factory setup. Causes: wrong rated current set, or the connected load does not match the selected parameters.
08Nandi, Lotus, Simha Plus solar drivesShort circuit trip: an internal or output connection is shorted, the voltage is too low, or there was a sudden load
09Nandi, Lotus, Simha Plus solar drivesHigh inrush current: sudden increase in load, wrong motor selected, or a cable joint not done properly
10Nandi, Lotus, Simha Plus solar drivesOutput open circuit: one of the outputs opened while running
11Nandi, Lotus, Simha Plus solar drivesPMSM start fail: starting torque not enough, or the pump or motor is mechanically jammed
12Nandi, Lotus, Simha Plus solar drivesUnbalance fault: one of the three phases is missing
01Kalpavriksha USPC, 2022 manualLow power: input power is less than the set minimum power (weak sunlight or shadow on panels, panels not healthy, or solar power below the minimum PV power setting)
02Kalpavriksha USPC, 2022 manualDC bus over voltage: the DC bus voltage is more than the set voltage
05Kalpavriksha USPC, 2022 manualDry run: no water on the suction / inlet side of the pump
06Kalpavriksha USPC, 2022 manualWrong motor: the wrong type of motor is connected, for example an induction motor instead of PMSM, or the other way round
08Kalpavriksha USPC, 2022 manualHigh inrush current: sudden increase in load, wrong motor selected, or a cable joint not done properly
09Kalpavriksha USPC, 2022 manualOutput open circuit: one of the outputs opened while running
18Kalpavriksha USPC, 2022 manualPV over voltage: the average panel (PV) voltage is above 765 V
19Kalpavriksha USPC, 2022 manualPV under voltage: the average panel (PV) voltage is below 150 V

All 29 Shakti codes with what to do for each