INVT Solar Pump Inverter Fault Codes (GD100-PV): PVLV, A-LS, A-LL, OC, OV and More

By FaultDecode · Checked against INVT's official documents · Updated · How we check

41 INVT codes on this page.

INVT's Goodrive100-PV (GD100-PV) is a solar pump inverter: it runs a water pump straight from solar panels, with grid power as an option. This list comes from Chapter 7 of INVT's GD100-PV operation manual (V1.7). Codes starting with A- are alarms, not faults: the pump stops or sleeps and starts again on its own when sunlight or water comes back. Other codes are faults: the TRIP light is on and the code blinks on the keypad.

Safety: INVT's manual says only qualified electricians may work on the inverter. Before any wiring or inspection, disconnect every supply (the solar panel DC input and any grid AC input) and wait at least the time marked on the inverter (5 minutes for most models, 15 minutes for 3PH 380V 132–200 kW) or until the DC bus voltage is below 36 V. High voltage is present inside while it runs, so do nothing except keypad settings. Do not touch it with wet hands.

How to see the code

  1. Read the code that blinks on the keypad. The TRIP light is on during a fault.
  2. Codes starting with A- (A-LS, A-LL, A-tF, A-tL) are alarms. The pump sleeps and restarts by itself when the condition clears.
  3. Past faults are stored in parameters P07.27 (current fault) and P07.28 onward (previous faults), shown as numbers. The number is in brackets next to each code below.
  4. After the cause is fixed, reset with the STOP/RST key, a control terminal, or a communication command. If the fault is still there, the code stays on the display.

How to check the error code on other solar pump brands

INVT solar pump error code list

Applies to: GD100-PV

CodeMeaningWhat to do
OUt1 (fault type 1) Inverter unit U-phase protection Acceleration too fast, IGBT module damaged, interference, poor drive wire connection, or a short to ground. INVT: increase ACC time, check drive wires and interference; replace the power unit if damaged.
OUt2 (fault type 2) Inverter unit V-phase protection Same causes and fixes as OUt1.
OUt3 (fault type 3) Inverter unit W-phase protection Same causes and fixes as OUt1.
OV1 (fault type 7) Overvoltage during acceleration Input voltage abnormal, large energy feedback, no braking components, or dynamic brake disabled (INVT gives the same causes for OV1, OV2 and OV3). INVT: check the input power, check whether the DEC time is too short or the inverter starts while the motor is turning, install braking components, check related settings.
OV2 (fault type 8) Overvoltage during deceleration Same causes and fixes as OV1.
OV3 (fault type 9) Overvoltage during constant speed running Same causes and fixes as OV1.
OC1 (fault type 4) Overcurrent during acceleration · full fix Acceleration or deceleration too fast, low grid voltage, inverter power too low, abnormal load, short to ground or output phase loss, strong interference, or overvoltage stall protection disabled.
OC2 (fault type 5) Overcurrent during deceleration Same causes as OC1.
OC3 (fault type 6) Overcurrent during constant speed running Same causes as OC1.
UV (fault type 10) Bus undervoltage Grid voltage too low or overvoltage stall protection disabled. INVT: check the grid input power and related settings.
OL1 (fault type 11) Motor overload · full fix Grid voltage too low, motor rated current set wrong, or motor stall or sudden load change. INVT: check the grid voltage, reset the motor rated current, check the load and adjust torque boost.
OL2 (fault type 12) Inverter overload Acceleration too fast, a rotating motor was reset, grid voltage too low, load too heavy, or motor power too small. INVT: increase ACC time, avoid restarting right after a stop, check the grid voltage, select a larger inverter or a proper motor.
SPI (fault type 13) Phase loss on the input side Phase loss or violent fluctuation on input R, S, T. INVT: check input power and installation wiring.
SPO (fault type 14) Phase loss on the output side · full fix Phase loss on U, V, W, or the three load phases are seriously unequal. INVT: check output wiring, motor and cable.
OH1 (fault type 15) Rectifier module overheating (P07 list: boost module overheat) Air duct blocked or fan damaged, ambient temperature too high, or overload for too long.
OH2 (fault type 16) Inverter module overheat Same causes as OH1. INVT: clear the vent duct or replace the fan, lower the ambient temperature.
EF (fault type 17) External fault An external fault input terminal (SI) acted. INVT: check the external device input.
CE (fault type 18) RS485 communication fault Wrong baud rate or address, wiring fault, or strong interference.
ItE (fault type 19) Current detection fault Control board connector loose, Hall device damaged, or amplifier circuit fault.
tE (fault type 20) Motor autotuning fault Motor capacity does not match, motor parameters set wrong, autotuned values far from standard, or autotuning timed out.
EEP (fault type 21) EEPROM operation fault Error reading or writing control parameters, or EEPROM damaged. INVT: press STOP/RST; change the main control board if it stays.
PIDE (fault type 22) PID feedback disconnection PID feedback signal wire disconnected or the feedback source is gone.
bCE (fault type 23) Braking unit fault Listed in the fault record (P07.27) only; no cause given in the fault table.
END (fault type 24) Running time reached The inverter has run longer than its internal set running time. INVT: ask the supplier to adjust the preset running time.
OL3 (fault type 25) Electronic overload Overload pre-alarm reached the set threshold. INVT: check the load and the overload pre-alarm threshold.
ETH1 (fault type 32) To-ground short-circuit fault 1 Inverter output is shorted to ground. INVT: check the motor wiring.
ETH2 (fault type 33) To-ground short-circuit fault 2 Fault in the current detection circuit. INVT: replace the Hall device or change the main control board.
dEu (fault type 34) Speed deviation fault Load too heavy or stalled.
STo (fault type 35) Mal-adjustment fault SM control parameters wrong, autotuned parameters not accurate, or the inverter is not connected to the motor.
LL (fault type 36) Electronic underload Underload pre-alarm reached the set threshold. INVT: check the load and the underload pre-alarm threshold.
tSF (fault type 37) Hydraulic probe damage The hydraulic (water level) probe is damaged. INVT: replace the probe.
PINV (fault type 38) PV reverse connection fault Solar panel (PV) wiring is reversed. INVT: swap the positive and negative wiring and wire it again.
PVOC (fault type 39) PV overcurrent ACC or DEC too fast, inverter power too low, abnormal load, or short to ground.
PVOV (fault type 40) PV overvoltage · full fix Solar panel input voltage too high, or model -4 set as another model.
PVLV (fault type 41) PV undervoltage · full fix Too little panel power in series, cloudy or rainy weather, or motor starting current too high.
E-422 (fault type 42) Fault on 422 communication with the boost module The four 422 communication cables are in poor contact.
OV (fault type 43 (boost side)) Bus overvoltage detected on the boost side Sunlight changes sharply. INVT: adjust the boost PI parameters and increase P19.07 and P19.08.
A-LS (alarm) Weak-light pre-alarm (not a fault) · full fix Sunlight is weak or the panel setup is too small. The pump sleeps and restarts by itself when light is enough.
A-LL (alarm) Underload pre-alarm (not a fault) · full fix The pumping pool (well or tank) has no water. INVT: check the pumping pool.
A-tF (alarm) Full-water pre-alarm (not a fault) The pool or tank is full. With the full-water function set up, the pump stops after a delay; otherwise check the level terminal wiring.
A-tL (alarm) Empty-water pre-alarm (not a fault) The pool has no water. With the empty-water function set up, the pump stops after a delay; otherwise check the level terminal wiring.

Good to know

हिंदी में

INVT GD100-PV सोलर पंप इन्वर्टर के फ़ॉल्ट कोड INVT के मैनुअल से। A- से शुरू होने वाले कोड (A-LS कम धूप, A-LL पानी नहीं, A-tF टंकी भरी, A-tL पानी खाली) अलार्म हैं: धूप या पानी आने पर पंप खुद चल जाता है। PVLV मतलब पैनल का वोल्टेज कम, PVOV मतलब ज़्यादा, PINV मतलब पैनल की तार उल्टी लगी।

  1. कीपैड पर झपकता कोड पढ़ें। फ़ॉल्ट में TRIP बत्ती जलती है।
  2. A- वाले कोड में धूप या पानी आने तक रुकें।
  3. बाकी फ़ॉल्ट में वायरिंग का काम सिर्फ़ इलेक्ट्रीशियन करे। पैनल और ग्रिड दोनों की सप्लाई काटें और इन्वर्टर पर लिखा समय (ज़्यादातर मॉडल में 5 मिनट) रुकें।
  4. कारण ठीक होने पर STOP/RST दबाकर रीसेट करें।

Questions people ask

What does A-LS mean on a solar pump?

On the INVT GD100-PV, A-LS is the weak-light pre-alarm: sunlight is too weak or the panel setup is too small. It is not a fault. The pump sleeps and runs again by itself when light is enough (by default after a 300 s wake-up delay).

What does PVLV mean?

PV undervoltage: the solar panel input voltage is too low. INVT lists too few panels in series, cloudy or rainy weather, or a motor with too high starting current.

Is A-LL a fault?

No. A-LL is the underload pre-alarm. INVT's table gives the cause as the pumping pool having no water, so check the well or tank.

Which code is the dry run error on an INVT solar pump?

INVT does not use the words "dry run". The nearest codes are alarms, not faults: A-LL (underload pre-alarm), which INVT says means the pumping pool (well or tank) has no water, and A-tL (empty-water pre-alarm). Check the water level in the well or tank. The fault LL (electronic underload) means the underload pre-alarm reached its set threshold.

My INVT solar pump is not working. What should I check first?

Read the code on the drive's display. A-LS means the sunlight is too weak or the panel setup too small: the pump sleeps and restarts by itself when the light improves. PVLV means the panel voltage is too low (cloudy weather, too few panels in series, or a high motor starting current). A-LL or A-tL means no water in the well or tank. A-tF means the tank is full. If a fault code (no A- in front) stays, call the installer or INVT service.

Sources