INVT Solar Pump OC1, OC2, OC3 Fault: Overcurrent

Quick answer

OC1, OC2 and OC3 on an INVT Goodrive100-PV solar pump inverter are overcurrent faults: OC1 during acceleration, OC2 during deceleration and OC3 at constant speed. INVT lists the same causes for all three: acceleration or deceleration too fast, grid voltage too low, inverter power too low for the pump, an abnormal or changing load, a short to ground or output phase loss, strong interference, or overvoltage stall protection disabled.

OC1, OC2 and OC3: when the current went too high

The number tells you when it happened: OC1 during acceleration, OC2 during deceleration, OC3 at constant speed. In the fault record they are numbers 4, 5 and 6 (P07.27 onward).

Who fixes it

This is installer and electrician work. An electrician should check the output wiring for a short circuit and check the pump turns smoothly. The installer can increase the ACC time and check the input power and settings, as INVT advises. If the pump is too big for the inverter, INVT says to select an inverter with larger power.

Safety: Only a qualified electrician should open the inverter or touch the panel, pump or motor wiring. INVT's manual says to disconnect every supply (solar panel DC input and any grid AC input) and wait at least the time marked on the inverter (5 minutes for most models) or until the DC bus voltage is below 36 V before any wiring or inspection. High voltage is present inside while it runs.

Common causes

  • Acceleration or deceleration too fast
  • Grid voltage too low
  • Inverter power too low for the pump
  • Load changing suddenly or abnormal (pump jammed or not turning smoothly)
  • Short circuit to ground or between wires, or output phase loss
  • Strong external interference
  • Overvoltage stall protection disabled

Fix it step by step

  1. Switch off all supplies and wait the time marked on the inverter before anyone touches wiring.
  2. Have an electrician check the output wiring and look for a short circuit (to ground or between wires) in the load, and check the pump turns smoothly.
  3. Ask the installer to increase the ACC time, check the input power and check related settings, as INVT advises.
  4. If the pump is too big for the inverter, INVT says to select an inverter with larger power.

Still showing OC1?

  • PVOC is a separate PV-side overcurrent code with similar causes.