INVT Solar Pump A-LL: Underload Alarm (No Water in Well or Tank)

Quick answer

A-LL on an INVT Goodrive100-PV solar pump inverter is the underload pre-alarm. INVT's fault table gives one cause: the pumping pool has no water, and the fix is to check the pumping pool. The inverter sees the pump running with too little current for a set time, which is what a pump with no water to lift looks like. By default it reports A-LL after 60 seconds of underload running (P15.19). The reset delay (P15.21, default 120 s) is counted from the same start, so the alarm resets about 60 seconds after it appears.

What A-LL means

It is a pre-alarm, separate from the LL code.

What to check

Check the well, borewell or tank the pump draws from, as INVT says to check the pumping pool, and let the water level recover.

If there is water and A-LL keeps coming, call the installer: the underload detection settings (P15.19, P15.20) or the pump and pipe need checking.

A-LL, A-tL and LL

A-LL is detected from the pump's low current. A-tL is the empty-water pre-alarm from a water level signal, used only if a level switch or sensor is set up. LL (without A-) is electronic underload, when the underload pre-alarm reaches its threshold.

Common causes

  • No water in the well, borewell or tank the pump draws from
  • Pump running with too little load for the underload time (default 60 s)

Fix it step by step

  1. Check the water source. INVT says to check the pumping pool.
  2. Let the water level recover. By default the alarm resets about 60 seconds after it appears (reset delay P15.21 of 120 s minus the 60 s underload run time P15.19).
  3. If there is water and A-LL keeps coming, call the installer: the underload detection settings (P15.19, P15.20) or the pump and pipe need checking.

Still showing A-LL?

  • LL (without A-) is a separate code: electronic underload, when the underload pre-alarm reaches its threshold. Check the load and threshold.

हिंदी में

INVT सोलर पंप में A-LL का मतलब है पंप पर लोड कम है, यानी कुएं, बोरवेल या टंकी में पानी नहीं है और पंप सूखा चल रहा है।

  1. पानी का स्रोत (कुआं, बोरवेल, टंकी) देखें।
  2. पानी आने दें। अलार्म डिफ़ॉल्ट सेटिंग में लगभग 1 मिनट बाद अपने आप रीसेट होता है।
  3. पानी होते हुए भी बार-बार आए तो इंस्टॉलर को बुलाएं।