Water Purifier error codes by brand
Pick your brand to see the water purifier codes we cover, what each one means, and what you can safely check yourself. Each code links back to the brand's own manual or support page.
अपना ब्रांड चुनें और डिस्प्ले पर दिख रहे कोड का मतलब और हल देखें।
- A code is showingPick your brand below, then find your code.डिस्प्ले पर कोड दिख रहा है
- Only a light is blinkingHow to read the code on each brand.सिर्फ लाइट ब्लिंक हो रही है
Pick your brand ब्रांड चुनें
Aquaguard water purifier codes at a glance
What Aquaguard (Eureka Forbes) RO purifier lights mean, from Eureka Forbes' own user manuals: red service light (UV lamp, solenoid valve or pump error), blue power light blinking (no input water), LED ring faults on Crest, and filter life warnings.
Aquaguard प्यूरीफ़ायर में नंबर वाले कोड नहीं आते, लाइट से खराबी पता चलती है। Delight NXT में लाल Service लाइट जले = UV लैंप खराब, लाल झपके = वाल्व या पंप खराब, नीली Power लाइट तेज़ झपके = पानी नहीं आ रहा। Crest में LED का गोला अलग-अलग तरह से झपकता है।
| Code | Model type | Meaning |
|---|---|---|
| UV lamp error | Delight NXT RO+UV+UF+TA | UV lamp error |
| SV / pump error | Delight NXT RO+UV+UF+TA | Solenoid valve (SV) or pump error |
| LPS error | Delight NXT RO+UV+UF+TA | No input water (LPS error) |
| Temperature sensor fault | Crest UV Hot | Temperature sensor fault |
| UV / LDR fault | Crest UV Hot | UV lamp or LDR fault |
| SV fault | Crest UV Hot | Solenoid valve (SV) fault |
| EA fault | Crest UV Hot | EA fault: both EA chips not connected, or the main board to junction board harness not connected |
| EA fault: combination cartridge | Crest UV Hot | EA fault on the combination cartridge (blue) |
| EA fault: active copper cartridge | Crest UV Hot | EA fault on the active copper cartridge with zinc booster (beige) |
| UV / LDR fault | Zest RO+UV+MTDS+Hot / Crest UV | UV lamp or LDR fault |
| SV / pump fault | Zest RO+UV+MTDS+Hot / Crest UV | Solenoid valve (SV) or pump fault |
| Filter first warning | Zest RO+UV+MTDS+Hot / Crest UV | Filter end of life is nearing (first warning). LED 5 = combination cartridge, LED 1 = active copper with zinc booster. |
| Filter second warning | Zest RO+UV+MTDS+Hot / Crest UV | Filter second warning (end of life is near) |
| Filter end of life | Zest RO+UV+MTDS+Hot / Crest UV | Filter has reached end of life. Eureka Forbes says the unit is seized (stops) at end of life. |
KENT water purifier codes at a glance
What KENT RO water purifier warnings and alarms mean, from KENT's own user manuals: Perk Star error codes E02 to E35, Star-B and IoT screen warnings (UV fail, change filter, change membrane, no water input, mineral content), and the beep alarms on non-digital models.
ज़्यादातर KENT RO में नंबर वाले कोड नहीं आते। डिजिटल मॉडल (Star-B, IoT) में स्क्रीन पर चेतावनी आती है, जैसे UV फ़ेल, फ़िल्टर बदलें, मेम्ब्रेन बदलें, पानी नहीं आ रहा। बिना स्क्रीन वाले मॉडल बीप से बताते हैं, जैसे हर दो सेकंड में 4 छोटी बीप = फ़िल्टर बदलने का समय। E02 से E35 कोड सिर्फ़ Perk Star डिस्पेंसर में आते हैं।
| Code | Model type | Meaning |
|---|---|---|
| E02 | Perk Star hot & cold dispenser with RO | Abnormal working: the system kept producing water for 16 hours without stopping. It stops producing water and sterilizing. |
| E05 | Perk Star hot & cold dispenser with RO | Abnormal heating: it heated for 1 hour but the temperature did not go above 50 °C. Heating stops. |
| E07 | Perk Star hot & cold dispenser with RO | Water leakage: the leakage sensor detected water for 15 seconds. The system shuts down. |
| E09 | Perk Star hot & cold dispenser with RO | Hot water temperature sensor (NTC) malfunction: its reading was outside the limit for 15 seconds. Heating stops. |
| E18 | Perk Star hot & cold dispenser with RO | Cold water temperature sensor (NTC) malfunction: its reading was outside the limit for 15 seconds (KENT's table says heating stops). |
| E22 | Perk Star hot & cold dispenser with RO | Abnormal liquid level switch position. The system shuts down. |
| E35 | Perk Star hot & cold dispenser with RO | Abnormal communication between the display board and the system. The system shuts down. |
| UV fail | Ace / Grand / Supreme Star-B | UV lamp or UV LED failure. With a lamp failure the purifier stops purifying water until the UV lamp is replaced. |
| Tank UV fail | Ace / Supreme / Sterling IoT | Tank UV LED failure |
| Inline UV fail | Ace / Supreme / Sterling IoT | Inline UV failure. The purifier stops purifying water until the inline UV is replaced. |
| Replace filter | Star-B and IoT models | Filter life is used up. The purifier stops purifying water until the filters are replaced. |
| Change membrane | Ace / Supreme / Sterling IoT | RO membrane life is used up. The purifier stops purifying water until it is replaced. |
| Low RO flow | Star-B and IoT models | The RO membrane's capacity has dropped. The purifier keeps working until the membrane fails. |
| No water input | Star-B and IoT models | No water is coming in. The purifier switches off and stays off until the water supply is restored. |
| Mineral content low | Star-B and IoT models | The TDS (mineral content) of the purified water is below the permissible range. |
| Mineral content high | Star-B and IoT models | The TDS (mineral content) of the purified water is above the permissible range. |
| 4 short beeps | Supreme-B, Excell+, Grand Plus, Maxx; non-digital | Filter change alarm: filters are due for a change (Supreme-B, Excell+, Grand Plus: after 700 hours of use since the last filter change or installation). |
| Continuous beep | Supreme-B, Excell+, Grand Plus, Maxx; non-digital | Filters not changed within 60 hours of the filter change alarm. The purifier has stopped and will not work until the filters are changed. |
| 1 short beep every 2 seconds | Grand Plus, Excell+, Maxx, Elixir-1 | UV lamp failure. On Grand Plus and Maxx the purification process stops. |
| 2 beeps | Grand Plus | UV LED failure |