हिंदी

KENT RO Error Codes, Warnings and Beeps: Perk Star E02 to E35, Change Filter, UV Fail, No Water Input

By FaultDecode · Checked against KENT's official documents · Updated · How we check

21 KENT codes on this page.

Most KENT RO purifiers do not show number codes. KENT's manuals describe three kinds of signal: screen warnings on digital models (Star-B and IoT, for example UV fail, change filter, no water input), beep alarms on models without a screen (for example 4 short beeps for a filter change), and real error codes (E02 to E35) only on the Perk Star hot and cold water dispenser with built-in RO. Every row here is from KENT's own user manuals on kent.co.in. Find your model name on the purifier's front or its label, then match what you see or hear.

Safety: A purifier that has stopped because of a UV failure or used-up filters will not give safe water until it is serviced: KENT says the purifier stops purifying in these cases. Switch it off and call a KENT service technician. On the Perk Star, a water leakage code (E07) shuts the system down: unplug it and call service. Do not open the purifier yourself.

How to see the code

  1. Digital models (Star-B, IoT): look at the warning signs on the screen, such as UV fail, change filter, change membrane or no water input, and the mineral content bar (green, yellow or orange, red).
  2. Models without a screen: listen to the beep pattern, for example 4 short beeps every two seconds, one short beep every two seconds, or a beep that does not stop.
  3. Perk Star dispenser: read the code on the display, for example E07.
  4. Match what you see or hear and your model in the table below.

How to check the error code on other water purifier brands

KENT water purifier error code list

CodeModel typeMeaningWhat to do
E02 Perk Star hot & cold dispenser with RO Abnormal working: the system kept producing water for 16 hours without stopping. It stops producing water and sterilizing. KENT's table says: power on again after troubleshooting. If E02 comes back, call KENT service.
E05 Perk Star hot & cold dispenser with RO Abnormal heating: it heated for 1 hour but the temperature did not go above 50 °C. Heating stops. KENT's table says: power on again after troubleshooting. If E05 comes back, call KENT service (the troubleshooting table, under 'water does not come out hot', lists a damaged heating element or hot tank thermostat).
E07 Perk Star hot & cold dispenser with RO Water leakage: the leakage sensor detected water for 15 seconds. The system shuts down. Unplug the dispenser and call KENT service. KENT's table says to replug only after troubleshooting (the leak is found and fixed). Do not open the unit.
E09 Perk Star hot & cold dispenser with RO Hot water temperature sensor (NTC) malfunction: its reading was outside the limit for 15 seconds. Heating stops. Switch off the purifier and call a KENT service technician. Do not open the purifier.
E18 Perk Star hot & cold dispenser with RO Cold water temperature sensor (NTC) malfunction: its reading was outside the limit for 15 seconds (KENT's table says heating stops). Switch off the purifier and call a KENT service technician. Do not open the purifier.
E22 Perk Star hot & cold dispenser with RO Abnormal liquid level switch position. The system shuts down. Unplug and plug in again. If E22 comes back, call KENT service (the troubleshooting table, under 'tank does not fill', lists a damaged level switch or electronic board).
E35 Perk Star hot & cold dispenser with RO Abnormal communication between the display board and the system. The system shuts down. Unplug, plug in again and wait for communication. If E35 stays, call KENT service.
UV fail (screen warning; one beep for UV lamp, blinking sign with two beeps for UV LED) Ace / Grand / Supreme Star-B UV lamp or UV LED failure. With a lamp failure the purifier stops purifying water until the UV lamp is replaced. Switch off the purifier and call a KENT service technician. Do not open the purifier.
Tank UV fail (blinking screen warning with a long beep) Ace / Supreme / Sterling IoT Tank UV LED failure Switch off the purifier and call a KENT service technician. Do not open the purifier.
Inline UV fail (screen warning with a continuous beep) Ace / Supreme / Sterling IoT Inline UV failure. The purifier stops purifying water until the inline UV is replaced. Switch off the purifier and call a KENT service technician. Do not open the purifier.
Replace filter (screen message with a continuous buzzer; IoT: Change Filters) Star-B and IoT models Filter life is used up. The purifier stops purifying water until the filters are replaced. Switch off the purifier and call a KENT service technician. Do not open the purifier.
Change membrane (screen message with a continuous buzzer) Ace / Supreme / Sterling IoT RO membrane life is used up. The purifier stops purifying water until it is replaced. Switch off the purifier and call a KENT service technician. Do not open the purifier.
Low RO flow (warning sign; IoT: Change Membrane and LPH sign) Star-B and IoT models The RO membrane's capacity has dropped. The purifier keeps working until the membrane fails. Call KENT customer care and ask for a membrane replacement.
No water input (screen warning) Star-B and IoT models No water is coming in. The purifier switches off and stays off until the water supply is restored. Check that the water supply to the purifier is on. On Star-B models the purifier does not start if inlet pressure is below 0.3 kg/cm². If water is coming and the warning stays, call KENT service.
Mineral content low (bar in yellow (Star-B) or orange (IoT) zone, with a warning sign) Star-B and IoT models The TDS (mineral content) of the purified water is below the permissible range. KENT's Star-B manual says: call customer care or log in to the app.
Mineral content high (bar in red zone, with a warning sign) Star-B and IoT models The TDS (mineral content) of the purified water is above the permissible range. KENT's Star-B manual says: call customer care or log in to the app.
4 short beeps (every two seconds, for 30 seconds, repeats every 2 hours of use) Supreme-B, Excell+, Grand Plus, Maxx; non-digital Filter change alarm: filters are due for a change (Supreme-B, Excell+, Grand Plus: after 700 hours of use since the last filter change or installation). Call a KENT service technician to change the filters. If they are not changed within the next 60 hours of use, the purifier stops working.
Continuous beep (does not stop) Supreme-B, Excell+, Grand Plus, Maxx; non-digital Filters not changed within 60 hours of the filter change alarm. The purifier has stopped and will not work until the filters are changed. Switch off the purifier and call a KENT service technician. Do not open the purifier.
1 short beep every 2 seconds (UV fail alarm) Grand Plus, Excell+, Maxx, Elixir-1 UV lamp failure. On Grand Plus and Maxx the purification process stops. Switch off the purifier and call a KENT service technician. Do not open the purifier.
2 beeps (UV LED fail alarm) Grand Plus UV LED failure Switch off the purifier and call a KENT service technician. Do not open the purifier.
UV alarm (alarm sound) Smart Plus, Ultra Storage with Active Copper; UV only The UV lamp is not drawing enough current from the power source. Switch off the purifier and call a KENT service technician. Do not open the purifier.

Good to know

हिंदी में

ज़्यादातर KENT RO में नंबर वाले कोड नहीं आते। डिजिटल मॉडल (Star-B, IoT) में स्क्रीन पर चेतावनी आती है, जैसे UV फ़ेल, फ़िल्टर बदलें, मेम्ब्रेन बदलें, पानी नहीं आ रहा। बिना स्क्रीन वाले मॉडल बीप से बताते हैं, जैसे हर दो सेकंड में 4 छोटी बीप = फ़िल्टर बदलने का समय। E02 से E35 कोड सिर्फ़ Perk Star डिस्पेंसर में आते हैं।

  1. स्क्रीन पर चेतावनी पढ़ें, या बीप ध्यान से सुनें: कितनी बीप, कितनी देर में।
  2. No Water Input आए तो देखें कि प्यूरीफ़ायर तक पानी आ रहा है। पानी आने पर प्यूरीफ़ायर फिर चलेगा।
  3. UV फ़ेल, फ़िल्टर बदलें या मेम्ब्रेन बदलें आए, या बीप लगातार बजे, तो प्यूरीफ़ायर बंद करें और KENT टेक्नीशियन बुलाएं। तब तक यह पानी साफ़ नहीं करता।
  4. Perk Star में E07 (पानी लीक) आए तो प्लग निकालें और KENT सर्विस बुलाएं।
  5. प्यूरीफ़ायर खुद न खोलें।

Questions people ask

What are the error codes on a KENT RO?

Most KENT RO purifiers have no number codes. Digital models (Star-B, IoT) show warning signs on the screen, such as UV fail, change filter, change membrane and no water input. Models without a screen use beeps. Of the KENT manuals we checked, only the Perk Star hot and cold dispenser with built-in RO shows codes, E02 to E35.

Why is my KENT RO beeping 4 times?

On Supreme-B, Excell+, Grand Plus and Maxx, 4 short beeps every two seconds for 30 seconds is the filter change alarm (Supreme-B, Excell+ and Grand Plus: after 700 hours of use since the last filter change). Call a KENT service technician to change the filters. If they are not changed within the next 60 hours of use, the purifier stops and beeps continuously.

Why is my KENT RO beeping continuously?

On Supreme-B, Excell+, Grand Plus and Maxx, a continuous beep means the filters were not changed within 60 hours after the filter change alarm, so the purifier has stopped. On Star-B and IoT models, a continuous buzzer comes with the Replace Filter (IoT: Change Filters) message, and on IoT models also with Change Membrane. On IoT models, a continuous beep with the Inline UV fail warning means the inline UV has failed and the purifier has stopped purifying. Switch off the purifier and call a KENT service technician.

What does UV fail mean on a KENT purifier?

The UV lamp or UV LED has failed. With a UV lamp failure, KENT says the purifier stops purifying water until the lamp is replaced. On non-digital models you hear one short beep every two seconds (on Grand Plus, two beeps for a UV LED failure). Switch off and call a KENT service technician.

My KENT RO shows No Water Input. What should I do?

The purifier is getting no water and has switched itself off. KENT says it stays off until the water supply is restored. Check that the tap supply is on. On Star-B models it also does not start if the inlet pressure is below 0.3 kg/cm².

Sources

Last checked:

↑