हिंदी

Inverter / UPS error codes by brand

Pick your brand to see the inverter / UPS codes we cover, what each one means, and what you can safely check yourself. Each code links back to the brand's own manual or support page.

अपना ब्रांड चुनें और डिस्प्ले पर दिख रहे कोड का मतलब और हल देखें।

Pick your brand ब्रांड चुनें

Luminous 8 codes listed Microtek 27 codes listed

Luminous inverter / UPS codes at a glance

What Luminous inverter / UPS display codes and indicator lights mean (Zelio+ Lbt and oLd, Eco Volt Neo overload and low battery), from Luminous's own user manuals.

Luminous इन्वर्टर दो तरह से खराबी बताते हैं: Zelio+ जैसे मॉडल स्क्रीन पर Lbt या oLd लिखते हैं, Eco Volt Neo जैसे मॉडल लाइट से बताते हैं।

CodeModel typeMeaning
LbtZelio+ (1100, 1700)Battery low; the battery may be discharged
oLdZelio+ (1100, 1700)UPS tripped because the load is too high
Mains indicator offZelio+ (1100, 1700)Mains is normal but the UPS is not taking it: loose plug, dead socket, MCB trip, or mains too low or high
Mains ON but no outputZelio+ (1100, 1700)Mains indicator glows but there is no output; the output plug may be loose
ON MAINS offEco Volt Neo (750–1650)Mains is normal but the unit is on battery: loose plug, dead socket, mains too low or high, or a blown fuse / tripped MCB
LOW BATT. glowingEco Volt Neo (750–1650)In battery mode, the battery has been discharged by recent use
UPS OVERLOAD steadyEco Volt Neo (750–1650)The unit tripped on overload
OVERLOAD blinkingEco Volt Neo (750–1650)The unit tripped because of a short circuit in UPS mode

Luminous codes with what to do for each

Microtek inverter / UPS codes at a glance

What Microtek inverter / UPS display codes, lights and beeps mean, from Microtek's own user manuals: LCD codes oLd, bLo, bHI, SHt Ct, otP and Cbt, the Heavy Duty LED and beep table, and what to do.

Microtek LCD इन्वर्टर में कोड दिखता है: oLd (ओवरलोड), bLo (बैटरी कम), SHt Ct (शॉर्ट सर्किट), otP (ज़्यादा गर्म), Cbt (MCB गिरा)। Heavy Duty मॉडल में कोड नहीं आता, खराबी LED और बीप से पता चलती है।

CodeModel typeMeaning
oLdElite 1500 LCD, JM SW 2500+ (LCD models)Overload warning: the load is too high
oLdElite 1500 LCD, JM SW 2500+ (LCD models)Overload shutdown: the UPS has switched off its output
bLoElite 1500 LCD, JM SW 2500+ (LCD models)Battery low warning
bLoElite 1500 LCD, JM SW 2500+ (LCD models)Battery low shutdown: the battery is discharged
bHIElite 1500 LCD, JM SW 2500+ (LCD models)Battery high shutdown: battery voltage too high
SHt CtElite 1500 LCD, JM SW 2500+ (LCD models)Output short circuit (the UPS shuts its output)
otPElite 1500 LCD, JM SW 2500+ (LCD models)Over temperature protection
CbtElite 1500 LCD, JM SW 2500+ (LCD models)Input circuit breaker trip
LoElite 1500 LCD, JM SW 2500+ (LCD models)Mains is on but its voltage or frequency is too low (out of the normal range). In backup mode the UPS runs on battery; in mains mode with the power switch off, the output shows oFF
HIElite 1500 LCD, JM SW 2500+ (LCD models)Mains is on but its voltage or frequency is too high (out of the normal range). In backup mode the UPS runs on battery; in mains mode with the power switch off, the output shows oFF
CHrElite 1500 LCDCharger status, shown in mains mode after the input voltage and frequency: CHr on, or CHr on / FUL (the manual says the 0.1 icon means the display shows CHr Ful). A clock icon shows the remaining charging time
oFFElite 1500 LCDOutput is off: standby (only the battery connected, ON/OFF switch off), or mains mode with the power switch off
Mains LED flashingHeavy Duty VTurbo NEW (SW and DG)The MCB (circuit breaker) at the back has tripped
Inverter or UPS LED glowingHeavy Duty VTurbo NEW (SW and DG)The UPS is running on battery even though mains power is there: dead wall socket, or loose or wrong mains input connection
Overload LED glowing (red)Heavy Duty VTurbo NEW (SW and DG)Overload: too much load on the UPS
Overload LED glowing (red)Heavy Duty VTurbo NEW (SW and DG)Short circuit in the output
Battery Low and Overload LEDs glowingHeavy Duty VTurbo NEW (SW and DG)Over-temperature protection
Overload LED glowing (red)Heavy Duty VTurbo NEW (SW and DG)Another fault (the Overload LED also flashes or glows for over charging and DC high)
Battery Low LED glowing (red)Heavy Duty VTurbo NEW (SW and DG)Battery has discharged
Charging LED flashingHeavy Duty VTurbo NEW (SW and DG)Battery is charging (normal)

All 27 Microtek codes with what to do for each