Microtek Inverter Error Codes, Beeps and LEDs: oLd, bLo, SHt Ct, otP, Cbt
Microtek home UPS models show faults in two ways. LCD models such as Elite 1500 LCD and Jumbo JM SW 2500+ show short codes like oLd (overload) or bLo (battery low). Heavy Duty VTurbo NEW models (1400, 1550 and 1750 on 12 V; 2000 and 2350 on 24 V, SW and DG versions) show no codes: they use six front LEDs (Mains, Inverter, UPS, Charging, Batt Low, Overload), a buzzer and an "SW LED" that the manual's buzzer table lists as on or off (the manual does not say which light this is). Every row here is from Microtek's own user manuals for these models. Other Microtek models may behave differently.
Safety: Microtek's manual says: do not open the UPS, there are dangerous high voltages inside even when the power is off. Installation should be done by a knowledgeable person, and battery polarity must be checked before connecting: a wrong polarity connection blows the reverse protection fuse and may cause a fire. Always switch off the UPS and disconnect mains before disconnecting the battery. For a short circuit that stays, a backfeed fault, an MCB that trips again or an alarm that keeps buzzing after a reset, switch the UPS off and call Microtek authorised service.
How to see the code
- LCD models (Elite LCD, JM): read the code on the display, for example 000 oLd. On the Elite LCD, also note whether the warning icon blinks (warning) or glows steady (shutdown).
- Look at the six LEDs on the front: Mains, Inverter, UPS, Charging, Batt Low and Overload. Note which ones glow steady and which flash.
- Listen to the buzzer: one beep, one 0.5 second beep, a continuous alarm or no alarm.
- Note whether the SW LED is on or off. Microtek's buzzer table pairs each buzzer pattern with this LED's state, but the manual does not say which light it is.
- Match what you see and hear in the table below.
Microtek inverter / UPS error code list
| Code | Model type | Meaning | What to do |
|---|---|---|---|
| oLd (shown as 000 oLd; icon blinking, Elite) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Overload warning: the load is too high | Reduce the load. Microtek's troubleshooting for overload says to reduce the load and reset the UPS (the JM manual: overload above 110%). |
| oLd (shown as 000 oLd; icon glows steady, screen locked, Elite) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Overload shutdown: the UPS has switched off its output | Reduce the load and reset the front panel switch (OFF, then ON). |
| bLo (shown as 000 bLo; icon blinking, Elite) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Battery low warning | Recharge the battery when mains returns (Elite manual). The JM manual's low battery row also says to reduce the load. |
| bLo (shown as 000 bLo; icon glows steady, screen locked, Elite) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Battery low shutdown: the battery is discharged | Recharge the battery after mains returns, then reset the front ON/OFF switch to get output. |
| bHI (shown as 000 bHI) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Battery high shutdown: battery voltage too high | The manuals give no action for this code. Switch the UPS off and call Microtek authorised service. |
| SHt Ct | Elite 1500 LCD, JM SW 2500+ (LCD models) | Output short circuit (the UPS shuts its output) | Switch the power ON/OFF switch off to stop the beep, check the wiring, reduce the load and switch on again (JM manual). The Elite manual's short circuit row says: check the wiring, reduce the load and turn the reset switch on the front panel ON-OFF-ON. If the short stays, switch off and call Microtek authorised service. |
| otP (shown as 000 otP) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Over temperature protection | Let the UPS cool down; the JM manual says it resets to normal by itself, within 30 minutes. If it does not, reset the front switch (off, then on). If it still does not work, the JM manual says it is an internal problem: bypass the UPS with the rotary switch and call the service centre. |
| Cbt (shown as 220 Cbt) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Input circuit breaker trip | Check the MCB (circuit breaker) on the back panel and reset it. The Elite manual's CB trip row says: if it trips again, call the authorised service engineer to check for shorting or overload in the output circuit. |
| Lo (on the input side; the output side shows 220 V, 50 Hz or oFF) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Mains is on but its voltage or frequency is too low (out of the normal range). In backup mode the UPS runs on battery; in mains mode with the power switch off, the output shows oFF | The manuals give no action for this display. If your mains is actually normal, Microtek's troubleshooting says to check for a dead wall socket or loose AC input connections. |
| HI (on the input side; the output side shows 220 V, 50 Hz or oFF) | Elite 1500 LCD, JM SW 2500+ (LCD models) | Mains is on but its voltage or frequency is too high (out of the normal range). In backup mode the UPS runs on battery; in mains mode with the power switch off, the output shows oFF | The manuals give no action for this display. If your mains is actually normal, Microtek's troubleshooting says to check for a dead wall socket or loose AC input connections. |
| CHr (CHr on or FUL, mains mode) | Elite 1500 LCD | Charger status, shown in mains mode after the input voltage and frequency: CHr on, or CHr on / FUL (the manual says the 0.1 icon means the display shows CHr Ful). A clock icon shows the remaining charging time | Nothing to do. |
| oFF (on the output side) | Elite 1500 LCD | Output is off: standby (only the battery connected, ON/OFF switch off), or mains mode with the power switch off | Nothing to fix. |
| Mains LED flashing (mains is normal) | Heavy Duty VTurbo NEW (SW and DG) | The MCB (circuit breaker) at the back has tripped | Check the MCB on the back panel. If it is off, switch it on. If it trips again, call Microtek authorised service to check the output wiring for a short or overload. |
| Inverter or UPS LED glowing (mains is normal) | Heavy Duty VTurbo NEW (SW and DG) | The UPS is running on battery even though mains power is there: dead wall socket, or loose or wrong mains input connection | Check the wall socket and the mains input lead connection. |
| Overload LED glowing (red) (UPS mode, no output) | Heavy Duty VTurbo NEW (SW and DG) | Overload: too much load on the UPS | Reduce the load and reset the UPS. |
| Overload LED glowing (red) (short circuit) | Heavy Duty VTurbo NEW (SW and DG) | Short circuit in the output | Remove the load and reset the UPS. If it then works normally, the wiring may be wrong or a load faulty. If the short circuit stays, call authorised service. |
| Battery Low and Overload LEDs glowing (OTP) | Heavy Duty VTurbo NEW (SW and DG) | Over-temperature protection | Reduce the load and reset the UPS. Check that the fan is working; if the fan is not working normally, call authorised service. |
| Overload LED glowing (red) (other faults, alarm buzzing) | Heavy Duty VTurbo NEW (SW and DG) | Another fault (the Overload LED also flashes or glows for over charging and DC high) | Reset the UPS. If the alarm keeps buzzing, call authorised service. |
| Battery Low LED glowing (red) (UPS mode, no output) | Heavy Duty VTurbo NEW (SW and DG) | Battery has discharged | Recharge the battery when mains returns. Check the battery type selection pins on the back and set them to your battery type. |
| Charging LED flashing | Heavy Duty VTurbo NEW (SW and DG) | Battery is charging (normal) | Nothing to do. |
| Charging LED glowing steady | Heavy Duty VTurbo NEW (SW and DG) | Battery is fully charged (normal) | Nothing to do. |
| One 0.5 second beep (SW LED on) | Heavy Duty VTurbo NEW (SW and DG) | Battery low detected | The buzzer table gives no action. For a low battery, Microtek's troubleshooting table says to recharge the battery after mains comes back and check that the battery type pins on the back are set right. |
| No alarm (SW LED off) | Heavy Duty VTurbo NEW (SW and DG) | Battery low shutdown: the UPS has switched off because the battery is empty | The buzzer table gives no action. For a low battery, Microtek's troubleshooting table says to recharge the battery after mains comes back and check that the battery type pins on the back are set right. |
| Continuous alarm (SW LED on) | Heavy Duty VTurbo NEW (SW and DG) | CB trip (circuit breaker tripped) | The buzzer table gives no action. For an MCB trip, the troubleshooting table says to check the MCB at the back and switch it on if it is off. If it trips again, call authorised service to check the output circuit for a short or overload. |
| One beep (SW LED off) | Heavy Duty VTurbo NEW (SW and DG) | CB trip (circuit breaker tripped) | The buzzer table gives no action. For an MCB trip, the troubleshooting table says to check the MCB at the back and switch it on if it is off. If it trips again, call authorised service to check the output circuit for a short or overload. |
| Continuous alarm (SW LED off) | Heavy Duty VTurbo NEW (SW and DG) | One of these faults: mains mode burning risk protection (TX OTP), battery mode over-temperature (OTP), DC high voltage, output short, output low or output high | The buzzer table gives no action. Microtek's troubleshooting table says: for over-temperature, reduce the load, reset the UPS and check the fan; for a short circuit, remove the load and reset; for other faults, reset the UPS. If the alarm keeps buzzing, switch the UPS off and call authorised service. |
| One 0.5 second beep (SW LED off) | Heavy Duty VTurbo NEW (SW and DG) | Backfeed fault | The manual gives no fix for this. It warns that the UPS output must never be connected to a generator or the incoming mains supply. Switch the UPS off and call Microtek authorised service. |
Good to know
- On the Elite LCD, a blinking icon with oLd or bLo is a warning; a steady icon with the screen locked on that code means the UPS has shut down. The JM manual lists oLd and bLo for both warning and shutdown without describing the icon.
- The Elite LCD manual labels SHt Ct, otP and Cbt only as "Output Shutdown"; the JM SW 2500+ manual names them: output short circuit, over temperature and input breaker trip.
- On the JM, if an LED blinks in mains or backup mode, Microtek says it may be over temperature protection: wait for the unit to cool down. If it stays, reset the front switch (off, then on); if the problem persists it is an internal problem: bypass the UPS with the rotary switch and call the service centre.
- Microtek's manual says the Overload LED flashes or glows for overload, over-temperature (OTP), short circuit, over charging and DC high.
- On overload or a short circuit in UPS mode, the UPS goes into protection mode and shuts its output down.
- The buzzer table gives the buzzer and SW LED state for each fault but no action. The actions for the buzzer rows below come from the matching rows of Microtek's troubleshooting table.
- One beep with the SW LED off can mean a circuit breaker (CB) trip ("BZ beep once") or a backfeed fault ("BZ 0.5 sec beep one time"). Check the MCB at the back first; if it is on and the beep comes back, call authorised service.
- The manual warns that the UPS output must never be connected to a generator or the incoming mains supply: "this situation is far worse than a short-circuit". It also says to see the backfeed warning label on the UPS.
- If the backup time is short, Microtek says to check the battery water and charge the battery from mains for at least 8 to 12 hours. If backup is still short, get the battery checked by authorised service. (The JM SW 2500+ manual says at least 15 hours.)
- If the UPS trips often in backup mode, the load is too high: reduce the load and reset the UPS.
- If the UPS does not work at all, Microtek says to check the battery and mains connections; if those are fine it is an internal problem. Bypass the UPS (the rocker switch on the back selects UPS or Bypass mode) and call authorised service.
- On Heavy Duty VTurbo NEW models, to change from UPS mode to Inverter mode, press the power button for 2 seconds. A 500 ms press switches it on or off.
हिंदी में
Microtek LCD इन्वर्टर में कोड दिखता है: oLd (ओवरलोड), bLo (बैटरी कम), SHt Ct (शॉर्ट सर्किट), otP (ज़्यादा गर्म), Cbt (MCB गिरा)। Heavy Duty मॉडल में कोड नहीं आता, खराबी LED और बीप से पता चलती है।
- oLd आए तो लोड कम करें और आगे का स्विच बंद-चालू करें।
- otP आए तो UPS को ठंडा होने दें, यह अपने आप ठीक हो जाता है (JM मैनुअल: 30 मिनट तक)।
- बिजली ठीक है पर Mains LED झपके तो पीछे का MCB देखें। बंद हो तो चालू करें। फिर से गिरे तो सर्विस बुलाएं।
- Overload की लाल LED जले तो लोड कम करें और UPS रीसेट करें।
- Battery Low LED जले तो बिजली आने पर बैटरी चार्ज करें और पीछे के बैटरी टाइप पिन सही सेट करें।
- लगातार बीप बजे और रीसेट से न रुके तो UPS बंद करें और सर्विस बुलाएं। UPS खुद न खोलें, अंदर बिजली बंद होने पर भी तेज़ करंट रहता है।
Questions people ask
What does oLd mean on a Microtek inverter?
oLd means overload. If the icon blinks it is a warning; if it glows steady and the screen stays on oLd, the UPS has shut down. Reduce the load and reset the front switch (OFF, then ON).
What is bLo on a Microtek UPS?
bLo means battery low. A blinking icon is a warning; a steady icon means the UPS has shut down because the battery is discharged. Recharge the battery when mains returns, then reset the front ON/OFF switch.
What does SHt Ct mean on Microtek?
SHt Ct is an output short circuit. Microtek's JM manual says to switch the power switch off to stop the beep, check the wiring, reduce the load and switch on again. If the short stays, switch the UPS off and call Microtek authorised service.
Why is my Microtek inverter beeping continuously?
On Heavy Duty VTurbo NEW models, Microtek's buzzer table says a continuous alarm with the SW LED off means a fault: mains mode burning risk protection (TX OTP), battery mode over-temperature, DC high voltage, output short, output low or output high. With the SW LED on, it means a CB (circuit breaker) trip. Check the MCB at the back and reset the UPS; if the alarm keeps buzzing, switch it off and call Microtek authorised service.
Why is the Mains LED blinking on my Microtek inverter?
If mains power is normal and the Mains LED flashes, Microtek says the MCB at the back has tripped. Switch it back on. If it trips again, call authorised service to check the output wiring for a short or overload.
What does the red Overload LED mean on a Microtek inverter?
It flashes or glows when the UPS is overloaded, and also for a short circuit, over-temperature, over charging or DC high. Reduce the load and reset the UPS. If the short circuit stays, or the alarm keeps buzzing, call authorised service.
Why does my Microtek inverter give one beep?
Microtek's buzzer table lists three one-beep cases: a 0.5 second beep with the SW LED on means battery low was detected; one beep with the SW LED off means a CB (circuit breaker) trip; a 0.5 second beep with the SW LED off means a backfeed fault. For battery low, recharge the battery when mains returns. For the other two, check the MCB at the back; if it is on and the beep comes back, call authorised service.
Sources
- Microtek Heavy Duty VTurbo NEW pure sine wave (SW) UPS user manual, issue 05, 24/03/2025 (form QPN/003-442): LED indications and buzzer & SW LED table p.3, troubleshooting p.4, battery polarity caution p.4, safety instructions p.6, generator/backfeed warning p.7
- Microtek Heavy Duty VTurbo NEW Advanced Digital (DG) UPS user manual, issue 05, 24/03/2025 (form QPN/003-443): same LED and buzzer table p.3, troubleshooting p.4, battery polarity caution p.4, safety instructions p.6, generator/backfeed warning p.7
- Microtek Elite 1500 LCD 12V SW UPS user manual, issue 03, 25/04/2024 (form QPN/003-415): LCD display table p.3-5, troubleshooting p.6
- Microtek Jumbo UPS JM SW 2500+ /24V user manual, issue 02, 25/04/2024 (form QPN/003-320): LCD warning and fault table, troubleshooting