All LEDs (red, green, blue) Glow one after another for 1 second at power on
Normal start. Then the blue Power LED stays solid when power is available.
What to do: Nothing to do.
Delight NXT RO+UV+UF+TA
यह पेज Google ने मशीन से अनुवाद किया है। कोड का मतलब या सुरक्षा की बात पर शक हो तो English पेज पढ़ें।
Aquaguard purifiers do not show number codes. They show faults with lights: on Delight NXT the red Service LED and blue Power LED tell you about UV lamp, pump or water supply errors, and on Crest models a ring of LEDs blinks in set patterns, sometimes with a buzzer. Every row here is from Eureka Forbes' own user manuals for Sure from Aquaguard Delight NXT, Aquaguard Crest UV Hot and Zest RO+UV+MTDS+Hot / Crest UV. Eureka Forbes says user manuals come through a QR code with the product, and most current models' manuals are not on its website, so other Aquaguard models (for example Aura, Marvel, Enrich, Superb) may use different lights.
Safety: If a UV, solenoid valve, pump, sensor or EA fault shows, switch off the purifier and call Eureka Forbes authorised service. Eureka Forbes says that in case of any damage or incorrect functioning, contact an authorised service centre immediately. Do not drink water that comes out during flushing. Do not open the purifier yourself.
Light blinking? See what each Aquaguard light means and what to do first.
Normal start. Then the blue Power LED stays solid when power is available.
What to do: Nothing to do.
Delight NXT RO+UV+UF+TA
Normal: purification process.
What to do: Nothing to do.
Delight NXT RO+UV+UF+TA
Normal: the tank is filling.
What to do: Nothing to do.
Delight NXT RO+UV+UF+TA
Normal: tank full (storage).
What to do: Nothing to do.
Delight NXT RO+UV+UF+TA
UV lamp error.
What to do: Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.
Delight NXT RO+UV+UF+TA
Solenoid valve or pump error.
What to do: Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.
Delight NXT RO+UV+UF+TA
No input water (LPS error).
What to do: Check the water supply to the purifier. If water is coming, call service.
Delight NXT RO+UV+UF+TA
Normal: flushing. Do not drink the water that comes out during flushing.
What to do: Wait for flushing to end, or touch the centre to stop it.
Crest UV Hot; Zest RO+UV+MTDS+Hot / Crest UV
Normal: standby mode after the unit is not used for a while. (Crest UV Hot goes to sleep after 10 minutes of no use; its manual does not say which light shows.)
What to do: Touch the centre of the LED ring to wake it.
Zest RO+UV+MTDS+Hot / Crest UV
Normal: ready to dispense (Crest UV Hot: blue = ambient, yellow = warm, red = hot water).
What to do: Nothing to do.
Crest UV Hot; Zest RO+UV+MTDS+Hot / Crest UV
| Code | Model type | Meaning | What to do |
|---|---|---|---|
| UV lamp error (blue solid, red Service LED solid, green off) | Delight NXT RO+UV+UF+TA | UV lamp error | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| SV / pump error (blue solid, red Service LED flashing every 0.5 s, green off) | Delight NXT RO+UV+UF+TA | Solenoid valve (SV) or pump error | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| LPS error (blue Power LED flashing every 0.25 s, red and green off) | Delight NXT RO+UV+UF+TA | No input water (LPS error) | Check that the water supply to the purifier is on. If water is coming and the light still blinks, call Eureka Forbes service. |
| Temperature sensor fault (all LEDs blink red every 0.5 s) | Crest UV Hot | Temperature sensor fault | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| UV / LDR fault (all LEDs blink: on for 0.5 s, off for 3 s) | Crest UV Hot | UV lamp or LDR fault | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| SV fault (all LEDs blink: on, off, on for 0.5 s, then off for 3 s, repeating) | Crest UV Hot | Solenoid valve (SV) fault | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| EA fault (LEDs 2, 5 and 7 solid; LEDs 1 and 3 blink every 0.5 s) | Crest UV Hot | EA fault: both EA chips not connected, or the main board to junction board harness not connected | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| EA fault: combination cartridge (LEDs 2, 5 and 7 solid; LED 3 blinks every 0.5 s) | Crest UV Hot | EA fault on the combination cartridge (blue) | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| EA fault: active copper cartridge (LEDs 2, 5 and 7 solid; LED 1 blinks every 0.5 s) | Crest UV Hot | EA fault on the active copper cartridge with zinc booster (beige) | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| UV / LDR fault (all LEDs blink, buzzer beeps once every 3 s) | Zest RO+UV+MTDS+Hot / Crest UV | UV lamp or LDR fault | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| SV / pump fault (all LEDs blink, buzzer beeps twice every 3 s) | Zest RO+UV+MTDS+Hot / Crest UV | Solenoid valve (SV) or pump fault | Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier. |
| Filter first warning (LEDs 2, 3, 6 solid; the filter's LED blinks once every 3 s) | Zest RO+UV+MTDS+Hot / Crest UV | Filter end of life is nearing (first warning). LED 5 = combination cartridge, LED 1 = active copper with zinc booster. | Book a filter change with Eureka Forbes service. |
| Filter second warning (LEDs 2, 3, 6 solid; the filter's LED blinks twice every 3 s) | Zest RO+UV+MTDS+Hot / Crest UV | Filter second warning (end of life is near) | Book a filter change with Eureka Forbes service. |
| Filter end of life (LEDs 2, 3, 6 solid; the filter's LED blinks three times every 3 s) | Zest RO+UV+MTDS+Hot / Crest UV | Filter has reached end of life. Eureka Forbes says the unit is seized (stops) at end of life. | Call Eureka Forbes service to replace the filter cartridge. |
Aquaguard प्यूरीफ़ायर में नंबर वाले कोड नहीं आते, लाइट से खराबी पता चलती है। Delight NXT में लाल Service लाइट जले = UV लैंप खराब, लाल झपके = वाल्व या पंप खराब, नीली Power लाइट तेज़ झपके = पानी नहीं आ रहा। Crest में LED का गोला अलग-अलग तरह से झपकता है।
Aquaguard purifiers in Eureka Forbes' manuals have no number codes. They show faults with lights: on Delight NXT, a red Service LED (UV lamp, valve or pump error) or a fast-blinking blue Power LED (no input water); on Crest, patterns on the LED ring, sometimes with a buzzer.
On Sure from Aquaguard Delight NXT, a solid red Service LED (blue solid, green off) means a UV lamp error. A red Service LED blinking every 0.5 s means a solenoid valve or pump error. Switch off and call Eureka Forbes service.
On Delight NXT, a green Tank Full LED blinking every 0.5 s continuously means the tank is filling, and blinking for 6 seconds means purification is running. Both are normal. Solid green means the tank is full.
On Zest / Crest UV, all LEDs blinking with the buzzer means a fault: one beep every 3 seconds is a UV lamp or LDR fault, two beeps every 3 seconds is a solenoid valve or pump fault. Switch off and call Eureka Forbes service.