Voltas AC Error Codes: E1, E2, E5, E6, dF, EC and Inverter Table

By FaultDecode · Checked against Voltas' official documents · Updated · How we check

53 Voltas codes on this page.

Every row here comes from a Voltas user manual downloaded from Voltas's service portal. Voltas prints different tables in different manuals, and the same code can mean different things. In the "conventional series" table and the window AC manuals, E1 is a room sensor fault and E2 a coil sensor fault. In the inverter table (SAC 183V WZJ split, WAC 183V ADI window) and the Wi-Fi code list, E1 is an indoor fan fault and E2 is indoor fan zero-crossing. The SAC 123 Vectra Elegant and SAC 125V DZX manuals print both the conventional table and the Wi-Fi list on the same page without saying which applies to which unit, so check your own manual. E6 is a zero crossing error in the conventional table, an indoor-outdoor communication fault on the SAC 183V WZJ, and a main board to drive board communication fault on the WAC 183V ADI window AC.

Safety: Voltas's manual says: don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. For EC (gas leak detection) or any fault that keeps coming back, switch off and call Voltas customer care.

How to see the code

  1. Find your model name on the indoor unit sticker or the manual cover (for example SAC 123 Vectra Elegant, SAC 183V WZJ, WAC 173 DZA).
  2. Read the code on the indoor unit display.
  3. On the inverter models, you can also count the outdoor unit light flashes; the count is given next to each code.
  4. Match the code in the rows for your type of AC. If your model is not listed, check your own manual on the Voltas service portal.

Only a blinking light? Use the Voltas blink decoder: tap once per flash and see the code.

How to check the error code on other AC brands

What the Voltas lights mean

Cool LED (window AC) Blinks after you switch on in Cool mode

Normal: the compressor waits about 3 minutes before it starts. The Cool LED blinks during this delay.

What to do: Wait about 3 minutes. Not a fault.

Window AC: WAC 123V ADS, WAC 183 Vectra Elegant, WAC 123 Vectra Platina, WAC 123V Vertis Platina

Running indicator Flashes

Defrosting. The running indicator lights up when the AC runs and flashes during defrosting.

What to do: Wait for defrost to finish. Not a fault.

Split AC: SAC 123V CZTT (R32)

Whole LED panel All lights blink, with two beeps

Test mode is on. It starts when the LAMP key on the remote is pressed 8 times in Cooling mode at 16°C or 17°C with high fan (Voltas's full load / half load cooling test procedure).

What to do: Switch the power off and on: Voltas says a power reset takes the AC out of test mode back to normal running.

DC inverter models: SAC 182FS Emerald, SAC 143INV Breezia Emerald, 123INV Vectra Emerald, EU 243INVHC Vectra Zenith, SAC 183V MZSC, SAC 183V MZJ3, WAC 123V ADS, WAC 123V Vertis Platina

Remote display Shows a blinking Lb

The remote's batteries need replacing (Voltas: Type 6 remote only).

What to do: Replace both batteries with new ones of the same type.

Type 6 remote: SAC 182FS Emerald, EU 243INVHC Vectra Zenith, SAC 183INV Vertis Leatherette

Voltas AC error code list

CodeModel typeMeaningWhat to do
E1 (indoor unit) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Room sensor short or open · full fix E1 on a Voltas AC depends on the model. Voltas's "conventional series" table and window AC manuals say E1 shows when the room sensor is short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E1 is an indoor fan fault, and the outdoor light flashes 26 times. Both need a technician.
E2 (indoor unit) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor coil sensor short or open · full fix E2 on a Voltas AC depends on the model. Voltas's "conventional series" table says E2 shows when the indoor coil sensor is short or open, and the window AC manuals say E2 is a coil sensor short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E2 means indoor fan zero-crossing detection abnormal, and the outdoor light flashes 27 times. Both need a technician.
dF (indoor unit) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor defrost protection error in cool and dry mode · full fix dF on a Voltas AC relates to defrost. Voltas's conventional series table says dF indicates an indoor unit defrost protection error in cool and dry mode. The window AC manuals say dF is for defrost and occurs in cool mode and dry mode. In heat mode the matching code is HF (outdoor or condenser coil defrost). Voltas does not give a home fix for dF; if it keeps showing, call Voltas customer care.
E5 (indoor unit) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Fan motor error · full fix E5 on a Voltas split AC indicates a fan motor error. It is listed for the indoor unit in the "Error code for conventional series models" table in Voltas's user manuals (for example SAC 123 Vectra Elegant and SAC 125V DZX). The Voltas inverter table (SAC 183V WZJ, WAC 183V ADI) does not list E5. There is no home fix for a fan motor error; call Voltas customer care.
E6 (indoor unit) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Zero crossing error · full fix E6 on a Voltas AC depends on the model. In the "conventional series" split AC table, Voltas says E6 indicates a zero crossing error. On the SAC 183V WZJ inverter split AC, E6 is an indoor and outdoor machine communication fault. On the WAC 183V ADI inverter window AC, E6 is a main board and drive board communication fault. On both inverter models the outdoor light flashes 2 times. All need a technician.
EC (selected models only) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Gas leak detection · full fix EC on a Voltas split AC means gas leak detection. Voltas's conventional series error table lists EC for the indoor unit as "Gas Leak Detection (applicable for selected models)", so not every Voltas AC has it. There is no home fix. Switch off the AC and call Voltas customer care (9650694555 or 1860 599 4555).
HP (heat mode) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor coil high temperature protection in heat mode —
E3 (outdoor unit) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Outdoor coil sensor short or open · full fix E3 on a Voltas AC depends on the model. In the "conventional series" table, E3 shows when the outdoor (ODU) coil sensor is short or open. The window AC manuals say E3 shows when the condenser coil sensor is short or open in heat mode. On inverter models (SAC 183V WZJ, WAC 183V ADI) and in the Wi-Fi list, E3 is an indoor coil fault and sensor fault, and the outdoor light flashes 28 times. All need a technician.
HF (outdoor unit, heat mode) Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Outdoor defrost protection error in heat mode —
EE Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor machine EE fault —
E1 Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor fan fault · full fix E1 on a Voltas AC depends on the model. Voltas's "conventional series" table and window AC manuals say E1 shows when the room sensor is short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E1 is an indoor fan fault, and the outdoor light flashes 26 times. Both need a technician.
E2 Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor fan zero-crossing detection abnormal · full fix E2 on a Voltas AC depends on the model. Voltas's "conventional series" table says E2 shows when the indoor coil sensor is short or open, and the window AC manuals say E2 is a coil sensor short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E2 means indoor fan zero-crossing detection abnormal, and the outdoor light flashes 27 times. Both need a technician.
E3 Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor coil fault and sensor fault · full fix E3 on a Voltas AC depends on the model. In the "conventional series" table, E3 shows when the outdoor (ODU) coil sensor is short or open. The window AC manuals say E3 shows when the condenser coil sensor is short or open in heat mode. On inverter models (SAC 183V WZJ, WAC 183V ADI) and in the Wi-Fi list, E3 is an indoor coil fault and sensor fault, and the outdoor light flashes 28 times. All need a technician.
E4 Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Indoor ambient temperature sensor fault —
E9 (test mode only) Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals) Wi-Fi module fault (seen while pressing the emergency switch and powering on the indoor unit) —
E1 Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter) Room sensor short or open · full fix E1 on a Voltas AC depends on the model. Voltas's "conventional series" table and window AC manuals say E1 shows when the room sensor is short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E1 is an indoor fan fault, and the outdoor light flashes 26 times. Both need a technician.
E2 Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter) Coil sensor short or open · full fix E2 on a Voltas AC depends on the model. Voltas's "conventional series" table says E2 shows when the indoor coil sensor is short or open, and the window AC manuals say E2 is a coil sensor short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E2 means indoor fan zero-crossing detection abnormal, and the outdoor light flashes 27 times. Both need a technician.
E3 (heat mode) Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter) Condenser coil sensor short or open in heat mode · full fix E3 on a Voltas AC depends on the model. In the "conventional series" table, E3 shows when the outdoor (ODU) coil sensor is short or open. The window AC manuals say E3 shows when the condenser coil sensor is short or open in heat mode. On inverter models (SAC 183V WZJ, WAC 183V ADI) and in the Wi-Fi list, E3 is an indoor coil fault and sensor fault, and the outdoor light flashes 28 times. All need a technician.
HF (heat mode) Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter) Condenser coil defrost in heat mode —
dF (cool and dry mode) Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter) Defrost; occurs in cool mode and dry mode · full fix dF on a Voltas AC relates to defrost. Voltas's conventional series table says dF indicates an indoor unit defrost protection error in cool and dry mode. The window AC manuals say dF is for defrost and occurs in cool mode and dry mode. In heat mode the matching code is HF (outdoor or condenser coil defrost). Voltas does not give a home fix for dF; if it keeps showing, call Voltas customer care.
EE (outdoor light flashes 25) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor machine EE fault —
E1 (outdoor light flashes 26) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor fan fault · full fix E1 on a Voltas AC depends on the model. Voltas's "conventional series" table and window AC manuals say E1 shows when the room sensor is short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E1 is an indoor fan fault, and the outdoor light flashes 26 times. Both need a technician.
E2 (outdoor light flashes 27) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor fan zero-crossing detection abnormal · full fix E2 on a Voltas AC depends on the model. Voltas's "conventional series" table says E2 shows when the indoor coil sensor is short or open, and the window AC manuals say E2 is a coil sensor short or open. On inverter models (SAC 183V WZJ split, WAC 183V ADI window) and in the Wi-Fi error list, E2 means indoor fan zero-crossing detection abnormal, and the outdoor light flashes 27 times. Both need a technician.
E3 (outdoor light flashes 28) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor coil fault and sensor fault · full fix E3 on a Voltas AC depends on the model. In the "conventional series" table, E3 shows when the outdoor (ODU) coil sensor is short or open. The window AC manuals say E3 shows when the condenser coil sensor is short or open in heat mode. On inverter models (SAC 183V WZJ, WAC 183V ADI) and in the Wi-Fi list, E3 is an indoor coil fault and sensor fault, and the outdoor light flashes 28 times. All need a technician.
E4 (outdoor light flashes 29) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor ambient temperature sensor fault —
E0 (outdoor light flashes 1) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor EE fault —
F1 (outdoor light flashes 4) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor starting abnormal (phase failure, reverse) —
F2 (outdoor light flashes 5) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor out-of-step fault —
F3 (outdoor light flashes 6) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) IPM module fault —
F4 (outdoor light flashes 7) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor shell roof fault / protection —
F5 (outdoor light flashes 8) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Discharge temperature sensor fault —
F6 (outdoor light flashes 9) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Suction temperature sensor fault —
F7 (outdoor light flashes 10) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor coil temperature sensor fault —
F8 (outdoor light flashes 11) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor ambient temperature sensor fault —
F9 (outdoor light flashes 12) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor DC fan fault —
P1 (outdoor light flashes 13) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor machine AC current protection (WAC 183V ADI table: AC current / power overload protection) —
P2 (outdoor light flashes 14) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor phase current protection —
P3 (outdoor light flashes 15) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor unit AC voltage too high or too low protection —
P4 (outdoor light flashes 16) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) DC voltage too high or too low protection —
P5 (outdoor light flashes 17) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) IPM over-high temperature protection —
P6 (outdoor light flashes 18) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Discharge temperature overheat protection —
P7 (outdoor light flashes 19) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Cooling: indoor coil anti-freezing protection —
P8 (outdoor light flashes 20) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Cooling: outdoor coil overheat protection —
P9 (outdoor light flashes 21) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Heating: indoor coil overheat protection —
PC (outdoor light flashes 22) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Cooling: outdoor ambient temperature too low protection —
PH (outdoor light flashes 23) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Heating: outdoor ambient temperature too high protection —
L1 (outdoor light flashes 31) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Drive bus voltage too high protection —
L2 (outdoor light flashes 32) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Drive bus voltage too low protection —
L3 (outdoor light flashes 33) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Drive phase current overload fault —
L4 (outdoor light flashes 34) Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Phase current sampling abnormal —
E6 (outdoor light flashes 2) Inverter split AC, SAC 183V WZJ Indoor and outdoor machine communication fault · full fix E6 on a Voltas AC depends on the model. In the "conventional series" split AC table, Voltas says E6 indicates a zero crossing error. On the SAC 183V WZJ inverter split AC, E6 is an indoor and outdoor machine communication fault. On the WAC 183V ADI inverter window AC, E6 is a main board and drive board communication fault. On both inverter models the outdoor light flashes 2 times. All need a technician.
E6 (outdoor light flashes 2) Inverter window AC, WAC 183V ADI Main board and drive board communication fault · full fix E6 on a Voltas AC depends on the model. In the "conventional series" split AC table, Voltas says E6 indicates a zero crossing error. On the SAC 183V WZJ inverter split AC, E6 is an indoor and outdoor machine communication fault. On the WAC 183V ADI inverter window AC, E6 is a main board and drive board communication fault. On both inverter models the outdoor light flashes 2 times. All need a technician.
E8 (no outdoor flash count) Inverter split AC, SAC 183V WZJ only Outdoor communication fault —

No code, but a problem?

Good to know

हिंदी में

Voltas के अलग-अलग मॉडल में एक ही कोड का मतलब अलग हो सकता है। सामान्य स्प्लिट और विंडो AC में E1 कमरे का सेंसर और E2 कॉइल सेंसर है। इन्वर्टर मॉडल में E1 अंदर के पंखे की खराबी है।

  1. पहले AC के स्टिकर या मैनुअल से मॉडल का नाम देखें।
  2. कोड का मतलब नीचे उसी तरह के AC की लाइन में देखें।
  3. EC (गैस लीक) आए तो AC बंद करें और Voltas कस्टमर केयर बुलाएं।
  4. AC खुद न खोलें। Voltas कस्टमर केयर: 9650694555 या 1860 599 4555।

Questions people ask

What is E2 error in a Voltas AC?

In the Voltas conventional series table, E2 means the indoor coil sensor is short or open. On window ACs it is a coil sensor short or open. In the inverter table and the Wi-Fi list, E2 means indoor fan zero-crossing detection abnormal.

What is E5 error in a Voltas AC?

In the Voltas conventional series table, E5 indicates a fan motor error. The Voltas inverter table does not list E5.

What is E6 error in a Voltas AC?

In the conventional series table, E6 indicates a zero crossing error. On the SAC 183V WZJ inverter split it is an indoor and outdoor machine communication fault, and on the WAC 183V ADI inverter window AC a main board and drive board communication fault. On both inverter models the outdoor light flashes 2 times.

What is dF on a Voltas AC?

In the conventional series table, dF indicates an indoor defrost protection error in cool and dry mode. Voltas's window AC manuals say dF is for defrost and occurs in cool and dry mode.