हिंदी

Voltas AC blinking light codes

By FaultDecode · From Voltas' official manual · Updated · How we check

No code on the display, only a blinking light? Some Voltas models also show the fault as a number of flashes. Count them and pick the light below. Every row comes from the Voltas AC error code list. Other brand? See AC light blinking on every brand.

Safety: Voltas's manual says: don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. For EC (gas leak detection) or any fault that keeps coming back, switch off and call Voltas customer care.

How to count the flashes

  1. On the inverter models, you can also count the outdoor unit light flashes; the count is given next to each code.

Outdoor light flashes

FlashesCodeModel typeMeaning
1 E0 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor EE fault
2 E6 Inverter split AC, SAC 183V WZJ Indoor and outdoor machine communication fault · full fix
2 E6 Inverter window AC, WAC 183V ADI Main board and drive board communication fault · full fix
4 F1 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor starting abnormal (phase failure, reverse)
5 F2 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor out-of-step fault
6 F3 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) IPM module fault
7 F4 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor shell roof fault / protection
8 F5 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Discharge temperature sensor fault
9 F6 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Suction temperature sensor fault
10 F7 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor coil temperature sensor fault
11 F8 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor ambient temperature sensor fault
12 F9 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor DC fan fault
13 P1 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor machine AC current protection (WAC 183V ADI table: AC current / power overload protection)
14 P2 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Compressor phase current protection
15 P3 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Outdoor unit AC voltage too high or too low protection
16 P4 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) DC voltage too high or too low protection
17 P5 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) IPM over-high temperature protection
18 P6 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Discharge temperature overheat protection
19 P7 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Cooling: indoor coil anti-freezing protection
20 P8 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Cooling: outdoor coil overheat protection
21 P9 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Heating: indoor coil overheat protection
22 PC Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Cooling: outdoor ambient temperature too low protection
23 PH Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Heating: outdoor ambient temperature too high protection
25 EE Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor machine EE fault
26 E1 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor fan fault · full fix
27 E2 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor fan zero-crossing detection abnormal · full fix
28 E3 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor coil fault and sensor fault · full fix
29 E4 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Indoor ambient temperature sensor fault
31 L1 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Drive bus voltage too high protection
32 L2 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Drive bus voltage too low protection
33 L3 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Drive phase current overload fault
34 L4 Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) Phase current sampling abnormal

Other lamp states

Not every blink is a fault code. Voltas' manuals also describe these lamp states:

Cool LED (window AC) Blinks after you switch on in Cool mode

Normal: the compressor waits about 3 minutes before it starts. The Cool LED blinks during this delay.

What to do: Wait about 3 minutes. Not a fault.

Window AC: WAC 123V ADS, WAC 183 Vectra Elegant, WAC 123 Vectra Platina, WAC 123V Vertis Platina

Running indicator Flashes

Defrosting. The running indicator lights up when the AC runs and flashes during defrosting.

What to do: Wait for defrost to finish. Not a fault.

Split AC: SAC 123V CZTT (R32)

Whole LED panel All lights blink, with two beeps

Test mode is on. It starts when the LAMP key on the remote is pressed 8 times in Cooling mode at 16°C or 17°C with high fan (Voltas's full load / half load cooling test procedure).

What to do: Switch the power off and on: Voltas says a power reset takes the AC out of test mode back to normal running.

DC inverter models: SAC 182FS Emerald, SAC 143INV Breezia Emerald, 123INV Vectra Emerald, EU 243INVHC Vectra Zenith, SAC 183V MZSC, SAC 183V MZJ3, WAC 123V ADS, WAC 123V Vertis Platina

Remote display Shows a blinking Lb

The remote's batteries need replacing (Voltas: Type 6 remote only).

What to do: Replace both batteries with new ones of the same type.

Type 6 remote: SAC 182FS Emerald, EU 243INVHC Vectra Zenith, SAC 183INV Vertis Leatherette

हिंदी में

डिस्प्ले पर कोड नहीं, सिर्फ़ बत्ती झपक रही है? बत्ती कितनी बार झपकती है, उसे गिनें। झपकने के बाद थोड़ा रुकती है, फिर दोबारा शुरू होती है। दो रुकावटों के बीच की गिनती ही आपका कोड है।

  1. ऊपर सही बत्ती चुनें और हर झपक पर बड़ा बटन दबाएं, या गिनती लिखें।
  2. एक ही गिनती के अलग मॉडल पर अलग मतलब हो सकते हैं। यूनिट के स्टिकर पर मॉडल देखें।
  3. मशीन को दीवार के स्विच से बंद करें। कोड और झपकने की गिनती लिख लें, फिर अधिकृत सर्विस को बुलाएं। यूनिट खुद न खोलें।

Questions people ask

How do I count Voltas AC light blinks?

Watch the light for a full cycle: it flashes a number of times, pauses, then repeats. Count the flashes between two pauses. Count two or three cycles to be sure.

The same number of flashes shows two different faults. Which one is mine?

Voltas uses different tables for different model types. Check the model name on the unit sticker and use the row for your model type.

Can I fix a blinking light fault myself?

Switch off the unit at the wall and note the code and the number of flashes. Voltas's manual says: don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. For EC (gas leak detection) or any fault that keeps coming back, switch off and call Voltas customer care.

Sources

Last checked:

↑