| 1 | E0 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Outdoor EE fault |
| 2 | E6 | Inverter split AC, SAC 183V WZJ | Indoor and outdoor machine communication fault · full fix |
| 2 | E6 | Inverter window AC, WAC 183V ADI | Main board and drive board communication fault · full fix |
| 4 | F1 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Compressor starting abnormal (phase failure, reverse) |
| 5 | F2 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Compressor out-of-step fault |
| 6 | F3 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | IPM module fault |
| 7 | F4 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Compressor shell roof fault / protection |
| 8 | F5 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Discharge temperature sensor fault |
| 9 | F6 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Suction temperature sensor fault |
| 10 | F7 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Outdoor coil temperature sensor fault |
| 11 | F8 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Outdoor ambient temperature sensor fault |
| 12 | F9 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Outdoor DC fan fault |
| 13 | P1 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Outdoor machine AC current protection (WAC 183V ADI table: AC current / power overload protection) |
| 14 | P2 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Compressor phase current protection |
| 15 | P3 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Outdoor unit AC voltage too high or too low protection |
| 16 | P4 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | DC voltage too high or too low protection |
| 17 | P5 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | IPM over-high temperature protection |
| 18 | P6 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Discharge temperature overheat protection |
| 19 | P7 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Cooling: indoor coil anti-freezing protection |
| 20 | P8 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Cooling: outdoor coil overheat protection |
| 21 | P9 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Heating: indoor coil overheat protection |
| 22 | PC | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Cooling: outdoor ambient temperature too low protection |
| 23 | PH | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Heating: outdoor ambient temperature too high protection |
| 25 | EE | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Indoor machine EE fault |
| 26 | E1 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Indoor fan fault · full fix |
| 27 | E2 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Indoor fan zero-crossing detection abnormal · full fix |
| 28 | E3 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Indoor coil fault and sensor fault · full fix |
| 29 | E4 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Indoor ambient temperature sensor fault |
| 31 | L1 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Drive bus voltage too high protection |
| 32 | L2 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Drive bus voltage too low protection |
| 33 | L3 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Drive phase current overload fault |
| 34 | L4 | Inverter AC (SAC 183V WZJ split, WAC 183V ADI window) | Phase current sampling abnormal |