How to reset an AC
Quick answer
The manuals describe a few different resets. For an AC that is acting erratically or not responding, Carrier says disconnect the power, reconnect it and press ON/OFF on the remote; Voltas and Lloyd (when the remote gets no response) say pull out the plug and reinsert it, Lloyd after about 3 minutes; Daikin says turn the circuit breaker off and on again (for malfunction from lightning or radio waves). If an error code or flashing lamps appear on a Carrier, wait about 10 minutes first; it may clear by itself. To reset the remote: the LG remote has a Reset button, and the Lloyd new-remote handset resets to factory settings when you take out the batteries and press any key. Filter reminders are reset separately (Carrier: LED button 4 times or MANUAL CONTROL 3 times; Lloyd new-remote models: TURBO for 5 seconds). If the error comes back, call service.
Safety: Samsung says do not turn the AC off with the circuit breaker while it is operating: switching it off and on at the breaker may cause a spark and result in electric shock or fire. Do not touch the circuit breaker with wet hands. Do not keep resetting the AC if the power cord is damaged or unusually warm, you smell burning, the unit makes loud or abnormal sounds, the fuse blows or the breaker trips often, or water gets into or leaks from the unit: turn it off, unplug it and contact service (Carrier, Panasonic). If an error code or blinking lamp comes back after a restart, note it and call service. Do not open the unit.
Jump to: Power resetAuto RestartRemote resetFilter reminderOther resetsCall serviceRelated codes
1. Power reset (AC erratic or not responding to the remote)
- Carrier: If operation is erratic or unpredictable, or the unit is unresponsive (interference from cell phone towers and remote boosters may cause this), disconnect the power, then reconnect it, and press ON/OFF on the remote to restart operation. If the problem continues, contact a local dealer or customer service with a description of the fault and your model number.
- Voltas: If abnormal or frequent function switching stops the remote from working, pull out the plug and reinsert it.
- Lloyd: If the indoor unit does not respond to the remote and the unit is severely interfered with (the manual gives static electricity and voltage as examples), pull out the plug, reinsert it after about 3 minutes, then turn the unit on again.
- Daikin: The AC may malfunction with lightning or radio waves. Turn off the circuit breaker, turn it on again and try operating the AC with the remote.
- Wait 3 minutes before turning back on: Lloyd says if the unit was restarted immediately after stopping, wait 3 minutes and turn it on again. Carrier: the unit has a 3-minute protection feature and cannot be restarted within three minutes of being turned off. LG says turn the AC off when a power failure occurs; when power is restored, wait 3 minutes, then turn it on.
From: Carrier Xcel Indus manual; Voltas Vectra Elegant manual; Lloyd split AC manual; Daikin inverter split AC manual; LG split AC manual
2. After a power cut: Auto Restart
- LG: Auto Restart brings back the previous settings when the AC is turned on again after a power failure. It is set when you first use the AC. To cancel or set it, open the up-down vane (Type 1) or front cover (Type 2), press and hold the Power button on the indoor unit for 6 seconds and release it when it beeps twice; the lamp flashes (twice when cancelling), and this repeats 4 times. LG notes the feature may change depending on the model.
- LG, careful with the Power button: Holding it for 3 to 5 seconds instead of 6 starts test operation: strong cooling for 18 minutes, then the AC returns to factory default settings. Releasing it before the four beeps may disable other features that are set.
- Carrier: If the unit loses power, it restarts with the prior settings once power is restored.
- Panasonic: When power returns after a power failure, operation restarts by itself after a while in the previous mode and airflow direction. This does not apply when TIMER is set.
- Daikin, timer: Set the timer again after the circuit breaker has been turned off, after a power failure, or after replacing the remote batteries.
From: LG split AC manual; Carrier Xcel Indus manual; Panasonic CS-XS UKY manual; Daikin inverter split AC manual
3. Reset the remote
- LG: The remote in LG manual MFL72020502 has a Reset button that resets the wireless remote control settings (LG notes some functions depend on the model). LG also says to use it (or reinsert the battery) to set the current time.
- Lloyd (new-remote handset): Remove the batteries and press any key without them. When you put the batteries back, the remote restarts in factory mode: all icons glow for 2 seconds, then it goes to clock setting mode and then to OFF. Saved settings such as MY MODE, timer and preset are erased.
For a remote that does not work at all, see the AC remote not working page.
4. Reset the filter cleaning reminder
- Carrier (CL or nF reminder, where fitted): Press the LED button on the remote 4 times, or press the MANUAL CONTROL button 3 times. If you do not reset it, the reminder flashes again when you restart the unit.
- Lloyd split, new remote (selected models): After cleaning the filter, press TURBO for 5 seconds to reset the reminder.
Clean the filter first: the reset only clears the reminder. Steps are on the AC filter cleaning page.
5. Other resets in the manuals
- Carrier louver out of sync: Do not move the louver by hand. If it goes out of sync, turn off the unit and unplug it for a few seconds, then restart it. This resets the louver.
- LG AI learned information: Open the vane or front cover, press and hold the Power button on the indoor unit for more than 13 seconds and release it after four beeps. The learned living area information is deleted.
6. When a reset is not enough
- Carrier, error code or flashing lamps: Wait about 10 minutes; the problem may resolve itself. If not, disconnect the power, connect it again and turn the unit on. If the problem persists, disconnect the power and contact your nearest customer service center.
- Panasonic: For certain errors you may restart the unit for limited operation, but if the problem continues, consult the authorised dealer with the error code.
- Daikin (operation stops, OPERATION lamp blinking): Clean dirty air filters. If something blocks the air inlet or outlet, stop operation, turn off the circuit breaker, remove the obstruction and restart with the remote. If the lamp stops blinking there is no malfunction; if it is still blinking, check the error code and consult the service centre.
From: Carrier Xcel Indus manual; Panasonic CS-XS UKY manual; Daikin inverter split AC manual
Reminders you can reset
- Carrier CL (Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)): Filter cleaning reminder after 240 hours of use (not a fault)
- Carrier nF (Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)): Filter replacement reminder after 2,880 hours of use (not a fault)
- Lloyd CL (Inverter split): Filter cleaning reminder (selected models)
हिंदी में
AC अजीब तरह से चले या जवाब न दे तो मैनुअल पावर रीसेट बताते हैं: Carrier बिजली काटकर फिर जोड़ने और रिमोट से ON/OFF दबाने को कहता है, Voltas प्लग निकालकर फिर लगाने को, Lloyd लगभग 3 मिनट बाद प्लग लगाने को, और Daikin MCB बंद-चालू करने को (बिजली कड़कने या रेडियो तरंगों से गड़बड़ी पर)। रिमोट और फ़िल्टर रिमाइंडर का रीसेट अलग होता है। कोड बार-बार आए तो सर्विस बुलाएँ।
- Carrier: बिजली काटें, फिर जोड़ें, रिमोट से ON/OFF दबाएँ।
- Lloyd: प्लग निकालें, लगभग 3 मिनट बाद लगाकर AC चालू करें। Voltas: प्लग निकालकर फिर लगाएँ।
- बंद करने के तुरंत बाद चालू न करें; 3 मिनट रुकें (Lloyd, Carrier)।
- LG रिमोट: Reset बटन। Lloyd रिमोट: बैटरी निकालकर कोई भी बटन दबाएँ, फिर बैटरी लगाएँ (सेव सेटिंग मिट जाती हैं)।
- फ़िल्टर रिमाइंडर: Carrier में LED बटन 4 बार या MANUAL CONTROL 3 बार; Lloyd (नए रिमोट वाले कुछ मॉडल) में TURBO 5 सेकंड। पहले फ़िल्टर साफ़ करें।
- LG: Auto Restart के लिए Power बटन 6 सेकंड दबाएँ। 3-5 सेकंड दबाने पर टेस्ट ऑपरेशन चलता है (18 मिनट तेज़ ठंडी हवा), फिर फ़ैक्टरी डिफ़ॉल्ट सेटिंग आ जाती है।
- Carrier में कोड या ब्लिंक दिखे तो लगभग 10 मिनट रुकें, फिर बिजली काटकर जोड़ें। फिर भी आए तो कोड नोट करें और सर्विस बुलाएँ। Samsung: चलते AC को MCB से बंद न करें।
Questions people ask
How do I reset my AC?
For an AC that is erratic or not responding: Carrier says disconnect and reconnect the power and press ON/OFF on the remote, Voltas says pull out and reinsert the plug, Lloyd says reinsert the plug after about 3 minutes, and Daikin says turn the circuit breaker off and on (for malfunction from lightning or radio waves).
How do I reset the AC remote?
The remote in LG manual MFL72020502 has a Reset button. The Lloyd new-remote handset resets to factory settings when you remove the batteries, press any key, then put the batteries back; saved settings are erased.
How do I reset the filter clean light on my AC?
Carrier (where the reminder is fitted): press the LED button on the remote 4 times or the MANUAL CONTROL button 3 times. Lloyd split with the new remote (selected models): press TURBO for 5 seconds. Clean the filter first.
Will my AC remember settings after a power cut?
LG and Carrier have Auto Restart, which brings back the previous settings. Panasonic restarts in the previous mode and airflow direction, but not when TIMER is set. Daikin says set the timer again after a power failure.
Does resetting fix an AC error code?
Sometimes. Carrier says wait about 10 minutes, then disconnect and reconnect the power; if the code persists, disconnect the power and contact service. Panasonic says some errors allow a restart for limited operation, but if the problem persists, consult the authorised dealer with the error code. Daikin says if the OPERATION lamp is still blinking after restarting, check the error code and consult the service centre.
Sources
- LG India split air conditioner owner's manual MFL72020502 (Rev.01, 2023): current time p.13, Reset button p.15, Auto Restart and manual operation notes pp.25-26, resetting learned information p.26, power failure p.39 (LG India support page, Manuals section)
- Daikin India inverter split AC operation and installation manual 3P719813-1Z: timer after power failure p.9, OPERATION lamp blinking and abnormal functioning p.16 (printed page numbers)
- Lloyd split AC user manual, new remote (Havells, 2025): factory reset PDF p.16, remote reset p.34, filter reminder reset p.40, malfunction analysis p.57-58
- Carrier Xcel Indus split AC user manual (2024): Auto-Restart and filter reminder p.8, louver reset p.9, filter reminders p.13, safety and 3-minute protection p.14, erratic operation p.15, error codes and troubleshooting p.17
- Voltas SAC 123 Vectra Elegant split AC user manual: troubleshooting (pull out the plug and reinsert) PDF p.19
- Panasonic CS-XS12UKY / XS18UKY / XS24UKY series operating instructions (Panasonic India): Auto Restart Control p.7, error codes and restart p.9
- Samsung split AC user manual DB68-09629F-01 (AR**AY*Y*** / AR**AY*Z*** models, 2021): circuit breaker safety p.5
Last checked: