Quick answer
Most AC remotes use the same picture language. Snowflake = Cool, water drop = Dry (removes moisture), fan or propeller = Fan only (no cooling), sun = Heat (heat-cool models only), A or Ai = Auto. Bars next to a fan icon = fan speed. Moon = Sleep, clock with ON or OFF = timer, a wavy louver = swing, bulb or Lamp = indoor display light, padlock = child lock, battery = remote battery level. Turbo cools fast at high fan; Eco or Saver sets 24°C. Brand extras differ: Lloyd's 6-in-1 shows C1 to C5 (40% to 110% capacity), and the indoor unit can show short letters like dg (DG mode) or Ic (Ice Clean) that are not errors.
Jump to: Mode symbols (the same on most remotes)Other common symbols on an AC remoteLloyd remote: 6-in-1, Constant, My Mode, DG and other iconsLloyd hidden button combinationsLetters on the indoor unit display that are not errorsIndoor unit lamps (Voltas and Carrier)Panasonic remote and indoor lamps (CS-XS UKY series)Samsung remote and indoor display (AR**AY models)Daikin remote buttons (inverter split, 3P719813 manual)Lost remote? Use the button on the indoor unitRelated codes
Mode symbols (the same on most remotes)
- Snowflake, Cool: Normal cooling. You can set 16 to 30°C on Lloyd and Voltas. If you switch off and on from the remote, a lower setting comes back at 24°C (Lloyd: 16 to 23°C goes to 24°C, 24°C or above stays; Voltas: minimum 24°C). Carrier says its default is 24°C whenever the remote is used, as per Bureau of Energy (Govt. of India) guidelines.
- Water drop, Dry: Removes moisture in humid weather. On Lloyd and Voltas the fan is low and the temperature is fixed at 24°C; you cannot change it.
- Fan or propeller, Fan: Only the indoor fan runs. The compressor is off (Voltas), so the room does not cool. The remote hides the set temperature (Lloyd).
- Sun, Heat: Warms the room. Only on heat-cool models. Lloyd says the fan may not start at once, so cold air does not blow at you.
- A, Auto or Ai: The AC picks fan and compressor speed itself. On Lloyd it runs at 24°C with auto fan, and you cannot change either.
From: Lloyd split AC manual; Voltas Vectra Elegant manual; Carrier Xcel Indus manual
Other common symbols on an AC remote
- Fan with bars: Fan speed. More bars = faster. Voltas cycles Low, Medium, High, Auto; Lloyd adds Silent and Turbo. Auto fan works only in Cool mode on Voltas.
- Louver with arrows (up-down or left-right): Swing. V-swing moves the air up and down, H-swing left and right (H-swing on some models only). Lloyd has 5 up-down and 3 left-right positions. On Carrier, each press moves the louver 6°; hold 3 seconds for continuous swing.
- Moon, Sleep: Night mode that raises the set temperature slowly. Voltas: +1°C in the first hour, +2°C total after 2 hours, Cool mode only. Carrier (Cool): +1°C after 1 hour and another +1°C after another hour. Lloyd: the indoor display dims and sleep ends after 8 hours.
- Clock with ON or OFF: On timer or Off timer. On Lloyd, one press of TIMER sets the Off timer and a 2-second hold sets the On timer.
- Turbo: Fast cooling at high fan. On Lloyd, Turbo stops by itself after 60 minutes unless the set temperature is 16°C.
- Leaf, Eco or Saver: Energy saving. Lloyd Smart Eco sets 24°C and auto fan. Voltas Saver sets 24°C and medium fan.
- Bulb, Lamp or Display: Turns the indoor unit display light off or on. On Voltas, pressing temperature up or down lights the display for 5 seconds.
- Padlock: Child lock: the remote stops sending signals. Lloyd: hold Minus and Fan together 5 seconds (same again to unlock). Voltas: press + and - together (again to unlock).
- Battery: Remote battery level. Lloyd shows a blinking battery or Lb when the batteries are low.
- Signal waves from a small tower: IR transmit. It shows each time the remote sends a signal.
- Wi-Fi arcs: Wi-Fi models only. On Lloyd the Wi-Fi icon blinks on the indoor unit while pairing and stays on once connected.
- Temp/Feeling key (Voltas): Shows the room temperature. Voltas shows it on the indoor display for 5 seconds.
From: Lloyd split AC manual; Voltas Vectra Elegant manual; Carrier Xcel Indus manual
Lloyd remote: 6-in-1, Constant, My Mode, DG and other icons
Lloyd's new remote (Havells, 2025 manual) has the most icons. Lloyd marks many as optional, on selected models only.
- 6-in-1 with C1 to C5 or CA: Capacity level. C1 = 40%, C2 = 60%, C3 = 80%, C4 = 100%, C5 = 110%. CA or blank is the default. In C1 to C3 the AC runs below its rated capacity, and the fan speeds you can pick are limited. Not in Dry or Fan mode.
- Constant: Constant cooling in Cool, Dry or Heat mode. Lloyd says it works best at standard voltage and temperature.
- Person icon, My Mode (or SE): Your saved favourite: mode, fan speed, temperature and swing. Hold MY MODE 5 seconds to set it; hold 2 seconds to switch it on or off. Removing the batteries erases it.
- DG: For running on a diesel generator. The indoor unit shows dg. Switching the AC off and on at the power switch turns DG mode off.
- Ice Clean: Self-clean: the coil frosts, then the melt water washes dust away. The indoor unit blinks Ic for 20 to 30 minutes, then the AC goes to standby. Lloyd suggests it every 2 to 4 weeks. Some noise is normal.
- Unit 1 (1 next to the moon): Unit 1 mode (the manual does not explain what it changes). The indoor unit shows 1u. Pressing Plus, Minus, Fan speed, Turbo and some other keys ends it.
- Puro Air: Air purifying only, for winter. The outdoor unit does not run; the indoor unit shows Pu.
- Drop (separate from the Dry icon), Humidity: Controls humidity and temperature together. Fan is automatic, temperature starts at 24°C and can be set from 22 to 26°C.
- Silent: Lowest indoor fan speed for less noise. Changing the fan speed ends it.
- Microphone, crossed or not: Voice assistant mic muted or on (Hello Lloyd models).
- Invalid: Lloyd's LCD chart names this icon Invalid command but does not explain it. The manual's tables list keys that cannot be used in some modes, for example Sleep in Dry, Fan or Ai/Auto.
- Two partition lines on the remote screen: The remote is in ON state. With the lines gone, the AC is off or standby; you can still set the timer, display and Wi-Fi.
From: Lloyd split AC manual
Letters on the indoor unit display that are not errors
- SL, Lo, hF, HI, tU (Lloyd): Fan speed: Silent, Low, Medium, High, Turbo.
- hi (Lloyd): The AC heard "Hello Lloyd" and is listening for a voice command.
- Go or ng (Lloyd): Result of Intelligent Diagnostic: Go = passed, ng = problem found.
- 60-second countdown after switching off (Lloyd): Blow, the anti-mould function: the fan dries the coil, then the louver closes. Voltas (Anti Fungi) and Carrier (Anti-mildew) have a similar after-run that keeps the fan going for a while; on Carrier, press Power two more times to stop it at once.
- CL (Lloyd, Carrier): Clean the filter. Carrier shows it after 240 hours of use; reset with the LED button 4 times on the remote, or the manual control button 3 times. Lloyd: hold Turbo 5 seconds.
- nF (Carrier): Replace the filter, after 2,880 hours of use. Reset it the same way as CL.
- KW (Carrier): Power use in kilowatts, on models with the KW display. Carrier says it can differ slightly from your meter.
dg, Ic, Pu and 1u above are also not errors (SE shows on the Lloyd remote screen, for My Mode). Two letters that are warnings: do on Lloyd (door open: the room keeps getting warmer) and EC on Carrier and Voltas (refrigerant leak). Our advice for EC: switch off and call service; do not open the unit.
From: Lloyd split AC manual; Voltas Vectra Elegant manual; Carrier Xcel Indus manual
Indoor unit lamps (Voltas and Carrier)
- Voltas Power lamp: Lights when the AC is in standby.
- Voltas Cool/Heat lamp: White in Cool mode, red in Heat mode (on models with this lamp).
- Voltas Dry, Timer and Sleep lamps: Dry mode on, a timer is set, sleep is on.
- Carrier RUN lamp: The AC is running.
- Carrier TIMER lamp: A timer is set.
- Carrier FRESH lamp: Clean Air feature is on (optional).
- Carrier DEFROST lamp: Heat-cool models: the AC is defrosting, or warm air control is on in Heat mode.
- Carrier RUN and TIMER flashing together: Filter reminder (with CL or nF). If instead TIMER goes off and RUN flashes 7 times with EC, the AC has found a refrigerant leak.
From: Voltas Vectra Elegant manual; Carrier Xcel Indus manual
Panasonic remote and indoor lamps (CS-XS UKY series)
- AUTO mode: The unit picks a standard 25°C, with fan speed and swing on Auto. You can still change the temperature.
- DRY: Low fan for gentle cooling that removes moisture.
- FAN: Fan only. The compressor does not run.
- SLEEP: Raises the set temperature by 1°C after every 3 hours and switches the unit off after 8 hours. Press again to cancel.
- POWERFUL/QUIET: One button for both. POWERFUL reaches the set temperature quickly and stops by itself after 1 hour. QUIET lowers airflow noise.
- nanoe-G: The air purifier. It starts with the unit and can also run with the AC off, as a fan with auto speed and swing.
- FAN SPEED and AIR SWING: Each press of FAN SPEED changes the speed; on AUTO the indoor fan adjusts itself to the mode. With AUTO swing in COOL or DRY, the flaps swing up-down and left-right by themselves. Panasonic says not to move the flap by hand.
- TIMER ON / OFF, SET, CANCEL: Pick ON or OFF, set the time, press SET. Timers repeat daily. With an ON timer the unit may start up to 15 minutes early to reach the temperature in time.
- RESET (small button at the bottom): Restores the remote to its default settings. Another small button there, held about 10 seconds, switches the temperature between °C and °F.
- Indoor lamps: POWER (yellow green), TIMER (orange), nanoe-G PURIFIER (blue), SLEEP/POWERFUL (orange or yellow green).
- TIMER lamp blinking and the unit stopped: An error. Panasonic's manual shows how to read the code with the CHECK button on the remote; models with a temperature display show the code by themselves.
Samsung remote and indoor display (AR**AY models)
- Mode button: Press Power, then Mode to pick Auto, Cool, Dry or Fan. The remote screen shows the word.
- Fast: In Cool mode, press Fast. The remote shows Fast.
- 5 Step Cooling: In Cool mode, press the 5 Step Cooling button. The remote shows 5step, and the indoor display has a 5 Step Cooling indicator.
- Options button + < > + SET: Many functions sit inside Options: press Options, move with < >, and press SET. That is how you pick Quiet (in Cool mode), Usage (electricity use, while running), Beep, Display (display lighting), Clean (to switch Auto clean off) and Filter Reset.
- Usage: Electricity consumption check. Samsung notes that on **12/18/24**4**** and **18**3**** models, Usage appears on the remote display but is not available.
- Timer and good'sleep: Timer sets on or off duration. good'sleep is chosen inside Timer in Cool mode, then you set the duration.
- Indoor display CF: Filter-cleaning reminder. Clean the filter, then reset it with Options > Filter Reset > SET.
- Indoor display numbers and kWh: A temperature, or (on AR18**5**** models) electricity consumption in kWh.
- Hold Options 3 seconds: Starts Auto clean, which Samsung suggests if the indoor unit smells. Holding Options for 3 seconds again cancels it while it runs.
Daikin remote buttons (inverter split, 3P719813 manual)
- ON/OFF: Press once to start, once again to stop.
- MODE: Selects DRY, COOL or FAN.
- FAN: Each press changes the airflow: AUTO, indoor unit quiet, then airflow rate 1 to 5 (low to high). In quiet the airflow is weak and the indoor unit is quieter. In DRY the airflow cannot be changed.
- POWER CHILL: Runs at maximum capacity to cool quickly, then returns to the previous settings after 20 minutes. Press again to cancel.
- ECONO: Limits maximum power use, useful so the breaker does not trip when other appliances share the circuit. Works in COOL and DRY, only while running; may not cool enough. POWER CHILL and ECONO cannot run together: the last button pressed wins.
- COANDA / STREAMER: A short press turns COANDA on or off: the flaps move up so air does not blow directly on people. A long press (5 seconds or more) turns STREAMER on or off (selected models), which works with the accessory filter to reduce odours and viruses.
- GOOD SLEEP / DISPLAY: During COOL, a press sets the GOOD SLEEP OFF timer (temperature shift, default 2, and stop time, default 2 hours). Holding it for 2 seconds or more cycles the indoor display through inverter output, indoor temperature and set temperature. F.L. means rated power use is exceeded; -- may show for a while after switch-on.
- ON TIMER / OFF TIMER / TIMER CANCEL: Each press changes the time by 1 hour (ON TIMER 1 to 12 hours, OFF TIMER 1 to 9 hours); TIMER CANCEL clears it. The TIMER lamp lights orange.
- DEW CLEAN: Hold for more than 2 seconds with the AC on; the green and orange lamps on the indoor unit blink together while it runs (not if the lamps were set to OFF with the brightness setting). See the AC self clean page.
- Child lock (ECONO + POWER CHILL, 5 s): Locks all buttons; a key symbol shows on the remote LCD and blinks if you press a button. Press both together for about 5 seconds again to unlock.
- Smell Proof: Before starting, set FAN to Auto, choose DRY or COOL, then press ON/OFF. Air starts about 1 minute later (at once with POWER CHILL). It prevents odour inside the indoor unit; Daikin says it prevents some odours, but not all.
Lost remote? Use the button on the indoor unit
- Lloyd: The emergency or AUX button starts the AC in Ai/Auto at 24°C, auto fan and auto swing.
- Voltas: The emergency key on the indoor unit runs the AC in Auto mode. Its place differs by model.
- Carrier: Open the front panel and press MANUAL CONTROL once for forced Auto, twice for forced Cool, three times for off. Carrier says it is for emergencies only.
- Panasonic: Raise the front panel and press Auto OFF/ON once for AUTO; hold it until 1 beep for COOL.
- Daikin: Press the indoor unit ON/OFF switch once to start and once again to stop. It runs in COOL at 22°C with AUTO airflow.
From: Lloyd split AC manual; Voltas Vectra Elegant manual; Carrier Xcel Indus manual; Panasonic CS-XS UKY manual; Daikin inverter split AC manual
Display letters in our code lists
- Lloyd dg (Inverter split): DG mode is on (switched on with the DG key, for running on a diesel generator). "dg" shows continuously; switching the AC off and on at the power switch ends it (newer manual p.42)
- Lloyd Ic (Inverter split): Ice Clean is running: "Ic" blinks during the 20-30 minute self-clean, then the AC goes to standby (newer manual p.43)
- Lloyd do (Inverter split): Door open alert: room temperature keeps rising, so the AC warns of low cooling, as from an open door. Shows "do" for a few seconds with a beep (selected models, newer manual p.37)
- Lloyd LO / Lb (Inverter split): Remote control battery low: the remote handset shows Lb or Lo (newer manual)
- Lloyd CL (Inverter split): Filter cleaning reminder (selected models)
- Carrier CL (Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)): Filter cleaning reminder after 240 hours of use (not a fault)
- Carrier nF (Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)): Filter replacement reminder after 2,880 hours of use (not a fault)
- Carrier EC (Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)): Refrigerant leakage detected (optional feature)
- Voltas EC (Split AC, "conventional series" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)): Gas leak detection
हिंदी में
AC रिमोट के निशान: बर्फ = कूल, पानी की बूंद = ड्राई (नमी हटाता है), पंखा = सिर्फ हवा (ठंडा नहीं करता), सूरज = हीट (सिर्फ हीट-कूल मॉडल), A या Ai = ऑटो। चांद = स्लीप, घड़ी = टाइमर, ताला = चाइल्ड लॉक, बैटरी = रिमोट की बैटरी। इंडोर यूनिट पर dg, Ic, Pu, 1u जैसे अक्षर खराबी नहीं हैं, ये चालू फीचर बताते हैं।
- ठंडक नहीं आ रही तो देखें बर्फ (Cool) वाला निशान चुना है, पंखे वाला नहीं।
- Turbo जल्दी ठंडा करता है; Eco या Saver 24°C पर बिजली बचाता है।
- Lloyd 6-in-1 में C1 से C5 = 40% से 110% क्षमता। C1-C3 में ठंडक कम होगी।
- रिमोट लॉक हो गया तो Lloyd में Minus और Fan 5 सेकंड, Voltas में + और - साथ दबाएं।
- CL दिखे तो फ़िल्टर साफ करें। EC दिखे तो AC बंद करके सर्विस बुलाएं।
- Samsung: Fast और 5 Step Cooling सिर्फ Cool मोड में। Quiet, Beep, Display, Filter Reset जैसे काम Options दबाकर < > से चुनें और SET दबाएँ। इनडोर पर CF = फ़िल्टर साफ़ करने की याद; रीसेट AC चलते समय करें।
Questions people ask
What does the snowflake symbol mean on an AC remote?
It is Cool mode, the normal cooling setting. The drop is Dry mode, the fan is Fan-only mode and the sun is Heat mode (heat-cool models only).
Which AC mode is best in humid weather?
Dry mode (the water drop). It removes moisture. On Lloyd and Voltas the fan runs low and the temperature stays at 24°C. Lloyd also has a Humidity mode that controls humidity and temperature together.
Why does my AC remote show Invalid?
Lloyd's new remote has an Invalid command icon. The manual lists keys that cannot be used in some modes, for example Sleep in Dry, Fan or Ai/Auto mode, or Turbo in Dry and Fan. Switch to a mode that allows the function.
What is 6-in-1 on a Lloyd AC remote?
It sets capacity: C1 40%, C2 60%, C3 80%, C4 100%, C5 110%, or CA/blank for normal. It works in Cool and Ai/Auto (the table on p.33 also lists Heat), not in Dry or Fan.
How do I unlock an AC remote?
Lloyd: hold Minus and Fan together for 5 seconds. Voltas: press + and - together. The same combination locks it.
Why does the AC fan keep running after I switch it off?
It is drying the coil to stop mould: Lloyd calls it Blow (60-second countdown), Voltas Anti Fungi, Carrier Anti-mildew. It stops by itself.
How do I reset an AC remote?
Lloyd: take out the batteries, press any key, and put them back; all icons light for 2 seconds and saved settings are erased. Voltas says you can take out the batteries to clear an abnormal display.
What does POWERFUL/QUIET mean on a Panasonic AC remote?
It is one button for two modes. POWERFUL reaches the set temperature quickly and stops automatically after 1 hour. QUIET reduces airflow noise.
What does CF mean on a Samsung AC?
On Samsung AR**AY split ACs, CF on the indoor display is the filter-cleaning reminder. Clean the filter, then, while the AC is running, press Options, select Filter Reset with < > and press SET.
Sources
- Lloyd split AC user manual, new remote (Havells, 2025): remote buttons PDF p.14, remote LCD chart p.15, functions p.16-48 (modes p.18-21, fan p.21-22, swing p.23-25, sleep p.25, Turbo p.26-27, Eco and My Mode p.27-29, timer p.29-31, display and buzzer p.31-32, 6-in-1 p.32-33, lock and reset p.33-34, Constant p.34-35, Blow and Humidity p.35-36, Silent p.37, Wi-Fi and diagnostic p.37-39, emergency button p.39, filter reminder p.40, door open and I Feel p.41-42, Puro Air p.44, DG and Ice Clean p.46-47, Unit 1 and mic p.47-48, IDU fan letters p.50, display codes incl. CL p.51-52)
- Voltas SAC 123 Vectra Elegant split AC user manual: emergency key PDF p.8, indoor display lamps p.9-11, features, anti fungi and remote batteries p.12, remote keys p.13, operating modes p.14, error codes (EC) p.15
- Carrier Xcel Indus split AC user manual (2024): display lamps p.6, default 24°C p.7, anti-mildew, refrigerant leak and filter reminders p.8, airflow p.9, sleep p.10, manual operation p.11
- Panasonic CS-XS12UKY / XS18UKY / XS24UKY series operating instructions (Panasonic India): How to use p.6-7, troubleshooting and error code check p.9
- Samsung split AC user manual DB68-09629F-01 (AR**AY*Y*** / AR**AY*Z*** models, 2021): indoor display p.10, Functions and Buttons p.11, Auto clean and filter reset p.12-13 (Samsung India support page for AR12AY4YATZNNA)
- Daikin India inverter split AC operation and installation manual 3P719813-1Z: indoor unit ON/OFF switch p.2, remote controller buttons and notes p.3, Streamer p.5, airflow rate, Smell Proof and Child Lock p.6, Coanda, Power Chill and Econo p.8, timer and Good Sleep p.9, inverter output and temperature display p.10, Dew Clean p.11 (printed page numbers)
Last checked: