AC modes explained: what Eco, Turbo, Dry, Fan, Auto and Sleep do
Quick answer
Daikin ECONO and LG AC + 4 limit how much power the AC draws, so it may cool less: Daikin caps the maximum power so the breaker does not trip, and LG cuts power input by 20%, 40% or 60%. Lloyd's Smart Eco instead sets 24 °C and Auto fan. Turbo cools faster for a while: Daikin POWER CHILL runs at maximum capacity and stops after 20 minutes, Lloyd TURBO stops after 60 minutes (unless set to 16 °C), and Panasonic POWERFUL stops after 1 hour. Dry removes moisture: Lloyd, Voltas and Panasonic run it at low fan speed, LG and Daikin set temperature and fan themselves, and Lloyd and Voltas fix the temperature at 24 °C. Fan only moves air without cooling. Sleep slowly raises the set temperature during the night: LG, Voltas and Carrier by 2 °C in total, while on Daikin you choose 1 to 5 °C (default 2).
Jump to: EcoTurboDryFanAutoSleep
Eco mode: lower power or a fixed setting
- Daikin, ECONO: ECONO limits the maximum power consumption. Daikin says it is useful to stop the circuit breaker tripping when the AC runs alongside other appliances on the same circuit. It works only in COOL and DRY, only while the unit is running, and because it runs at lower power it may not give enough cooling. ECONO and POWER CHILL cannot run together: the last button pressed wins.
- LG, AC + 4 (6-in-1/AC + 4 button): Step 1 is AI Convertible mode. Steps 2, 3 and 4 cut the power input by 20%, 40% and 60% of the rated input (step 4 on some models); some indoor units show L or LL. It works only in Cooling mode, and LG says capacity may decrease.
- Lloyd, SMART ECO (ECO button): In COOL or HEAT, Smart Eco sets the AC to 24 °C with fan speed Auto, and an Eco icon shows on the set temperature screen. It cannot be selected in Auto, Dry, Fan, Constant or 6-in-1. Pressing Sleep or Turbo turns Eco off.
From: Daikin 3P719813-1Z manual; LG AC manual MFL72020502; Lloyd AC manual (new remote)
Turbo mode: faster cooling
- Daikin, POWER CHILL: Runs the AC at maximum capacity to cool quickly in any mode, then stops after 20 minutes and goes back to the settings you had before. In DRY it lowers the set temperature by 2.5 °C and slightly raises the airflow; in FAN it fixes the airflow at maximum.
- Lloyd, TURBO: Powerful cooling or heating. In COOL or HEAT at 16 °C it keeps running; at 17 °C to 30 °C it switches off by itself after 60 minutes. It cannot be selected in Auto, Ai, Dry, Fan or Humidity mode, and pressing Sleep or Eco ends it.
- Panasonic, POWERFUL: Reaches the set temperature quickly and stops automatically after 1 hour. The same button switches to QUIET, which lowers airflow noise.
- LG, VIRAAT (6-in-1/VIRAAT button): Changes the room temperature quickly: strong air blows out and auto swing switches on. On cooling-only models it works with Cooling, Dehumidification, Fan and Air Purification.
- Voltas, TURBO: Pressing the Turbo key sets the fan to high speed.
From: Daikin 3P719813-1Z manual; Lloyd AC manual (new remote); Panasonic CS-XS UKY manual; LG AC manual MFL72020502; Voltas Vectra Elegant manual
Dry mode: removes moisture
- LG, Dehumidification (Monsoon Operation): Reduces moisture in humid weather or the rainy season to stop mildew. The AC sets the temperature and fan speed itself, so you cannot adjust the room temperature, and the compressor and indoor fan may stop to avoid over-cooling.
- Daikin, DRY: Removes humidity while keeping the room temperature as steady as possible. Temperature and airflow are controlled automatically, so you cannot change them. If you switch the AC off in DRY, it starts in COOL next time from the remote.
- Lloyd, DRY: Works like a dehumidifier. On some models the set temperature is fixed at 24 °C and the fan speed at low.
- Voltas, Dry: Fan speed is low and the set temperature of 24 °C cannot be changed. The compressor cycles the same way as in cool mode.
- Panasonic, DRY: Runs at low fan speed for gentle cooling.
From: LG AC manual MFL72020502; Daikin 3P719813-1Z manual; Lloyd AC manual (new remote); Voltas Vectra Elegant manual; Panasonic CS-XS UKY manual
Fan mode: air moves, no cooling
- LG: Circulates the room air without changing the room temperature.
- Panasonic: The compressor does not run; only the indoor fan runs at the speed and airflow direction you set.
- Lloyd: Circulates and refreshes stale air. You can pick Silent, Low, Medium or High fan; no set temperature shows on the remote.
- Daikin: In FAN (and DRY) the temperature setting cannot be changed.
From: LG AC manual MFL72020502; Panasonic CS-XS UKY manual; Lloyd AC manual (new remote); Daikin 3P719813-1Z manual
Auto and AI modes
- Lloyd, Ai / AUTO (some models): Cools or heats automatically, controlling fan and compressor speed as the room nears the set temperature. Set temperature is fixed at 24 °C and fan at Auto.
- Panasonic, AUTO: The unit picks a standard temperature of 25 °C with fan and swing on auto, and you can change the temperature.
- LG, AI Convertible: The set temperature, fan speed and airflow direction change automatically. From Cooling mode, LG says the AC analyses the surroundings to reach the set temperature quickly.
From: Lloyd AC manual (new remote); Panasonic CS-XS UKY manual; LG AC manual MFL72020502
Sleep mode: temperature creeps up at night
- LG: In Cooling and Dehumidification, the set temperature rises 1 °C after 30 minutes and another 1 °C after the next 30 minutes, up to 2 °C. The AC turns off after the time you set (up to 7 hours) and fan speed is automatic.
- Daikin, GOOD SLEEP OFF TIMER: Used in COOL. The set temperature rises 0.5 °C every 30 minutes until it reaches the shift value (default 2), and the AC turns off at the time you set (1 to 9 hours).
- Lloyd, SMART SLEEP: The indoor display dims and sleep ends after 8 hours. On inverter models the set temperature rises in the background and the new value shows after 8 hours.
- Panasonic: Raises the set temperature by 1 °C after every 3 hours and turns the unit off after 8 hours.
- Voltas: Works only in cool mode. The set temperature goes up 1 °C in the first hour, 2 °C in total after 2 hours.
- Carrier: In COOL the temperature goes up 1 °C after 1 hour and another 1 °C after another hour. Not available in FAN or DRY. Depending on the unit, sleep stops after 8 hours or the AC turns off after 7 hours.
From: LG AC manual MFL72020502; Daikin 3P719813-1Z manual; Lloyd AC manual (new remote); Panasonic CS-XS UKY manual; Voltas Vectra Elegant manual; Carrier Xcel Indus manual
हिंदी में
Daikin ECONO और LG AC + 4 में AC कम बिजली लेता है, इसलिए ठंडक कम हो सकती है। Turbo जल्दी ठंडा करता है; कुछ मॉडल में यह तय समय बाद अपने आप बंद होता है। Dry मोड नमी निकालता है, Fan मोड सिर्फ हवा चलाता है, ठंडा नहीं करता। Sleep मोड रात में सेट तापमान धीरे-धीरे बढ़ाता है।
- Daikin ECONO: ज़्यादा से ज़्यादा बिजली सीमित करता है, ताकि एक ही सर्किट पर दूसरे उपकरण चलने पर MCB न गिरे। सिर्फ COOL और DRY में।
- LG AC + 4: बिजली 20%, 40% या 60% कम करता है। सिर्फ Cooling मोड में, ठंडक कम हो सकती है।
- Lloyd Smart Eco: COOL/HEAT में 24 °C और फैन Auto कर देता है।
- Turbo: Daikin POWER CHILL 20 मिनट, Lloyd TURBO 60 मिनट (16 °C पर चलता रहता है), Panasonic POWERFUL 1 घंटे बाद बंद।
- Dry: Lloyd, Voltas, Panasonic में पंखा धीमा; Lloyd और Voltas में तापमान 24 °C तय; LG और Daikin तापमान और पंखा खुद सेट करते हैं।
- Fan: कंप्रेसर नहीं चलता, सिर्फ हवा चलती है।
- Sleep: तापमान धीरे-धीरे बढ़ता है (LG, Voltas, Carrier में कुल 2 °C; Daikin में आप 1 से 5 °C चुन सकते हैं) और तय समय के बाद AC बंद हो सकता है।
Questions people ask
Does Eco mode save electricity on an AC?
On the models covered here it lowers power use: Daikin ECONO limits maximum power consumption and LG AC + 4 cuts power input by 20%, 40% or 60%. Both makers say cooling may be lower as a result.
Why is my AC not cooling well in Eco mode?
Daikin says ECONO runs at lower power and may not provide enough cooling, and LG says capacity may decrease with AC + 4. Switch Eco off when the room needs fast cooling.
How long does Turbo mode run?
Daikin POWER CHILL ends after 20 minutes, Lloyd TURBO after 60 minutes when set between 17 °C and 30 °C (at 16 °C it keeps running), and Panasonic POWERFUL after 1 hour.
Why can't I change the temperature in Dry mode?
LG and Daikin set the temperature automatically in Dry mode, and Lloyd and Voltas fix it at 24 °C with low fan.
Does Fan mode cool the room?
No. Panasonic says the compressor does not run in Fan mode, and LG says it circulates air without changing the room temperature.
What does Sleep mode do on an AC?
It raises the set temperature a little during the night: for example LG adds 1 °C after 30 minutes and another 1 °C after the next 30 minutes, and Voltas adds 1 °C in the first hour, 2 °C in total after 2 hours.
Sources
- LG India split air conditioner owner's manual MFL72020502 (Rev.01, 2023), PDF page numbers: remote buttons p.15, operating modes p.17-18, VIRAAT p.18-19, Sleep p.21-22, AC + 4 and AI Convertible p.23-24 (LG India support page, Manuals section)
- Daikin India inverter split AC operation and installation manual 3P719813-1Z: DRY, COOL, FAN operation printed p.5-6, POWER CHILL and ECONO p.8, GOOD SLEEP OFF TIMER p.9
- Lloyd split AC user manual, new remote (Havells, 2025): modes PDF p.18-20, Sleep p.25-26, Turbo p.26-27, Smart Eco p.27-28
- Panasonic CS-XS12UKY / XS18UKY / XS24UKY series operating instructions (Panasonic India): How to use (modes, Sleep, Powerful/Quiet) p.6
- Voltas SAC 123 Vectra Elegant split AC user manual: remote keys (Sleep, Turbo) PDF p.13, operating modes (Dry) p.14
- Carrier Xcel Indus split AC user manual (2024): Sleep operation p.10
Last checked: