हिंदी

Onida AC Error Codes: E1, E4, E6, FC, F1, P4 (Inverter and Fixed Speed)

By FaultDecode · Checked against Onida's official documents · Updated · How we check

43 Onida codes on this page.

Every row here comes from an Onida AC user manual on onida.com. Onida has two current manuals and they do not agree on every code. On the 2026 manual's fixed-speed table E1 is an indoor fan fault, but on the All Models manual's fixed-speed table E1 is a room sensor fault. Inverter models show the code on the indoor display, and Onida's 2026 manual also gives the number of times the outdoor unit LED flashes for each code. Find your model type (inverter or fixed speed) first, then read the matching rows.

Safety: Onida says: if the power cord is overheating or damaged, there is an abnormal sound, the air switch trips often, there is a burning smell or the indoor unit is leaking, turn off the AC, disconnect the power at once and contact the dealer or a qualified professional. For any code not in its tables, Onida says to contact qualified professionals.

How to see the code

  1. On a fixed-speed Onida AC, the temperature display on the indoor unit blinks to show the code.
  2. On an inverter Onida AC, the AC stops and the code shows on the indoor display. On selected models the outdoor unit LED also flashes a set number of times; the count is next to each code below.
  3. Check whether your AC is inverter or fixed speed (rating sticker or manual cover), then read the matching rows.

Only a blinking light? Use the Onida blink decoder: tap once per flash and see the code.

How to check the error code on other AC brands

Onida AC error code list

CodeModel typeMeaning
EE (outdoor 25 flashes) Inverter (2026 manual, selected models) Indoor unit EE fault
E1 (outdoor 26 flashes) Inverter (2026 manual, selected models) Indoor fan fault
E2 (outdoor 27 flashes) Inverter (2026 manual, selected models) Indoor fan zero-crossing detection fault
E3 (outdoor 28 flashes) Inverter (2026 manual, selected models) Indoor coil temperature sensor fault
E4 (outdoor 29 flashes) Inverter (2026 manual, selected models) Indoor ambient temperature sensor fault
E0 (outdoor 1 flash) Inverter (2026 manual, selected models) Outdoor unit EE fault
E6 (outdoor 2 flashes) Inverter (2026 manual, selected models) Indoor and outdoor unit communication fault
F1 (outdoor 4 flashes) Inverter (2026 manual, selected models) Compressor starting abnormal
F2 (outdoor 5 flashes) Inverter (2026 manual, selected models) Compressor drive fault
F3 (outdoor 6 flashes) Inverter (2026 manual, selected models) IPM module fault
F4 (outdoor 7 flashes) Inverter (2026 manual, selected models) Compressor shell top fault
F5 (outdoor 8 flashes) Inverter (2026 manual, selected models) Discharge temperature sensor fault
F6 (outdoor 9 flashes) Inverter (2026 manual, selected models) Suction temperature sensor fault
F7 (outdoor 10 flashes) Inverter (2026 manual, selected models) Outdoor coil temperature sensor fault
F8 (outdoor 11 flashes) Inverter (2026 manual, selected models) Outdoor ambient temperature sensor fault
F9 (outdoor 12 flashes) Inverter (2026 manual, selected models) Outdoor DC fan fault
P1 (outdoor 13 flashes) Inverter (2026 manual, selected models) Outdoor unit AC current protection
P2 (outdoor 14 flashes) Inverter (2026 manual, selected models) Compressor phase current protection
P3 (outdoor 15 flashes) Inverter (2026 manual, selected models) Outdoor unit AC voltage too high or too low (protection)
P4 (outdoor 16 flashes) Inverter (2026 manual, selected models) DC overvoltage or undervoltage protection
P5 (outdoor 17 flashes) Inverter (2026 manual, selected models) IPM overheat protection
P6 (outdoor 18 flashes) Inverter (2026 manual, selected models) Discharge temperature overheat protection
P7 (outdoor 19 flashes) Inverter (2026 manual, selected models) Indoor coil anti-freezing protection in cooling
P8 (outdoor 20 flashes) Inverter (2026 manual, selected models) Outdoor coil overheat protection in cooling
P9 (outdoor 21 flashes) Inverter (2026 manual, selected models) Indoor coil overheat protection in heating
PC (outdoor 22 flashes) Inverter (2026 manual, selected models) Outdoor temperature too low for cooling (protection)
PH (outdoor 23 flashes) Inverter (2026 manual, selected models) Outdoor temperature too high for heating (protection)
L1 (outdoor 31 flashes) Inverter (2026 manual, selected models) Drive bus voltage too high (protection)
L2 (outdoor 32 flashes) Inverter (2026 manual, selected models) Drive bus voltage too low (protection)
L3 (outdoor 33 flashes) Inverter (2026 manual, selected models) Drive phase current overload fault
L4 (outdoor 34 flashes) Inverter (2026 manual, selected models) Phase current sampling abnormal
FC (outdoor 35 flashes) Inverter (2026 manual, selected models) Filter clean reminder (not a fault). Onida: press SLEEP 4 times within 8 seconds to reset
EB Inverter (All Models manual) Outdoor communication fault
F2 Inverter (All Models manual) Compressor out-of-step fault
EE Fixed speed (2026 manual) Indoor unit EE fault
E1 Fixed speed (2026 manual) Indoor fan fault
E3 Fixed speed (2026 manual) Indoor coil temperature sensor fault
E4 Fixed speed (2026 manual) Indoor ambient temperature sensor fault
P7 Fixed speed (2026 manual) Indoor coil anti-freezing protection in cooling
E1 (alternates with set temperature every 4 seconds) Fixed speed (All Models manual) Room sensor short or open
E2 (alternates with set temperature every 4 seconds) Fixed speed (All Models manual) Coil sensor short or open
E5/H6 Fixed speed (All Models manual) Fan motor error
dF Fixed speed (All Models manual) Defrost error

No code, but a problem?

Good to know

हिंदी में

Onida AC में कोड इंडोर यूनिट के डिस्प्ले पर दिखता है। कुछ इन्वर्टर मॉडल में आउटडोर यूनिट की LED भी तय बार झपकती है। Onida के दो मैनुअल में कुछ कोड का मतलब अलग है, इसलिए पहले देखें कि AC इन्वर्टर है या फिक्स्ड स्पीड।

  1. AC के स्टिकर या मैनुअल से देखें कि मॉडल इन्वर्टर है या फिक्स्ड स्पीड।
  2. डिस्प्ले का कोड नीचे की तालिका में अपने मॉडल वाली लाइन में देखें।
  3. FC आए तो फ़िल्टर साफ़ करें और SLEEP बटन 8 सेकंड में 4 बार दबाएं।
  4. जलने की गंध, तार गर्म होना, अजीब आवाज़, बार-बार MCB गिरना या पानी टपकना हो तो AC बंद करें, बिजली हटाएं और सर्विस बुलाएं।

Questions people ask

What is E1 error in an Onida AC?

It depends on the model. Onida's inverter table and the 2026 fixed-speed table say E1 is an indoor fan fault. The All Models manual's fixed-speed table says E1 means the room sensor is short or open, and the display alternates E1 with the set temperature every 4 seconds.

What does FC mean on an Onida AC?

FC stands for Filter Clean. It is a reminder, not a fault. Onida's 2026 manual says to reset it by pressing SLEEP 4 times within 8 seconds.

What is E6 in an Onida inverter AC?

Onida lists E6 as an indoor and outdoor unit communication fault. On selected inverter models the outdoor LED flashes 2 times. Onida gives no home fix for it, so call a qualified technician.

Why is my Onida AC outdoor light blinking?

On selected Onida inverter models the outdoor unit LED flashes a number of times to show a fault code. Count the flashes and match the count in the table below, or use the blink decoder.

Sources

Last checked:

↑