Onida AC Error Codes: E1, E4, E6, FC, F1, P4 (Inverter and Fixed Speed)
43 Onida codes on this page.
Every row here comes from an Onida AC user manual on onida.com. Onida has two current manuals and they do not agree on every code. On the 2026 manual's fixed-speed table E1 is an indoor fan fault, but on the All Models manual's fixed-speed table E1 is a room sensor fault. Inverter models show the code on the indoor display, and Onida's 2026 manual also gives the number of times the outdoor unit LED flashes for each code. Find your model type (inverter or fixed speed) first, then read the matching rows.
Safety: Onida says: if the power cord is overheating or damaged, there is an abnormal sound, the air switch trips often, there is a burning smell or the indoor unit is leaking, turn off the AC, disconnect the power at once and contact the dealer or a qualified professional. For any code not in its tables, Onida says to contact qualified professionals.
How to see the code
- On a fixed-speed Onida AC, the temperature display on the indoor unit blinks to show the code.
- On an inverter Onida AC, the AC stops and the code shows on the indoor display. On selected models the outdoor unit LED also flashes a set number of times; the count is next to each code below.
- Check whether your AC is inverter or fixed speed (rating sticker or manual cover), then read the matching rows.
Only a blinking light? Use the Onida blink decoder: tap once per flash and see the code.
Onida AC error code list
| Code | Model type | Meaning |
|---|---|---|
| EE (outdoor 25 flashes) | Inverter (2026 manual, selected models) | Indoor unit EE fault |
| E1 (outdoor 26 flashes) | Inverter (2026 manual, selected models) | Indoor fan fault |
| E2 (outdoor 27 flashes) | Inverter (2026 manual, selected models) | Indoor fan zero-crossing detection fault |
| E3 (outdoor 28 flashes) | Inverter (2026 manual, selected models) | Indoor coil temperature sensor fault |
| E4 (outdoor 29 flashes) | Inverter (2026 manual, selected models) | Indoor ambient temperature sensor fault |
| E0 (outdoor 1 flash) | Inverter (2026 manual, selected models) | Outdoor unit EE fault |
| E6 (outdoor 2 flashes) | Inverter (2026 manual, selected models) | Indoor and outdoor unit communication fault |
| F1 (outdoor 4 flashes) | Inverter (2026 manual, selected models) | Compressor starting abnormal |
| F2 (outdoor 5 flashes) | Inverter (2026 manual, selected models) | Compressor drive fault |
| F3 (outdoor 6 flashes) | Inverter (2026 manual, selected models) | IPM module fault |
| F4 (outdoor 7 flashes) | Inverter (2026 manual, selected models) | Compressor shell top fault |
| F5 (outdoor 8 flashes) | Inverter (2026 manual, selected models) | Discharge temperature sensor fault |
| F6 (outdoor 9 flashes) | Inverter (2026 manual, selected models) | Suction temperature sensor fault |
| F7 (outdoor 10 flashes) | Inverter (2026 manual, selected models) | Outdoor coil temperature sensor fault |
| F8 (outdoor 11 flashes) | Inverter (2026 manual, selected models) | Outdoor ambient temperature sensor fault |
| F9 (outdoor 12 flashes) | Inverter (2026 manual, selected models) | Outdoor DC fan fault |
| P1 (outdoor 13 flashes) | Inverter (2026 manual, selected models) | Outdoor unit AC current protection |
| P2 (outdoor 14 flashes) | Inverter (2026 manual, selected models) | Compressor phase current protection |
| P3 (outdoor 15 flashes) | Inverter (2026 manual, selected models) | Outdoor unit AC voltage too high or too low (protection) |
| P4 (outdoor 16 flashes) | Inverter (2026 manual, selected models) | DC overvoltage or undervoltage protection |
| P5 (outdoor 17 flashes) | Inverter (2026 manual, selected models) | IPM overheat protection |
| P6 (outdoor 18 flashes) | Inverter (2026 manual, selected models) | Discharge temperature overheat protection |
| P7 (outdoor 19 flashes) | Inverter (2026 manual, selected models) | Indoor coil anti-freezing protection in cooling |
| P8 (outdoor 20 flashes) | Inverter (2026 manual, selected models) | Outdoor coil overheat protection in cooling |
| P9 (outdoor 21 flashes) | Inverter (2026 manual, selected models) | Indoor coil overheat protection in heating |
| PC (outdoor 22 flashes) | Inverter (2026 manual, selected models) | Outdoor temperature too low for cooling (protection) |
| PH (outdoor 23 flashes) | Inverter (2026 manual, selected models) | Outdoor temperature too high for heating (protection) |
| L1 (outdoor 31 flashes) | Inverter (2026 manual, selected models) | Drive bus voltage too high (protection) |
| L2 (outdoor 32 flashes) | Inverter (2026 manual, selected models) | Drive bus voltage too low (protection) |
| L3 (outdoor 33 flashes) | Inverter (2026 manual, selected models) | Drive phase current overload fault |
| L4 (outdoor 34 flashes) | Inverter (2026 manual, selected models) | Phase current sampling abnormal |
| FC (outdoor 35 flashes) | Inverter (2026 manual, selected models) | Filter clean reminder (not a fault). Onida: press SLEEP 4 times within 8 seconds to reset |
| EB | Inverter (All Models manual) | Outdoor communication fault |
| F2 | Inverter (All Models manual) | Compressor out-of-step fault |
| EE | Fixed speed (2026 manual) | Indoor unit EE fault |
| E1 | Fixed speed (2026 manual) | Indoor fan fault |
| E3 | Fixed speed (2026 manual) | Indoor coil temperature sensor fault |
| E4 | Fixed speed (2026 manual) | Indoor ambient temperature sensor fault |
| P7 | Fixed speed (2026 manual) | Indoor coil anti-freezing protection in cooling |
| E1 (alternates with set temperature every 4 seconds) | Fixed speed (All Models manual) | Room sensor short or open |
| E2 (alternates with set temperature every 4 seconds) | Fixed speed (All Models manual) | Coil sensor short or open |
| E5/H6 | Fixed speed (All Models manual) | Fan motor error |
| dF | Fixed speed (All Models manual) | Defrost error |
No code, but a problem?
- AC not cooling: what to check before calling service
- AC filter cleaning: how often and how to do it
- Water dripping from the AC indoor unit: causes and what to do
- AC remote symbols meaning
- AC modes explained: what Eco, Turbo, Dry, Fan, Auto and Sleep do
- AC making noise: normal sounds and warning sounds
- AC remote not working: what to check
- AC smell: what the manuals say about bad odour, burning smell and smoke
- How to reset an AC
- AC not turning on, or turning off by itself: what to check
- AC self clean and auto clean: what they do
Good to know
- Onida's inverter table says it is for selected models only.
- The All Models manual's inverter table has EB (outdoor communication fault) and calls F2 a compressor out-of-step fault; the 2026 manual calls F2 a compressor drive fault and has no EB.
- FC is a filter clean reminder, not a fault. Onida's 2026 manual says to press SLEEP 4 times within 8 seconds to reset it.
- The 2026 manual also describes a lab test mode in which the whole display blinks. Onida says it is for lab testing only, not for customer use, and that setting it may make the unit malfunction.
हिंदी में
Onida AC में कोड इंडोर यूनिट के डिस्प्ले पर दिखता है। कुछ इन्वर्टर मॉडल में आउटडोर यूनिट की LED भी तय बार झपकती है। Onida के दो मैनुअल में कुछ कोड का मतलब अलग है, इसलिए पहले देखें कि AC इन्वर्टर है या फिक्स्ड स्पीड।
- AC के स्टिकर या मैनुअल से देखें कि मॉडल इन्वर्टर है या फिक्स्ड स्पीड।
- डिस्प्ले का कोड नीचे की तालिका में अपने मॉडल वाली लाइन में देखें।
- FC आए तो फ़िल्टर साफ़ करें और SLEEP बटन 8 सेकंड में 4 बार दबाएं।
- जलने की गंध, तार गर्म होना, अजीब आवाज़, बार-बार MCB गिरना या पानी टपकना हो तो AC बंद करें, बिजली हटाएं और सर्विस बुलाएं।
Questions people ask
What is E1 error in an Onida AC?
It depends on the model. Onida's inverter table and the 2026 fixed-speed table say E1 is an indoor fan fault. The All Models manual's fixed-speed table says E1 means the room sensor is short or open, and the display alternates E1 with the set temperature every 4 seconds.
What does FC mean on an Onida AC?
FC stands for Filter Clean. It is a reminder, not a fault. Onida's 2026 manual says to reset it by pressing SLEEP 4 times within 8 seconds.
What is E6 in an Onida inverter AC?
Onida lists E6 as an indoor and outdoor unit communication fault. On selected inverter models the outdoor LED flashes 2 times. Onida gives no home fix for it, so call a qualified technician.
Why is my Onida AC outdoor light blinking?
On selected Onida inverter models the outdoor unit LED flashes a number of times to show a fault code. Count the flashes and match the count in the table below, or use the blink decoder.
Sources
- Onida AC user manual 2026 (R4-07102026): fixed-speed error codes p.29, inverter error codes with outdoor LED flashes p.30, warning list p.29
- Onida AC user manual, All Models (inverter and fixed speed): fixed-speed error codes p.30, inverter error codes p.31
Last checked: