हिंदी

Onida AC blinking light codes

By FaultDecode · From Onida's official manual · Updated · How we check

No code on the display, only a blinking light? Some Onida models also show the fault as a number of flashes. Count them and pick the light below. Every row comes from the Onida AC error code list. Other brand? See AC light blinking on every brand.

Safety: Onida says: if the power cord is overheating or damaged, there is an abnormal sound, the air switch trips often, there is a burning smell or the indoor unit is leaking, turn off the AC, disconnect the power at once and contact the dealer or a qualified professional. For any code not in its tables, Onida says to contact qualified professionals.

How to count the flashes

  1. On a fixed-speed Onida AC, the temperature display on the indoor unit blinks to show the code.
  2. On an inverter Onida AC, the AC stops and the code shows on the indoor display. On selected models the outdoor unit LED also flashes a set number of times; the count is next to each code below.

Outdoor light flashes

FlashesCodeModel typeMeaning
1 E0 Inverter (2026 manual, selected models) Outdoor unit EE fault
2 E6 Inverter (2026 manual, selected models) Indoor and outdoor unit communication fault
4 F1 Inverter (2026 manual, selected models) Compressor starting abnormal
5 F2 Inverter (2026 manual, selected models) Compressor drive fault
6 F3 Inverter (2026 manual, selected models) IPM module fault
7 F4 Inverter (2026 manual, selected models) Compressor shell top fault
8 F5 Inverter (2026 manual, selected models) Discharge temperature sensor fault
9 F6 Inverter (2026 manual, selected models) Suction temperature sensor fault
10 F7 Inverter (2026 manual, selected models) Outdoor coil temperature sensor fault
11 F8 Inverter (2026 manual, selected models) Outdoor ambient temperature sensor fault
12 F9 Inverter (2026 manual, selected models) Outdoor DC fan fault
13 P1 Inverter (2026 manual, selected models) Outdoor unit AC current protection
14 P2 Inverter (2026 manual, selected models) Compressor phase current protection
15 P3 Inverter (2026 manual, selected models) Outdoor unit AC voltage too high or too low (protection)
16 P4 Inverter (2026 manual, selected models) DC overvoltage or undervoltage protection
17 P5 Inverter (2026 manual, selected models) IPM overheat protection
18 P6 Inverter (2026 manual, selected models) Discharge temperature overheat protection
19 P7 Inverter (2026 manual, selected models) Indoor coil anti-freezing protection in cooling
20 P8 Inverter (2026 manual, selected models) Outdoor coil overheat protection in cooling
21 P9 Inverter (2026 manual, selected models) Indoor coil overheat protection in heating
22 PC Inverter (2026 manual, selected models) Outdoor temperature too low for cooling (protection)
23 PH Inverter (2026 manual, selected models) Outdoor temperature too high for heating (protection)
25 EE Inverter (2026 manual, selected models) Indoor unit EE fault
26 E1 Inverter (2026 manual, selected models) Indoor fan fault
27 E2 Inverter (2026 manual, selected models) Indoor fan zero-crossing detection fault
28 E3 Inverter (2026 manual, selected models) Indoor coil temperature sensor fault
29 E4 Inverter (2026 manual, selected models) Indoor ambient temperature sensor fault
31 L1 Inverter (2026 manual, selected models) Drive bus voltage too high (protection)
32 L2 Inverter (2026 manual, selected models) Drive bus voltage too low (protection)
33 L3 Inverter (2026 manual, selected models) Drive phase current overload fault
34 L4 Inverter (2026 manual, selected models) Phase current sampling abnormal
35 FC Inverter (2026 manual, selected models) Filter clean reminder (not a fault). Onida: press SLEEP 4 times within 8 seconds to reset

हिंदी में

डिस्प्ले पर कोड नहीं, सिर्फ़ बत्ती झपक रही है? बत्ती कितनी बार झपकती है, उसे गिनें। झपकने के बाद थोड़ा रुकती है, फिर दोबारा शुरू होती है। दो रुकावटों के बीच की गिनती ही आपका कोड है।

  1. ऊपर सही बत्ती चुनें और हर झपक पर बड़ा बटन दबाएं, या गिनती लिखें।
  2. मशीन को दीवार के स्विच से बंद करें। कोड और झपकने की गिनती लिख लें, फिर अधिकृत सर्विस को बुलाएं। यूनिट खुद न खोलें।

Questions people ask

How do I count Onida AC light blinks?

Watch the light for a full cycle: it flashes a number of times, pauses, then repeats. Count the flashes between two pauses. Count two or three cycles to be sure.

Can I fix a blinking light fault myself?

Switch off the unit at the wall and note the code and the number of flashes. Onida says: if the power cord is overheating or damaged, there is an abnormal sound, the air switch trips often, there is a burning smell or the indoor unit is leaking, turn off the AC, disconnect the power at once and contact the dealer or a qualified professional. For any code not in its tables, Onida says to contact qualified professionals.

Sources

Last checked:

↑