Carrier AC Error Codes: EC, CL, nF, E1, E5 and Full Window AC List

By FaultDecode · Checked against Carrier's official documents · Updated · How we check

48 Carrier codes on this page.

Every row here comes from a Carrier user manual on Carrier Midea India's website (2024 editions). Carrier uses different codes on different ranges, and the same code can mean different things: CL is a filter cleaning reminder on Xcel Indus, Xtreme and Durawhite Pro+ split ACs, but it means self clean is running on the Durawhite Pro+ / Ester+ 12K/18K models. E5 is a fan motor protection on Xtreme fixed-speed models and a gas leak on Durawhite Pro+ / Ester+ inverter models. Find your model name first, then read the row for that model.

Safety: Carrier's manuals say not to repair the AC yourself because it can cause electric shock or fire, and that any repair should be done by an authorised dealer or licensed service provider. For EC or a gas leakage code, switch off and call Carrier service.

How to see the code

  1. Find your model name on the indoor unit sticker or the manual cover (for example Xcel Indus, Xtreme, Durawhite Pro+, Estrella).
  2. Read the 2-character code on the indoor unit display.
  3. On the Estrella Inverter window AC you can also count the outdoor light flashes; the count is given next to each code.
  4. Match the code in the rows for your model. If your model is not listed, check your own manual.

Only a blinking light? Use the Carrier blink decoder: tap once per flash and see the code.

How to check the error code on other AC brands

Carrier AC error code list

CodeModel typeMeaningWhat to do
EC (run light flashes 7 times, timer light off) Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+) Refrigerant leakage detected (optional feature) · full fix EC on a Carrier split AC means refrigerant leakage. Carrier's user manuals for Xcel Indus, Xtreme and Durawhite Pro+ / Ester+ split ACs say the indoor unit automatically shows EC when it detects a refrigerant leak; the timer light turns off and the run light flashes 7 times. It is an optional feature, so not every model has it. There is no home fix. Switch off the AC and call Carrier service.
CL (run and timer lights flash) Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+) Filter cleaning reminder after 240 hours of use (not a fault) · full fix CL on a Carrier AC is not a fault. On Xcel Indus, Xtreme and Durawhite Pro+ / Ester+ split ACs that have the optional air filter reminder, Carrier's manual says CL flashes after 240 hours of use as a reminder to clean the filter; the run and timer lights may flash too. Clean the filter, then press the LED button on the remote 4 times (or the MANUAL CONTROL button 3 times) to reset it. On Durawhite Pro+ / Ester+ 12K/18K models, CL also shows while the self clean function runs.
nF (run and timer lights flash) Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+) Filter replacement reminder after 2,880 hours of use (not a fault) · full fix nF on a Carrier split AC is not an error. Carrier's manuals for Xcel Indus, Xtreme and Durawhite Pro+ / Ester+ say that on units with the optional filter reminder, the display flashes nF after 2,880 hours of use as a reminder to replace the filter; the run and timer lights may flash too. After the filter is replaced, press the LED button on the remote 4 times, or the MANUAL CONTROL button 3 times, to reset it.
E0, E1, E2… (also P1, P2, P3… and F1, F2, F3…) Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+) Error code. Wait about 10 minutes; if it stays, power off and on; if it persists, call service —
E5/H6 Split AC, Xtreme fixed speed 12K/18K Indoor unit fan motor protection · full fix E5 on a Carrier AC depends on the model. On Durawhite Pro+ / Ester+ inverter models, Carrier's manual says E5 shows on the indoor unit when gas leaks from the AC, and it can be checked after the AC has run for 1 hour. On Xtreme fixed-speed split ACs, E5 (also H6) is indoor unit fan motor protection. On the Estrella Inverter window AC table, E5 is no-refrigerant protection, marked reserved. In every case, switch off and call Carrier service.
E1 (shows with set temperature, every 4 seconds) Split AC, Xtreme fixed speed 12K/18K Room sensor error · full fix E1 on a Carrier AC is usually a room temperature sensor error. The Xtreme fixed-speed split AC manual lists E1 as a room sensor error (the display shows E1 and the set temperature by turns, every 4 seconds). The Estrella window AC (fixed speed) manual lists E1 as room sensor failure or missing; the compressor then runs 20 minutes on and 7 minutes off. The Estrella Inverter (E) window manual also lists E1 as a room sensor fault. Only the other Estrella Inverter window manual (ACW5PR07501) lists E1 as an indoor fan fault, marked reserved. The sensor is a technician repair.
E2 (shows with set temperature, every 4 seconds) Split AC, Xtreme fixed speed 12K/18K Evaporator sensor error —
dF Split AC, Xtreme fixed speed 12K/18K Frost protection —
CL (shown during self clean) Split AC, Durawhite Pro+ / Ester+ 12K/18K Self clean running (press Self Clean for 5 seconds to start) · full fix CL on a Carrier AC is not a fault. On Xcel Indus, Xtreme and Durawhite Pro+ / Ester+ split ACs that have the optional air filter reminder, Carrier's manual says CL flashes after 240 hours of use as a reminder to clean the filter; the run and timer lights may flash too. Clean the filter, then press the LED button on the remote 4 times (or the MANUAL CONTROL button 3 times) to reset it. On Durawhite Pro+ / Ester+ 12K/18K models, CL also shows while the self clean function runs.
E5 (inverter models only) Split AC, Durawhite Pro+ / Ester+ 12K/18K Gas (refrigerant) leakage · full fix E5 on a Carrier AC depends on the model. On Durawhite Pro+ / Ester+ inverter models, Carrier's manual says E5 shows on the indoor unit when gas leaks from the AC, and it can be checked after the AC has run for 1 hour. On Xtreme fixed-speed split ACs, E5 (also H6) is indoor unit fan motor protection. On the Estrella Inverter window AC table, E5 is no-refrigerant protection, marked reserved. In every case, switch off and call Carrier service.
E1 (blinks; compressor runs 20 min on, 7 min off) Window AC, Estrella (fixed speed) Room sensor failure or missing. Carrier: check the sensor, contact your Carrier dealer if not fixed · full fix E1 on a Carrier AC is usually a room temperature sensor error. The Xtreme fixed-speed split AC manual lists E1 as a room sensor error (the display shows E1 and the set temperature by turns, every 4 seconds). The Estrella window AC (fixed speed) manual lists E1 as room sensor failure or missing; the compressor then runs 20 minutes on and 7 minutes off. The Estrella Inverter (E) window manual also lists E1 as a room sensor fault. Only the other Estrella Inverter window manual (ACW5PR07501) lists E1 as an indoor fan fault, marked reserved. The sensor is a technician repair.
E2 (blinks; compressor runs 20 min on, 7 min off) Window AC, Estrella (fixed speed), R32 models only Coil sensor failure or missing. Carrier: check the sensor, contact your Carrier dealer if not fixed —
E1 Window AC, Estrella Inverter (E) Room sensor fault · full fix E1 on a Carrier AC is usually a room temperature sensor error. The Xtreme fixed-speed split AC manual lists E1 as a room sensor error (the display shows E1 and the set temperature by turns, every 4 seconds). The Estrella window AC (fixed speed) manual lists E1 as room sensor failure or missing; the compressor then runs 20 minutes on and 7 minutes off. The Estrella Inverter (E) window manual also lists E1 as a room sensor fault. Only the other Estrella Inverter window manual (ACW5PR07501) lists E1 as an indoor fan fault, marked reserved. The sensor is a technician repair.
E2 Window AC, Estrella Inverter (E) Coil sensor fault —
DF Window AC, Estrella Inverter (E) Defrost protection error —
EE (outdoor light flashes 25) Window AC, Estrella Inverter Indoor unit EE (memory) fault —
E1 (outdoor light flashes 26) Window AC, Estrella Inverter Indoor fan fault (marked reserved) · full fix E1 on a Carrier AC is usually a room temperature sensor error. The Xtreme fixed-speed split AC manual lists E1 as a room sensor error (the display shows E1 and the set temperature by turns, every 4 seconds). The Estrella window AC (fixed speed) manual lists E1 as room sensor failure or missing; the compressor then runs 20 minutes on and 7 minutes off. The Estrella Inverter (E) window manual also lists E1 as a room sensor fault. Only the other Estrella Inverter window manual (ACW5PR07501) lists E1 as an indoor fan fault, marked reserved. The sensor is a technician repair.
E2 (outdoor light flashes 27) Window AC, Estrella Inverter Indoor fan zero-crossing detection abnormal (marked reserved) —
E3 (outdoor light flashes 28) Window AC, Estrella Inverter Indoor coil fault and sensor fault · full fix E3 on a Carrier Estrella Inverter window AC means "indoor coil fault and sensor fault", according to the Protection / Error table in Carrier's manual. The outdoor light flashes 28 times. The manual gives no home fix, so call Carrier service. Carrier's split AC manuals do not give a meaning for E3.
E4 (outdoor light flashes 29) Window AC, Estrella Inverter Indoor ambient temperature sensor fault · full fix E4 on a Carrier Estrella Inverter window AC means an indoor ambient temperature sensor fault, according to the Protection / Error table in Carrier's manual. The outdoor light flashes 29 times. The manual gives no home fix, so call Carrier service. Carrier's split AC manuals do not give a meaning for E4.
E5 Window AC, Estrella Inverter No refrigerant protection (marked reserved) · full fix E5 on a Carrier AC depends on the model. On Durawhite Pro+ / Ester+ inverter models, Carrier's manual says E5 shows on the indoor unit when gas leaks from the AC, and it can be checked after the AC has run for 1 hour. On Xtreme fixed-speed split ACs, E5 (also H6) is indoor unit fan motor protection. On the Estrella Inverter window AC table, E5 is no-refrigerant protection, marked reserved. In every case, switch off and call Carrier service.
E0 (outdoor light flashes 1) Window AC, Estrella Inverter Outdoor unit EE (memory) fault —
E6 (outdoor light flashes 2) Window AC, Estrella Inverter Indoor and outdoor unit communication fault —
F1 (outdoor light flashes 4) Window AC, Estrella Inverter Compressor starting abnormal (phase failure, reverse) —
F2 (outdoor light flashes 5) Window AC, Estrella Inverter Compressor out-of-step fault —
F3 (outdoor light flashes 6) Window AC, Estrella Inverter IPM module fault —
F4 (outdoor light flashes 7) Window AC, Estrella Inverter Compressor shell top fault / protection (marked reserved) —
F5 (outdoor light flashes 8) Window AC, Estrella Inverter Discharge temperature sensor fault —
F6 (outdoor light flashes 9) Window AC, Estrella Inverter Suction temperature sensor fault (marked reserved) —
F7 (outdoor light flashes 10) Window AC, Estrella Inverter Outdoor coil temperature sensor fault —
F8 (outdoor light flashes 11) Window AC, Estrella Inverter Outdoor ambient temperature sensor fault —
F9 (outdoor light flashes 12) Window AC, Estrella Inverter Outdoor DC fan fault (marked reserved) —
E8 Window AC, Estrella Inverter Outdoor communication fault —
P1 (outdoor light flashes 13) Window AC, Estrella Inverter Outdoor unit AC current protection —
P2 (outdoor light flashes 14) Window AC, Estrella Inverter Compressor phase current protection —
P3 (outdoor light flashes 15) Window AC, Estrella Inverter Outdoor unit AC voltage too high or too low protection —
P4 (outdoor light flashes 16) Window AC, Estrella Inverter DC voltage too high or too low protection —
P5 (outdoor light flashes 17) Window AC, Estrella Inverter IPM over-temperature protection —
P6 (outdoor light flashes 18) Window AC, Estrella Inverter Discharge temperature overheat protection —
P7 (outdoor light flashes 19) Window AC, Estrella Inverter Cooling: indoor coil anti-freezing protection —
P8 (outdoor light flashes 20) Window AC, Estrella Inverter Cooling: outdoor coil overheat protection —
P9 (outdoor light flashes 21) Window AC, Estrella Inverter Heating: indoor coil overheat protection —
PC (outdoor light flashes 22) Window AC, Estrella Inverter Cooling: outdoor temperature too low protection —
PH (outdoor light flashes 23) Window AC, Estrella Inverter Heating: outdoor temperature too high protection —
L1 (outdoor light flashes 31) Window AC, Estrella Inverter Drive bus voltage too high protection —
L2 (outdoor light flashes 32) Window AC, Estrella Inverter Drive bus voltage too low protection —
L3 (outdoor light flashes 33) Window AC, Estrella Inverter Drive phase current overload fault —
L4 (outdoor light flashes 34) Window AC, Estrella Inverter Phase current sampling abnormal —

No code, but a problem?

Good to know

हिंदी में

Carrier के अलग-अलग मॉडल में एक ही कोड का मतलब अलग हो सकता है। Xcel Indus, Xtreme और Durawhite Pro+ स्प्लिट AC में EC का मतलब गैस लीक है, CL और nF फ़िल्टर साफ़ करने या बदलने की याद है।

  1. पहले AC के स्टिकर या मैनुअल से मॉडल का नाम देखें।
  2. EC या गैस लीक कोड आए तो AC बंद करें और Carrier सर्विस (1800 1033 333) बुलाएं।
  3. CL आए तो फ़िल्टर साफ़ करें, nF आए तो फ़िल्टर बदलें। फिर रिमोट का LED बटन 4 बार (या MANUAL CONTROL बटन 3 बार) दबाएं।
  4. दूसरे E, P या F कोड पर 10 मिनट रुकें, फिर बिजली बंद-चालू करें। कोड रहे तो सर्विस बुलाएं।

Questions people ask

What is EC error in a Carrier AC?

On Carrier Xcel Indus, Xtreme and Durawhite Pro+ split ACs, the manual says the indoor unit shows EC when it detects refrigerant leakage (an optional feature). The timer light turns off and the run light flashes 7 times. Switch off and call Carrier service.

What does CL mean on a Carrier AC?

On Xcel Indus, Xtreme and Durawhite Pro+ split ACs it is a reminder to clean the filter after 240 hours of use. On Durawhite Pro+ / Ester+ 12K/18K models the manual says the display shows CL while self clean is running.

What is nF on a Carrier AC?

A reminder to replace the filter after 2,880 hours of use. Carrier says to reset it by pressing the LED button on the remote 4 times, or the MANUAL CONTROL button 3 times.

What is E1 error in a Carrier AC?

On Xtreme fixed-speed split ACs, Estrella window ACs and the Estrella Inverter (E) window AC, E1 is a room sensor error. In the other Estrella Inverter window manual (ACW5PR07501), E1 is an indoor fan fault marked reserved.

Sources