Carrier AC blinking light codes
No code on the display, only a blinking light? Some Carrier models also show the fault as a number of flashes. Count them and pick the light below. Every row comes from the Carrier AC error code list. Other brand? See AC light blinking on every brand.
Safety: Carrier's manuals say not to repair the AC yourself because it can cause electric shock or fire, and that any repair should be done by an authorised dealer or licensed service provider. For EC or a gas leakage code, switch off and call Carrier service.
Blink decoder
Tap the big button once for every flash, or type the number.
Pick the light and count the flashes.
How to count the flashes
- On the Estrella Inverter window AC you can also count the outdoor light flashes; the count is given next to each code.
Outdoor light flashes
| Flashes | Code | Model type | Meaning |
|---|---|---|---|
| 1 | E0 | Window AC, Estrella Inverter | Outdoor unit EE (memory) fault |
| 2 | E6 | Window AC, Estrella Inverter | Indoor and outdoor unit communication fault |
| 4 | F1 | Window AC, Estrella Inverter | Compressor starting abnormal (phase failure, reverse) |
| 5 | F2 | Window AC, Estrella Inverter | Compressor out-of-step fault |
| 6 | F3 | Window AC, Estrella Inverter | IPM module fault |
| 7 | F4 | Window AC, Estrella Inverter | Compressor shell top fault / protection (marked reserved) |
| 8 | F5 | Window AC, Estrella Inverter | Discharge temperature sensor fault |
| 9 | F6 | Window AC, Estrella Inverter | Suction temperature sensor fault (marked reserved) |
| 10 | F7 | Window AC, Estrella Inverter | Outdoor coil temperature sensor fault |
| 11 | F8 | Window AC, Estrella Inverter | Outdoor ambient temperature sensor fault |
| 12 | F9 | Window AC, Estrella Inverter | Outdoor DC fan fault (marked reserved) |
| 13 | P1 | Window AC, Estrella Inverter | Outdoor unit AC current protection |
| 14 | P2 | Window AC, Estrella Inverter | Compressor phase current protection |
| 15 | P3 | Window AC, Estrella Inverter | Outdoor unit AC voltage too high or too low protection |
| 16 | P4 | Window AC, Estrella Inverter | DC voltage too high or too low protection |
| 17 | P5 | Window AC, Estrella Inverter | IPM over-temperature protection |
| 18 | P6 | Window AC, Estrella Inverter | Discharge temperature overheat protection |
| 19 | P7 | Window AC, Estrella Inverter | Cooling: indoor coil anti-freezing protection |
| 20 | P8 | Window AC, Estrella Inverter | Cooling: outdoor coil overheat protection |
| 21 | P9 | Window AC, Estrella Inverter | Heating: indoor coil overheat protection |
| 22 | PC | Window AC, Estrella Inverter | Cooling: outdoor temperature too low protection |
| 23 | PH | Window AC, Estrella Inverter | Heating: outdoor temperature too high protection |
| 25 | EE | Window AC, Estrella Inverter | Indoor unit EE (memory) fault |
| 26 | E1 | Window AC, Estrella Inverter | Indoor fan fault (marked reserved) · full fix |
| 27 | E2 | Window AC, Estrella Inverter | Indoor fan zero-crossing detection abnormal (marked reserved) |
| 28 | E3 | Window AC, Estrella Inverter | Indoor coil fault and sensor fault · full fix |
| 29 | E4 | Window AC, Estrella Inverter | Indoor ambient temperature sensor fault · full fix |
| 31 | L1 | Window AC, Estrella Inverter | Drive bus voltage too high protection |
| 32 | L2 | Window AC, Estrella Inverter | Drive bus voltage too low protection |
| 33 | L3 | Window AC, Estrella Inverter | Drive phase current overload fault |
| 34 | L4 | Window AC, Estrella Inverter | Phase current sampling abnormal |
Run light flashes
Other light patterns
- CL (run and timer lights flash) · Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+): Filter cleaning reminder after 240 hours of use (not a fault)
- nF (run and timer lights flash) · Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+): Filter replacement reminder after 2,880 hours of use (not a fault)
- E1 (blinks; compressor runs 20 min on, 7 min off) · Window AC, Estrella (fixed speed): Room sensor failure or missing. Carrier: check the sensor, contact your Carrier dealer if not fixed
- E2 (blinks; compressor runs 20 min on, 7 min off) · Window AC, Estrella (fixed speed), R32 models only: Coil sensor failure or missing. Carrier: check the sensor, contact your Carrier dealer if not fixed
हिंदी में
डिस्प्ले पर कोड नहीं, सिर्फ़ बत्ती झपक रही है? बत्ती कितनी बार झपकती है, उसे गिनें। झपकने के बाद थोड़ा रुकती है, फिर दोबारा शुरू होती है। दो रुकावटों के बीच की गिनती ही आपका कोड है।
- ऊपर सही बत्ती चुनें और हर झपक पर बड़ा बटन दबाएं, या गिनती लिखें।
- मशीन को दीवार के स्विच से बंद करें। कोड और झपकने की गिनती लिख लें, फिर अधिकृत सर्विस को बुलाएं। यूनिट खुद न खोलें।
Questions people ask
How do I count Carrier AC light blinks?
Watch the light for a full cycle: it flashes a number of times, pauses, then repeats. Count the flashes between two pauses. Count two or three cycles to be sure.
Can I fix a blinking light fault myself?
Switch off the unit at the wall and note the code and the number of flashes. Carrier's manuals say not to repair the AC yourself because it can cause electric shock or fire, and that any repair should be done by an authorised dealer or licensed service provider. For EC or a gas leakage code, switch off and call Carrier service.
Sources
- Carrier Xcel Indus split AC user manual (2024): EC, CL, nF p.8, filter reminders p.13, troubleshooting p.17
- Carrier Xtreme split AC user manual (2024): same EC, CL and nF text
- Carrier Durawhite Pro+ / Ester+ split AC user manual (2024): same EC, CL and nF text
- Carrier Xtreme fixed-speed 12K/18K combined manual (2024): Error signals on the display, manual p.11
- Carrier Durawhite Pro+ / Ester+ 12K/18K combined manual (2024): Self clean and Gas leakage, manual p.13
- Carrier Estrella window AC (fixed speed) manual (2024): E1 and E2 (E2 on R32 models)
- Carrier Estrella Inverter window AC manual (2024): Protection / Error table, manual p.15
- Carrier Estrella Inverter (E) window AC manual (2024): Error code table, manual p.15
- Carrier Midea India: FAQ and manuals (all manuals listed here)
Last checked: