| H00 | No fault stored in memory | — |
| H11 | Indoor and outdoor units not communicating · full fix | H11 on a Panasonic inverter AC means indoor / outdoor abnormal communication. Panasonic's self-diagnosis page says to note the code and contact a qualified service technician for inspection and repair. You can read the stored code with the remote: hold the CHECK button for about 5 seconds and step through the codes with the TIMER arrows until the unit beeps. |
| H12 | Indoor unit capacity does not match | — |
| H14 | Indoor intake air temperature sensor fault | — |
| H15 | Compressor temperature sensor fault | — |
| H16 | Outdoor current transformer fault | — |
| H17 | Outdoor suction temperature sensor fault | — |
| H19 | Indoor fan motor locked | — |
| H21 | Indoor float switch malfunction | — |
| H23 | Indoor heat exchanger temperature sensor 1 fault | — |
| H24 | Indoor heat exchanger temperature sensor 2 fault | — |
| H25 | Indoor ion device fault | — |
| H26 | Negative ion fault | — |
| H27 | Outdoor air temperature sensor fault | — |
| H28 | Outdoor heat exchanger temperature sensor 1 fault | — |
| H30 | Outdoor discharge pipe temperature sensor fault | — |
| H31 | Swimming pool sensor fault | — |
| H32 | Outdoor heat exchanger temperature sensor 2 fault | — |
| H33 | Indoor and outdoor units misconnected | — |
| H34 | Outdoor heat sink temperature sensor fault | — |
| H35 | Indoor/outdoor water adverse current fault | — |
| H36 | Outdoor gas pipe temperature sensor fault | — |
| H37 | Outdoor liquid pipe temperature sensor fault | — |
| H38 | Indoor and outdoor brand code mismatch | — |
| H39 | Abnormal indoor operating or standby unit | — |
| H41 | Wiring or piping connection fault | — |
| H50 | Ventilation fan motor locked | — |
| H51 | Ventilation fan motor locked | — |
| H52 | Left-right limit switch fixing fault | — |
| H58 | Indoor gas sensor fault | — |
| H59 | Eco sensor fault | — |
| H64 | Outdoor high-pressure sensor fault | — |
| H67 | nanoe fault | — |
| H70 | Light sensor fault | — |
| H71 | Control board internal DC cooling fan fault | — |
| H72 | Tank temperature sensor fault | — |
| H79 | Wireless LAN module write error | — |
| H85 | Indoor unit and wireless LAN module communication fault | — |
| H97 | Outdoor fan motor locked | — |
| H98 | Indoor high-pressure protection | — |
| H99 | Indoor operating unit freeze protection | — |
| F11 | 4-way valve switching fault | — |
| F16 | Total running current protection | — |
| F17 | Indoor standby unit freezing fault | — |
| F18 | Dry circuit blocked | — |
| F87 | Control box overheat protection | — |
| F90 | PFC circuit protection or compressor microcomputer communication error | — |
| F91 | Refrigerant cycle fault | — |
| F93 | Abnormal compressor speed | — |
| F94 | Compressor discharge pressure protection | — |
| F95 | Outdoor high-pressure protection (cooling) | — |
| F96 | Power transistor module overheating protection | — |
| F97 | Compressor overheating protection | — |
| F98 | Total running current protection | — |
| F99 | Outdoor DC peak detection | — |