| 1 flash (upper operation lamp, every 0.5 s) | FAQ flash table | Room temperature thermistor short or open circuit |
| 2 flashes (upper operation lamp, then 2.5 s off) | FAQ flash table | Indoor coil thermistor short or open circuit |
| 3 flashes (upper operation lamp, then 2.5 s off) | FAQ flash table | Serial signal (Mitsubishi lists the condition as no fan speed feedback signal during indoor fan operation) |
| 4 flashes (upper operation lamp) | Inverter only (FAQ flash table) | Indoor fan motor (Mitsubishi lists the condition as indoor PCB failure) |
| 5 flashes (upper operation lamp) | Inverter only (FAQ flash table) | Indoor control system: compressor stopped after 3 over-current or start-up failure protections within 1 minute of start-up |
| 6 flashes (upper operation lamp) | Inverter only (FAQ flash table) | Outdoor thermistor short or open circuit |
| 7 flashes (upper operation lamp) | Inverter only (FAQ flash table) | Outdoor control system: indoor or outdoor PCB failure |
| 11 flashes (upper operation lamp) | FAQ flash table | Indoor fan motor: no fan speed feedback signal for 12 seconds of indoor fan operation |
| 14 flashes (upper operation lamp) | FAQ flash table | Refrigerant circuit: unit pumped down for a long time, low refrigerant, short cycling, or outdoor fan motor locked |
| 00 (remote CHECK display) | Indoor unit (MSY-GR, MSY-JS remote check) | No error (normal) |
| E6/E7 (remote CHECK display) | Indoor unit (MSY-GR, MSY-JS remote check) | Serial signal (abnormal point; read with the remote CHECK button) |
| Fb (remote CHECK display) | Indoor unit (MSY-GR, MSY-JS remote check) | Indoor control system |
| P1 (remote CHECK display) | Indoor unit (MSY-GR, MSY-JS remote check) | Room temperature thermistor |
| P2/P9 (remote CHECK display) | Indoor unit (MSY-GR, MSY-JS remote check) | Indoor coil thermistor |
| Pb (remote CHECK display) | Indoor unit (MSY-GR, MSY-JS remote check) | Indoor fan motor |
| E8/E9/EC (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Indoor/outdoor communication, receiving error (read with the remote CHECK button) |
| FC (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Nonvolatile memory data |
| Fd (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Different voltage |
| P8 (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | 4-way valve / pipe temperature |
| PL (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Outdoor refrigerant system |
| U3 (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Discharge temperature thermistor |
| U4 (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Outdoor thermistor: defrost, fin, P.C. board, ambient or outdoor heat exchanger temperature |
| UE (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Stop valve (closed valve) |
| UP (remote CHECK display) | Outdoor unit (MSY-GR, MSY-JS remote check) | Outdoor power system |