E6 Error in Lloyd Inverter AC: Indoor and Outdoor Units Not Communicating

Quick answer

E6 on a Lloyd inverter split AC means the indoor and outdoor units are not communicating. On models without a display, the indoor LED flashes 2 times. Lloyd's manual gives the meaning but no home fix. Switch off the AC and call Lloyd service.

What E6 means on a Lloyd AC

Lloyd's manual lists E6 only in the inverter split AC table, so if you have a non-inverter AC, check your own manual.

If your AC has no display

Count the indoor LED flashes from the second cycle. E6 is 2 flashes.

What the outdoor unit shows

In Lloyd's inverter table (owner's manual, p.48), the outdoor unit light also flashes 2 times for this code, the same count as the indoor LED. Lloyd says to count the flashes from the second cycle.

Check it with Intelligent Diagnostic (selected models)

Some Lloyd ACs have an Intelligent Diagnostic test (owner's manual, p.37). Press DISPLAY on the remote six times: all indicators on the indoor display blink and the buzzer beeps four times. Then press DISPLAY twice more, or the emergency button, to start the test. If you press nothing for three minutes, the AC goes back to normal mode.

If the test passes, the indoor display shows go, the green Timer LED stays on until you reset the power or switch on from the remote, and the buzzer gives a long beep. If it fails, the display shows ng, the red Sleep LED blinks according to the error code until reset, and the buzzer beeps 5 times. Lloyd notes that if the AC was running before, you should switch it off for five minutes and then on again.

What to do

Switch off the AC with the remote and at the MCB.

After you switch it off

Lloyd's manual (p.37) says the AC remembers its last settings after a power failure: set temperature, mode, fan speed, swing, silent and Wi-Fi resume when power returns. Its malfunction table (p.54) also says that if the unit is restarted immediately after stopping, wait 3 minutes and then turn it on again.

Safety: Do not open the units or touch the cable between them. Lloyd's manual says to cut off the power supply before any work, not to repair the AC yourself, and to call a qualified technician.

Fix it step by step

  1. Check that your AC is a Lloyd inverter model. E6 is listed in the inverter table.
  2. If there is no display, count the indoor LED flashes from the second cycle: E6 is 2 flashes.
  3. Switch off the AC with the remote and at the MCB.
  4. If your model has Intelligent Diagnostic, you can run it from the remote (DISPLAY six times, then twice more) and tell the technician whether it showed go or ng.
  5. Call Lloyd service and tell them the code.

Still showing E6?

  • Lloyd customer care: 0804-577-5666 (printed in the owner's manual).

हिंदी में

Lloyd इन्वर्टर AC में E6 का मतलब है अंदर और बाहर वाली यूनिट आपस में बात नहीं कर रहीं। स्क्रीन न हो तो अंदर की LED 2 बार ब्लिंक करती है।

  1. AC बंद करें और MCB बंद करें।
  2. Lloyd सर्विस बुलाएं और कोड बताएं।
  3. तार या यूनिट खुद न छुएं।
  4. रिमोट पर DISPLAY छह बार, फिर दो बार और दबाकर (जिन मॉडल में यह फ़ीचर है) जांच चलाएं: go मतलब ठीक, ng मतलब खराबी।

Questions people ask

What is E6 error in a Lloyd inverter AC?

Lloyd's manual lists E6 as a communication fault between the indoor and outdoor units. The indoor LED flashes 2 times.

How do I run Lloyd's self-test?

On models that have Intelligent Diagnostic, press DISPLAY on the remote six times, then twice more (or press the emergency button). go means the test passed; ng means it found a fault. Lloyd says this is an optional feature on selected models.

Does the outdoor unit also blink for E6?

Yes. Lloyd's inverter table lists 2 flashes on the outdoor unit light as well as 2 on the indoor LED.