Quick answer
E3 on a Lloyd AC points to a coil sensor, but which one depends on the model. On a Lloyd inverter split AC, E3 is an indoor coil fault and coil sensor fault. On selected non-inverter split ACs, E3 is an outdoor coil temperature sensor fault. Lloyd's manual gives no home fix. Switch off and call Lloyd service.
What E3 means on your Lloyd AC
So first check whether your AC is an inverter or non-inverter model.
If your AC has no display
On an inverter model, count the indoor LED flashes from the second cycle: E3 is 28 flashes. Be careful on a non-inverter model, where 28 flashes means E2 (indoor coil temperature sensor fault) instead.
What the outdoor unit shows
In Lloyd's inverter table (owner's manual, p.48), the outdoor unit light also flashes 28 times for this code, the same count as the indoor LED. Lloyd says to count the flashes from the second cycle. Lloyd's non-inverter table gives no flash count for E3.
Check it with Intelligent Diagnostic (selected models)
Some Lloyd ACs have an Intelligent Diagnostic test (owner's manual, p.37). Press DISPLAY on the remote six times: all indicators on the indoor display blink and the buzzer beeps four times. Then press DISPLAY twice more, or the emergency button, to start the test. If you press nothing for three minutes, the AC goes back to normal mode.
If the test passes, the indoor display shows go, the green Timer LED stays on until you reset the power or switch on from the remote, and the buzzer gives a long beep. If it fails, the display shows ng, the red Sleep LED blinks according to the error code until reset, and the buzzer beeps 5 times. Lloyd notes that if the AC was running before, you should switch it off for five minutes and then on again.
What to do
Switch off the AC with the remote and at the MCB. Call Lloyd customer care on 0804-577-5666 and tell them the code and your model type.
After you switch it off
Lloyd's manual (p.37) says the AC remembers its last settings after a power failure: set temperature, mode, fan speed, swing, silent and Wi-Fi resume when power returns. Its malfunction table (p.54) also says that if the unit is restarted immediately after stopping, wait 3 minutes and then turn it on again.
Safety: Lloyd's manual says to cut off the power supply before any work, not to repair the AC yourself, and to call a qualified technician.
Fix it step by step
0 of 5 done
- Check whether your Lloyd AC is an inverter or a non-inverter model.
- If there is no display on an inverter model, count the indoor LED flashes from the second cycle: E3 is 28 flashes.
- Switch off the AC with the remote and at the MCB.
- If your model has Intelligent Diagnostic, you can run it from the remote (DISPLAY six times, then twice more) and tell the technician whether it showed go or ng.
- Call Lloyd service and tell them the code and your model type.
Still showing E3?
- Lloyd customer care: 0804-577-5666 (printed in the owner's manual).
हिंदी में
Lloyd AC में E3 का मतलब कॉइल सेंसर की खराबी है। इन्वर्टर AC में अंदर वाली कॉइल और उसका सेंसर, कुछ नॉन-इन्वर्टर AC में बाहर वाली कॉइल का तापमान सेंसर।
- देखें आपका AC इन्वर्टर है या नॉन-इन्वर्टर।
- AC बंद करें और MCB बंद करें।
- Lloyd सर्विस बुलाएं और कोड बताएं।
- AC खुद न खोलें।
- रिमोट पर DISPLAY छह बार, फिर दो बार और दबाकर (जिन मॉडल में यह फ़ीचर है) जांच चलाएं: go मतलब ठीक, ng मतलब खराबी।
Questions people ask
Is E3 the same on every Lloyd AC?
No. Lloyd's manual lists E3 as an indoor coil and coil sensor fault on inverter split ACs, and as an outdoor coil temperature sensor fault on selected non-inverter split ACs.
My Lloyd inverter AC LED blinks 28 times. What does it mean?
28 indoor LED flashes on a Lloyd inverter split AC is E3. On a non-inverter model, 28 flashes is E2 (indoor coil temperature sensor fault).
How do I run Lloyd's self-test?
On models that have Intelligent Diagnostic, press DISPLAY on the remote six times, then twice more (or press the emergency button). go means the test passed; ng means it found a fault. Lloyd says this is an optional feature on selected models.
Did this fix your problem? क्या इससे मदद मिली?
What went wrong?
Thanks. This helps us fix our guides. धन्यवाद!
Sources
- Lloyd split AC owner's manual (Havells): Intelligent Diagnostic p.37, Errors & Troubleshooting p.48, Malfunction analysis p.54
- Havells: manuals and documents (Lloyd)
Last checked: