Lloyd AC blinking light codes
No code on the display, only a blinking light? Some Lloyd models also show the fault as a number of flashes. Count them and pick the light below. Every row comes from the Lloyd AC error code list. Other brand? See AC light blinking on every brand.
Safety: Lloyd's manual says to cut off the power supply before any work, not to repair the AC yourself, and to call a qualified technician. For E5 (refrigerant leak), switch off and call Lloyd service.
Blink decoder
Tap the big button once for every flash, or type the number.
Pick the light and count the flashes.
How to count the flashes
- If there is no display, count the indoor LED flashes. Lloyd's manual says to count from the second cycle of flashes.
- Inverter models may also flash a light on the outdoor unit; the count is listed below next to each code.
Indoor LED flashes
| Flashes | Code | Model type | Meaning | What to do |
|---|---|---|---|---|
| 1 | E0 | Inverter split | Outdoor unit memory (EE) fault | — |
| 2 | E6 | Inverter split | Indoor and outdoor units not communicating · full fix | — |
| 3 | E9 / EF | Inverter split | Wi-Fi module fault (selected models) | — |
| 4 | F1 | Inverter split | Compressor start abnormal or phase failure | — |
| 5 | F2 | Inverter split | Compressor out-of-step fault | — |
| 6 | F3 | Inverter split | IPM (inverter power module) fault | — |
| 7 | F4 | Inverter split | Compressor shell top fault or protection | — |
| 8 | F5 | Inverter split | Discharge temperature sensor fault | — |
| 9 | F6 | Inverter split | Suction temperature sensor fault (selected models) | — |
| 10 | F7 | Inverter split | Outdoor coil temperature sensor fault | — |
| 11 | F8 | Inverter split | Outdoor air temperature sensor fault | — |
| 12 | F9 | Inverter split | Outdoor DC fan fault (selected models) | — |
| 13 | P1 | Inverter split | Outdoor unit AC current protection | — |
| 14 | P2 | Inverter split | Compressor phase current protection | — |
| 15 | P3 | Inverter split | Outdoor unit supply voltage too high or too low · full fix | — |
| 16 | P4 | Inverter split | DC voltage too high or too low | — |
| 17 | P5 | Inverter split | IPM over-temperature protection | — |
| 18 | P6 | Inverter split | Discharge temperature overheat protection | — |
| 19 | P7 | Inverter split | Indoor coil anti-freeze protection in cooling | The AC is defrosting the indoor coil in cooling; the code shows for some time while frost is removed |
| 19 | dF | Split (non-inverter) | Indoor defrost protection in cooling · full fix | The AC is defrosting the indoor coil in cooling; the code shows for some time while frost is removed |
| 20 | P8 | Inverter split | Outdoor coil overheat protection in cooling | — |
| 21 | P9 | Inverter split | Indoor coil overheat protection in heating (selected models) | — |
| 21 | HP | Split (non-inverter) | Indoor coil overheat protection in heating (selected models) | — |
| 22 | PC | Inverter split | Outdoor temperature too low for cooling | — |
| 23 | PH | Inverter split | Outdoor temperature too high for heating (selected models) | — |
| 24 | EH | Inverter split | Humidity sensor fault (selected models) | — |
| 25 | EE | Inverter split | Indoor unit memory (EE) fault | — |
| 26 | E1 | Inverter split | Indoor fan fault | — |
| 26 | E5 / H6 | Split (non-inverter) | Indoor fan motor fault · full fix | — |
| 27 | E2 | Inverter split | Indoor fan zero-crossing detection abnormal | — |
| 28 | E3 | Inverter split | Indoor coil fault and coil sensor fault · full fix | — |
| 28 | E2 | Split (non-inverter) | Indoor coil temperature sensor fault | — |
| 29 | E4 | Inverter split | Indoor room temperature sensor fault | — |
| 29 | E1 | Split (non-inverter) | Indoor room temperature sensor fault | — |
| 30 | E5 | Inverter split | Refrigerant leak fault (selected models) · full fix | — |
| 31 | L1 | Inverter split | Drive bus voltage too high | — |
| 32 | L2 | Inverter split | Drive bus voltage too low | — |
| 33 | L3 | Inverter split | Drive phase current overload fault | — |
| 34 | L4 | Inverter split | Phase current sampling abnormal | — |
| 37 | EP | Inverter split | PM2.5 sensor fault (selected models) | — |
| 38 | EU | Inverter split | Voice module communication fault (selected models) | — |
Outdoor light flashes
| Flashes | Code | Model type | Meaning | What to do |
|---|---|---|---|---|
| 1 | E0 | Inverter split | Outdoor unit memory (EE) fault | — |
| 2 | E6 | Inverter split | Indoor and outdoor units not communicating · full fix | — |
| 4 | F1 | Inverter split | Compressor start abnormal or phase failure | — |
| 5 | F2 | Inverter split | Compressor out-of-step fault | — |
| 6 | F3 | Inverter split | IPM (inverter power module) fault | — |
| 7 | F4 | Inverter split | Compressor shell top fault or protection | — |
| 8 | F5 | Inverter split | Discharge temperature sensor fault | — |
| 9 | F6 | Inverter split | Suction temperature sensor fault (selected models) | — |
| 10 | F7 | Inverter split | Outdoor coil temperature sensor fault | — |
| 11 | F8 | Inverter split | Outdoor air temperature sensor fault | — |
| 12 | F9 | Inverter split | Outdoor DC fan fault (selected models) | — |
| 13 | P1 | Inverter split | Outdoor unit AC current protection | — |
| 14 | P2 | Inverter split | Compressor phase current protection | — |
| 15 | P3 | Inverter split | Outdoor unit supply voltage too high or too low · full fix | — |
| 16 | P4 | Inverter split | DC voltage too high or too low | — |
| 17 | P5 | Inverter split | IPM over-temperature protection | — |
| 18 | P6 | Inverter split | Discharge temperature overheat protection | — |
| 19 | P7 | Inverter split | Indoor coil anti-freeze protection in cooling | The AC is defrosting the indoor coil in cooling; the code shows for some time while frost is removed |
| 20 | P8 | Inverter split | Outdoor coil overheat protection in cooling | — |
| 21 | P9 | Inverter split | Indoor coil overheat protection in heating (selected models) | — |
| 22 | PC | Inverter split | Outdoor temperature too low for cooling | — |
| 23 | PH | Inverter split | Outdoor temperature too high for heating (selected models) | — |
| 24 | EH | Inverter split | Humidity sensor fault (selected models) | — |
| 25 | EE | Inverter split | Indoor unit memory (EE) fault | — |
| 26 | E1 | Inverter split | Indoor fan fault | — |
| 27 | E2 | Inverter split | Indoor fan zero-crossing detection abnormal | — |
| 28 | E3 | Inverter split | Indoor coil fault and coil sensor fault · full fix | — |
| 29 | E4 | Inverter split | Indoor room temperature sensor fault | — |
| 30 | E5 | Inverter split | Refrigerant leak fault (selected models) · full fix | — |
| 31 | L1 | Inverter split | Drive bus voltage too high | — |
| 32 | L2 | Inverter split | Drive bus voltage too low | — |
| 33 | L3 | Inverter split | Drive phase current overload fault | — |
| 34 | L4 | Inverter split | Phase current sampling abnormal | — |
| 39 | PE | Inverter split | Earth fault protection (newer manual) | — |
हिंदी में
डिस्प्ले पर कोड नहीं, सिर्फ़ बत्ती झपक रही है? बत्ती कितनी बार झपकती है, उसे गिनें। झपकने के बाद थोड़ा रुकती है, फिर दोबारा शुरू होती है। दो रुकावटों के बीच की गिनती ही आपका कोड है।
- ऊपर सही बत्ती चुनें और हर झपक पर बड़ा बटन दबाएं, या गिनती लिखें।
- एक ही गिनती के अलग मॉडल पर अलग मतलब हो सकते हैं। यूनिट के स्टिकर पर मॉडल देखें।
- मशीन को दीवार के स्विच से बंद करें। कोड और झपकने की गिनती लिख लें, फिर अधिकृत सर्विस को बुलाएं। यूनिट खुद न खोलें।
Questions people ask
How do I count Lloyd AC light blinks?
Watch the light for a full cycle: it flashes a number of times, pauses, then repeats. Count the flashes between two pauses. Count two or three cycles to be sure.
The same number of flashes shows two different faults. Which one is mine?
Lloyd uses different tables for different model types. Check the model name on the unit sticker and use the row for your model type.
Can I fix a blinking light fault myself?
Switch off the unit at the wall and note the code and the number of flashes. Lloyd's manual says to cut off the power supply before any work, not to repair the AC yourself, and to call a qualified technician. For E5 (refrigerant leak), switch off and call Lloyd service.
Sources
- Lloyd split AC owner's manual (Havells): Errors & Troubleshooting p.48, Defrost p.38, Malfunction analysis p.53
- Lloyd split AC user manual, new remote (Havells, 2025): Errors & Troubleshooting p.48
- Lloyd window AC manual (Havells): touch panel mode and fan speed display p.25, filter cleaning reminder CL, defrost dF and Errors & Troubleshooting p.26, Error Codes p.31
- Havells: manuals and documents (Lloyd)
Last checked: