हिंदी

Godrej AC Error Codes: E1, E6, F7, F9, H6, dF and More (Inverter and Fixed-Speed Split)

By FaultDecode · Checked against Godrej's official documents · Updated · How we check

25 Godrej codes on this page.

Your model:

Godrej split ACs show an error code on the indoor unit's display. Inverter and fixed-speed models use different tables, so the same code can mean different things: on an inverter model E1 is an indoor fan fault, while on a fixed-speed model E1 is a room temperature sensor error. Godrej says that if the inverter outdoor unit has a fault, the AC stops at once and the error appears on the indoor display. Every row here is from Godrej's owner's manuals (GSC 12ITC3-WUA, 18ITC3-WTA, 24ITC3-WUA) and the Godrej AC e-Catalogue 2025 on godrejenterprises.com. Godrej's catalogue notes that error codes may vary by model, so check your manual if your model is not listed.

Safety: Godrej's manuals list what each code means but give no repair steps. For fan, compressor, IPM, communication and sensor codes, switch the AC off and call Godrej authorised service. Do not open the indoor or outdoor unit yourself: it carries mains voltage and refrigerant.

How to see the code

  1. Read the code on the indoor unit's display.
  2. Check whether your AC is an inverter or a fixed-speed model (see the model name, box or manual), because the two use different tables.
  3. Find the code in Godrej's list, in the rows for your model type (inverter or fixed-speed).

How to check the error code on other AC brands

Godrej AC error code list

CodeModel typeMeaningWhat to do
EE Inverter split Indoor unit EE fault (Godrej gives no more detail) Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E1 Inverter split Indoor fan fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E2 Inverter split Indoor fan zero-crossing detection abnormal Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E3 Inverter split Indoor coil fault and sensor fault (18ITC3 manual: indoor coil sensor fault) Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E4 Inverter split Indoor ambient (room) temperature sensor fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E0 Inverter split Outdoor unit EE fault (Godrej gives no more detail) Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E6 Inverter split Indoor and outdoor unit communication fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E8 Inverter split Outdoor communication fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F1 Inverter split Compressor starting abnormal (phase failure, reverse) Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F2 Inverter split Compressor out-of-step fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F3 Inverter split IPM module fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F4 Inverter split Compressor shell top fault or protection Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F5 Inverter split Discharge temperature sensor fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F6 Inverter split Suction temperature sensor fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F7 Inverter split Outdoor coil temperature sensor fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F8 Inverter split Outdoor ambient temperature sensor fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
F9 Inverter split Outdoor DC fan fault Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
H6/E5 Fixed-speed split Indoor unit fan motor protection: the compressor and fan turn off immediately Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
dF Fixed-speed split Frost protection Godrej lists dF as frost protection and gives no steps. If dF keeps coming, switch the AC off and call Godrej authorised service.
E1 Fixed-speed split Room temperature sensor error (sensor short or open). The display shows E1 and the set temperature by turns. Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E2 Fixed-speed split Evaporator (indoor coil) sensor error (sensor short or open). The display shows E2 and the set temperature by turns. Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
U8 Fixed-speed split (selected models) Zero cross detection Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
E3 Fixed-speed split (selected models) Outdoor coil (condenser) sensor error, in heat mode. The display shows E3 and the set temperature by turns. Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.
HF Fixed-speed split (selected models) Outdoor unit frost protection (in heat mode) Godrej lists HF as outdoor unit frost protection in heat mode and gives no steps. If it keeps coming, switch the AC off and call Godrej authorised service.
HP Fixed-speed split (selected models) Indoor coil overheat protection (in heat mode) Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.

No code, but a problem?

Good to know

हिंदी में

Godrej स्प्लिट एसी में खराबी होने पर इनडोर यूनिट के डिस्प्ले पर कोड आता है। इन्वर्टर और फ़िक्स्ड-स्पीड मॉडल के कोड अलग हैं: इन्वर्टर में E1 = इनडोर पंखा खराब, फ़िक्स्ड-स्पीड में E1 = कमरे का तापमान सेंसर खराब। E6 = इनडोर और आउटडोर यूनिट में बात नहीं हो रही।

  1. डिस्प्ले पर कोड पढ़ें।
  2. देखें आपका एसी इन्वर्टर है या फ़िक्स्ड-स्पीड, फिर सही टेबल में कोड देखें।
  3. पंखा, कंप्रेसर, IPM, सेंसर या कम्युनिकेशन वाला कोड हो तो एसी बंद करें और Godrej सर्विस बुलाएं।
  4. एसी की इनडोर या आउटडोर यूनिट खुद न खोलें।

Questions people ask

What does E1 mean on a Godrej AC?

On Godrej inverter split ACs, E1 is an indoor fan fault. On fixed-speed models, E1 is a room temperature sensor error (sensor short or open), and the display shows E1 and the set temperature by turns. In both cases switch off and call Godrej service.

What does E6 mean on a Godrej AC?

On Godrej inverter ACs, E6 is a communication fault between the indoor and outdoor units. Switch the AC off and call Godrej service.

What does H6 mean on a Godrej AC?

On Godrej fixed-speed split ACs, H6 (or E5) is indoor fan motor protection: the compressor and fan turn off immediately. Switch off and call Godrej service.

What do F7 and F9 mean on a Godrej AC?

On Godrej inverter ACs, F7 is an outdoor coil temperature sensor fault (the catalogue says a fault with the temperature sensor on the outdoor unit) and F9 is an outdoor DC fan fault. Call Godrej service.

Sources

Last checked:

↑