Quick answer
LO on an IFB top load washing machine (Aqua TL-REGS, REWS, RESS, RPSS, R1 and R2 series) means the input voltage is too low. IFB says the machine will start automatically after the voltage increases to a safe level. If it keeps happening, get an electrician to check your supply.
What LO means on an IFB top load
It does not mean the machine is faulty.
What you should do
Wait for the machine to start again by itself. If LO appears often, get the supply and wiring checked by an electrician.
At what voltage does an IFB top load stop?
IFB's code table does not print a voltage next to Lo. The top load manuals instead describe High-Low Voltage Protection: a microcontroller watches the supply and stops the program if the voltage goes below 165 ± 10 V (or above 270 ± 10 V). The program resumes once the voltage is back in a safe range. This is in the TL-REGS/REWS/RESS manual (p.48), the TL-RPSS/R2 manual (p.51) and the TL650 to TL801 manual (p.54). IFB front loads use a lower cut-off of 150 ± 10 V.
Does the wash start again from the beginning?
The same manuals also list Program Memory Backup: after a power cut, the program remembers where to pick up when power returns.
The electrical point IFB asks for
The TL-REGS/REWS/RESS manual (p.27) says a 16 A, 3-pin, 220–240 V AC, 50 Hz point with a 16 A MCB (or automatic short circuit protection device) within 1 m of the machine is mandatory, with proper earthing and a firm fit between socket and plug. It also says not to use an extension cable (p.15). Show this to the electrician who checks your wiring.
Other IFB codes for low voltage
Some IFB top load series, such as TL-RES, TL650 to TL801 and TL100/TL900, show ACL instead of LO. IFB front load machines show the same problem as Lo 175 or L175, depending on the model.
When to call IFB
If LO keeps appearing after the wiring is checked, call IFB Care.
Safety: Do not open the machine or its plug. Voltage problems are for an electrician.
Common causes
- Mains supply voltage too low for the machine
Fix it step by step
0 of 3 done
- Wait. The machine starts automatically once the voltage increases to a safe level.
- If LO appears often, get the supply and wiring checked by an electrician.
- When the electrician checks the supply, ask them to confirm the point IFB asks for: a 16 A, 3-pin, earthed socket with a 16 A MCB within 1 m of the machine, and no extension cable.
Still showing Lo?
- IFB Care: 080 695 45678 or 08045845678 (printed in the TL-REGS/REWS/RESS manual, p.68), or book service in the My IFB App.
हिंदी में
IFB टॉप लोड मशीन में LO का मतलब है मिलने वाला वोल्टेज बहुत कम है। यह सुरक्षा है, खराबी नहीं।
- इंतज़ार करें। वोल्टेज ठीक होते ही मशीन खुद चालू हो जाएगी।
- LO बार-बार आए तो इलेक्ट्रीशियन से घर की बिजली सप्लाई और वायरिंग चेक कराएं।
- मशीन के लिए 16 एम्प का 3-पिन, अर्थिंग वाला सॉकेट और मशीन से 1 मीटर के अंदर 16 एम्प MCB होना चाहिए। एक्सटेंशन बोर्ड न लगाएं।
Questions people ask
Does LO mean my machine is faulty?
No. IFB lists LO as input voltage too low. The machine waits and starts again by itself.
Is the code the same on every IFB top load?
No. Some IFB top load series, such as TL-RES, TL650 to TL801 and TL100/TL900, show ACL for input voltage low. Check your manual.
At what voltage does an IFB washing machine stop?
IFB does not print a voltage next to Lo. Its top load manuals say the High-Low Voltage Protection stops the program below 165 ± 10 V and resumes it once the voltage is safe again. The manual does not say that Lo is shown at exactly this voltage.
Can I use an extension board for my IFB washing machine?
No. IFB's manual says to avoid extension cables for safety and to use a 16 A, 3-pin earthed point with a 16 A MCB within 1 m of the machine.
Did this fix your problem? क्या इससे मदद मिली?
What went wrong?
Thanks. This helps us fix our guides. धन्यवाद!
Sources
- IFB user manual: TL-REGS / REWS / RESS Aqua top load (pp.15, 27, 48, 68)
- IFB user manual: TL-RPSS / R2 series Aqua top load (p.51)
- IFB user manual: Executive ZVN / ZMN / ZBN front load
- IFB support: TL-RES top load, error codes
- IFB user manual: TL650 to TL801 top load (p.54)
Last checked: