हिंदी

L175 Error in IFB Washing Machine: Voltage Too Low, Restarts by Itself

Quick answer

L175 on an IFB front load washing machine means the input voltage is too low. It is a protection, not a breakdown: the machine restarts by itself when the voltage comes up. If you see L175 often, IFB advises having an electrician check your electrical system.

What L175 means on an IFB washing machine

IFB's Executive front load manual shows the same message as Lo 180.

What you should do

Wait for the voltage to come back up.

At what voltage does an IFB front load stop?

IFB's code table does not print a voltage next to L175. The front load manuals instead describe High-Low Voltage Protection: a microcontroller watches the supply and stops the program if the voltage goes below 150 ± 10 V (or above 270 ± 10 V). The program resumes once the voltage is back in a safe range. This is in the Elena, Elite and Senator manual (p.51), the Executive manual (p.59) and the Diva Aqua manual (p.39).

Does the wash start again from the beginning?

The Elena, Elite and Senator manual (p.51) and the Executive manual (p.59) also list Program Memory Backup: after a power cut, the program remembers where to pick up when power returns.

The electrical point IFB asks for

The Elena, Elite and Senator manual (p.25) says a 16 A, 3-pin, 220–240 V AC, 50 Hz point with a 16 A MCB within 1 m of the machine is mandatory, with proper earthing and a firm fit between socket and plug. It also says not to use an extension cable (p.15). The rated supply is 220–240 V single phase, 50 Hz (p.78). Show this to the electrician who checks your wiring.

Top load versions of this code

Many IFB top load machines show ACL for low voltage, while the Aqua TL-REGS, REWS, RESS, RPSS, R1 and R2 series show Lo.

When to call IFB

If L175 happens often even after the wiring is checked, call IFB Care.

Safety: Do not open the machine or its plug. Voltage problems are for an electrician.

Common causes

  • Mains supply voltage too low for the machine

Fix it step by step

  1. Wait. The machine restarts by itself when the voltage comes up.
  2. If L175 appears often, get the wiring and supply checked by an electrician.
  3. When the electrician checks the supply, ask them to confirm the point IFB asks for: a 16 A, 3-pin, earthed socket with a 16 A MCB within 1 m of the machine, and no extension cable.

Still showing L175?

  • IFB Care: 080 695 45678 or 08045845678 (printed in the Elena, Elite and Senator manual, p.77), or book service in the My IFB App.

हिंदी में

L175 का मतलब है IFB फ्रंट लोड मशीन को मिलने वाला वोल्टेज बहुत कम है। यह सुरक्षा के लिए है, खराबी नहीं।

  1. इंतज़ार करें। वोल्टेज ठीक होते ही मशीन खुद फिर चालू हो जाती है।
  2. L175 बार-बार आए तो इलेक्ट्रीशियन से घर की वायरिंग चेक कराएं।
  3. मशीन के लिए 16 एम्प का 3-पिन, अर्थिंग वाला सॉकेट और मशीन से 1 मीटर के अंदर 16 एम्प MCB होना चाहिए। एक्सटेंशन बोर्ड न लगाएं।

Questions people ask

My machine shows Lo 180. Is it the same?

Yes. IFB's Executive front load manual lists Lo 180 as input voltage low.

At what voltage does an IFB washing machine stop?

IFB does not print a voltage next to L175. Its front load manuals say the High-Low Voltage Protection stops the program below 150 ± 10 V and resumes it once the voltage is safe again. The manual does not say that L175 is shown at exactly this voltage.

Can I use an extension board for my IFB washing machine?

No. IFB's manual says to avoid extension cables for safety and to use a 16 A, 3-pin earthed point with a 16 A MCB within 1 m of the machine.

Sources

Last checked:

↑