Geyser reset button: what it does and when to call service
Quick answer
On Racold and Havells geysers, the part that needs a reset after the geyser stops heating is the thermal cut-out: a non-self-resetting safety device that cuts the power on a fault or when the water gets too hot (Havells gives 93 °C ± 5 °C or 95 °C ± 5 °C depending on model). It is an internal part. Racold says contact only authorised service personnel when it operates, and Havells says do not start the unit by resetting the thermal cut-out if both lamps do not glow. Some digital models have a separate user reset: Racold Omnis Slim shows Er plus a code, and for E60, E61 and E63 the manual says reset by disconnecting and reconnecting the power cable; Havells Adonia i resets by holding + and - for 5 seconds, and Havells Monza Slim i by switching the power off and on 5 or more times. A shock safe plug or ELCB also has a reset button after you press Test.
Safety: Do not open the geyser to press the thermal cut-out yourself. Racold says contact authorised service personnel when it operates, and Havells says safety devices such as the thermostat and thermal cut-out are factory set: do not tamper with them. A cut-out that trips points to a fault (Racold: a fault or water above the preset limit; Havells: thermostat failure), and Racold lists dry heating as one cause, so the geyser needs to be checked. Havells says if you notice any abnormal operation, immediately switch off the main power supply and contact the nearest customer care centre.
Jump to: Thermal cut-outRacold Omnis SlimRacold settingsHavells resetShock safe plugCall serviceRelated codes
1. The 'reset button' inside the geyser: thermal cut-out
- What it is (Racold): A non-self-resetting thermal cut-out that disconnects the electrical supply if a fault occurs or the water temperature exceeds the preset limit (Racold Pronto: set to operate below 96 °C). Racold says contact only authorised service personnel in such an event.
- What it is (Havells): A non-self-resetting thermal cut-out is a safety device. If the thermostat fails (Adonia i, Monza Slim i, Magnatron) or the NTC sensor fails (Orizzonte), it cuts the power at 93 °C ± 5 °C (Adonia i, Monza Slim i) or 95 °C ± 5 °C (Orizzonte, Magnatron). Havells Adonia i and Monza Slim i say it has to be manually reset before the heater can work again.
- Why it trips (Racold): Racold's troubleshooting table lists 'cut out operated due to dry heating' when the unit is not working, and 'cut out trip' when there is no hot water output. The action given is 'Reset Cut out'. Racold's safety-device section says to contact only authorised service personnel when the cut-out operates (CDR, Pronto).
- How to tell (Racold): On Omnis Slim, if both the red and blue lights are off, the thermal cut-out has been activated: contact the service personnel. On Pronto, the blue lamp that is on in normal use turns off when the cut-out is activated.
- Do not reset it to restart (Havells): If both lamps do not glow, do not start the unit by resetting the thermal cut-out; contact the nearest customer care centre instead (Adonia i, Monza Slim i). Magnatron gives the same warning, and Orizzonte says the same when the power icon does not glow.
- Racold Omnis Slim wiring note: To avoid a hazard due to inadvertent resetting of the thermal cut-out, the geyser must not be supplied through an external switching device such as a timer, or a circuit that is regularly switched on and off by the utility.
From: Racold CDR / Buono Pro manual; Racold Omnis Slim manual; Racold Pronto manual; Havells Adonia i manual; Havells Monza Slim i manual; Havells Orizzonte manual; Havells Magnatron manual
2. Racold Omnis Slim: error code reset
When there is an error, the Omnis Slim display shows 'Er' and the error code in turn, and all LEDs blink. The user column of Racold's table says:
- E01 (HMI memory error), E21 (overheating), E22 (thermostat error): Perform reset. If the error is still present, call technical assistance.
- E25 (dry heating): Check that there is water in the geyser and perform reset. If the error is still present, call technical assistance.
- E60 (Wi-Fi error), E61 (HMI PCB error), E63 (touch error): Perform reset by disconnecting and reconnecting the power supply cable. If the error is still present, call technical assistance.
- E20 (temperature sensor), E62 (HMI memory data): If the error is present, call technical assistance.
Racold's service column also says to wait until the water is below 75 °C before resetting E21, E22 and E25.
From: Racold Omnis Slim manual
3. Racold Omnis Slim: other resets
- Eco learning reset: Eco learns your hot water use over the first week. To clear it and start learning again, press SET and Auto Power Off together for 5 seconds (Wi-Fi version: SET and WIFI). The display shows E- for a moment to confirm.
- After Auto Power Off: Press On-Off to turn the geyser on again, or switch the main wall switch OFF and ON again for at least 3 seconds; it turns on with heating on and the last Auto Power Off timer.
From: Racold Omnis Slim manual
4. Havells digital geysers: reset steps
- Havells Adonia i: Press and hold the + and - buttons together for 5 seconds. Fy appears on the display, then the default temperature 65 blinks 3 times to confirm the reset. The factory-set temperature is 65 °C. (The manual does not say this resets the thermal cut-out.)
- Havells Monza Slim i: Switch the power on and off 5 or more times in a row, with less than 5 seconds between each; each turn-off must come within 5 seconds of turn-on. On a successful reset both LEDs turn off and on. The factory-set temperature is 75 °C. (The manual does not say this resets the thermal cut-out.)
5. Test and reset button on the plug (shock safe plug / ELCB)
- Havells Adonia i, Orizzonte (shock safe plug), Magnatron (ELCB / shock safe plug): It cuts the power at once if there is current leakage. To check it, press the Testing button: if it cuts the power, it works. After testing, press the reset button to restore normal working. Havells says to use the test button at least once a month.
From: Havells Adonia i manual; Havells Orizzonte manual; Havells Magnatron manual
6. When to call service
- Thermal cut-out has operated: Racold: contact only authorised service personnel. Havells (Adonia i, Monza Slim i): if both lamps do not glow, contact customer care rather than resetting the cut-out.
- Error code returns after reset (Racold Omnis Slim): Call technical assistance.
- Safety devices: Havells says the safety valve, thermostat and thermal cut-out are preset in the factory and sensitive: do not tamper with them, as this could be hazardous.
From: Racold CDR / Buono Pro manual; Racold Omnis Slim manual; Havells Monza Slim i manual
Havells geyser codes
- Havells E2 (Adonia i, Monza Slim i): Water temperature reached 90 °C
- Havells E5 (Adonia i, Monza Slim i): Dry heating detected: heating cuts off when the geyser senses a high temperature rise rate without water
- Havells E05 (Magnatron (15 L, 25 L)): Water temperature above 90 °C
- Havells E12 (Magnatron (15 L, 25 L)): No water inside the tank
हिंदी में
गीज़र के अंदर का 'रीसेट बटन' असल में थर्मल कट-आउट है: पानी बहुत गर्म होने पर यह बिजली काट देता है और अपने आप रीसेट नहीं होता। Racold कहता है ऐसा होने पर सिर्फ़ अधिकृत सर्विस वाले को बुलाएँ, और Havells कहता है दोनों लैंप न जलें तो कट-आउट रीसेट करके गीज़र चालू न करें। कुछ डिजिटल मॉडल में अलग रीसेट होता है।
- गीज़र खोलकर कट-आउट खुद न दबाएँ; सर्विस बुलाएँ (Racold, Havells)।
- Racold Omnis Slim में Er और कोड दिखे: E60, E61, E63 में पावर केबल निकालकर फिर लगाएँ; E25 में पहले पानी है या नहीं देखें। कोड फिर आए तो सर्विस बुलाएँ।
- Havells Adonia i: + और - बटन 5 सेकंड साथ दबाएँ; Fy दिखेगा और 65 तीन बार ब्लिंक करेगा।
- Havells Monza Slim i: बिजली 5 या ज़्यादा बार चालू-बंद करें, हर बार 5 सेकंड के अंदर; दोनों LED बंद होकर फिर जलेंगी।
- शॉक सेफ प्लग / ELCB: Testing बटन दबाएँ, बिजली कटे तो ठीक है, फिर reset बटन दबाएँ।
Questions people ask
Where is the reset button on a Racold geyser?
On Racold geysers the reset is the thermal cut-out, a non-self-resetting safety device. Racold says contact only authorised service personnel when it operates. On the Omnis Slim, error codes E60, E61 and E63 are reset by disconnecting and reconnecting the power cable.
Why did my geyser's thermal cut-out trip?
It cuts the power on a fault or when the water temperature goes past its limit, for example if the thermostat fails (Havells). Racold's troubleshooting table lists dry heating as a cause. Have it checked by service.
How do I reset a Havells digital geyser?
Adonia i: hold + and - together for 5 seconds until Fy shows and 65 blinks 3 times. Monza Slim i: switch the power on and off 5 or more times, each within 5 seconds, until both LEDs turn off and on.
What is the test and reset button on the geyser plug?
On Havells models with a shock safe plug or ELCB, Test checks that it cuts the power on current leakage; press reset afterwards to restore power.
Sources
- Racold CDR and Buono Pro electric storage water heater instruction manual (24-04-2026): thermal cutout p.4, troubleshooting guide p.8
- Racold Omnis Slim water heater manual (24-04-2025): thermal cut-out p.4, troubleshooting guide p.7, Eco function p.11, Auto Power Off p.12, error codes p.13, precautions p.14
- Racold Pronto instant water heater manual (24-04-2026): thermal cut-out and blue lamp p.4, troubleshooting guide p.9
- Havells Adonia i water heater user manual: thermal cutout and shock safe plug p.8, test button monthly p.11, reset p.29, do's and don'ts p.31
- Havells Monza Slim i water heater user manual: thermal cutout p.8, reset p.29, do's and don'ts p.31
- Havells Orizzonte water heater user manual: thermal cutout p.7, shock safe plug p.8, test button p.11, do's and don'ts p.17
- Havells Magnatron water heater user manual: thermal cutout p.8, ELCB p.9, test button p.12, do's and don'ts p.18