Havells gives error code tables only in the manuals for Adonia i, Monza Slim i, Orizzonte and Magnatron. The other Havells geyser manuals we read (for example Monza DX, Puro DX, Puro Plus, Fabia, Otto, Opal and Adonia Digital/Remote) list no error codes. The codes are not the same on every model: on Adonia i and Monza Slim i, E2 means the water reached 90 °C, while on Orizzonte E2 means overheating or a sensor short circuit, and on the induction-heated Magnatron the codes are E01 to E08 and E12. Every row here is from Havells' own user manuals on havells.com. Check your model name on the rating label, then read the row for that model.

Safety: A geyser mixes water and mains electricity. For any code about overheating, the temperature sensor (NTC), the circuit board, dry heating or no water, switch the geyser off at the wall and call Havells authorised service. Havells' manual says the thermal cutout and other safety devices are set at the factory and must not be tampered with, and that if the lamps (on Orizzonte, the power icon) do not glow you should not reset the thermal cutout yourself but contact customer care. Never switch a geyser on without water in it.

How to see the code

  1. Look at the geyser's front: digital models (Adonia i, Orizzonte, Magnatron) show the code on the temperature display, for example E 2.
  2. On Monza Slim i, which has LEDs instead of a number display, the Power LED keeps blinking red and the code shows in the Havells Sync mobile app.
  3. Note your model name from the rating label, because the same code means different things on different models.
  4. Match the code and model in the Havells geyser error code list.

Light blinking? See what each Havells light means and what to do first.

What the Havells lights mean

Power LED (red/blue) Keeps blinking red

An error: the code (E 2 to E 5) shows in the Havells Sync app.

What to do: Open the app to read the code, then look it up in the Havells geyser error code list for your model.

Monza Slim i

Power LED (red/blue) Blue, steady

Normal: water is heating.

What to do: Nothing to do.

Monza Slim i

Power LED (red/blue) Red, steady

Normal: water is heated to the set temperature.

What to do: Nothing to do.

Monza Slim i

Connectivity LED (red/green) Red, blinking

The geyser is not connected to the Wi-Fi router.

What to do: Set up Wi-Fi in the Havells Sync app.

Monza Slim i

Connectivity LED (red/green) Red, steady

Connected to the router but no internet access.

What to do: Check your router's internet connection.

Monza Slim i

Connectivity LED (red/green) Green, steady

Connected to the router with internet access.

What to do: Nothing to do.

Monza Slim i

Display dot Blinks once per second

The geyser is not connected to the home router.

What to do: Set up Wi-Fi in the Havells Sync app. The dot goes off when connected.

Adonia i

LEDs Amber

Normal: water is heated to the set temperature (blue or any colour except amber means it is heating).

What to do: Nothing to do.

Adonia i

Havells geyser error code list

CodeModel typeMeaningWhat to do
E2 (shown as E 2) Adonia i, Monza Slim i Water temperature reached 90 °C Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E3 (shown as E 3) Adonia i, Monza Slim i NTC temperature sensor open circuit (no voltage across the sensor) Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E4 (shown as E 4) Adonia i, Monza Slim i NTC temperature sensor short circuited (maximum voltage across the sensor, nearly 5 V) Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E5 (shown as E 5) Adonia i, Monza Slim i Dry heating detected: heating cuts off when the geyser senses a high temperature rise rate without water Switch off at the wall. Make sure the inlet valve is open and the tank is full of water, then call Havells service. Never switch the geyser on without water: Havells says it damages the heating element.
E2 Orizzonte (15 L, 25 L) Overheating or NTC temperature sensor short circuit Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E3 Orizzonte (15 L, 25 L) NTC temperature sensor open circuit Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E01 Magnatron (15 L, 25 L) Heating surface not detected by the circuit Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E02 Magnatron (15 L, 25 L) Coil installation is abnormal Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E03 Magnatron (15 L, 25 L) Input voltage is outside the range of 180 V to 265 V Switch the geyser off at the wall. Havells' table says the input voltage is outside 180 V to 265 V. If the code stays or keeps coming back, call Havells service. Do not open the geyser.
E04 Magnatron (15 L, 25 L) Water temperature sensor problem Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E05 Magnatron (15 L, 25 L) Water temperature above 90 °C Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E06 Magnatron (15 L, 25 L) Open or short circuit in the electronic circuit Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E07 Magnatron (15 L, 25 L) Temperature is too high in the electronic circuit Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E08 Magnatron (15 L, 25 L) Communication between the power PCB and the display PCB is abnormal Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.
E12 Magnatron (15 L, 25 L) No water inside the tank Switch off at the wall. Havells' manual says to keep the inlet valve open and, before switching on again, to make sure the drain plug lever on the safety valve is reset and screwed and to fill the geyser until clean water flows from the hot tap. If the code stays, call Havells service. Do not open the geyser.

No code, but a problem?

Good to know

हिंदी में

Havells के मैनुअल में एरर कोड सिर्फ़ Adonia i, Monza Slim i, Orizzonte और Magnatron के लिए दिए गए हैं। Adonia i और Monza Slim i में E 2 = पानी 90 °C तक गर्म, E 3 और E 4 = तापमान सेंसर (NTC) खराब, E 5 = बिना पानी के गर्म होना। Orizzonte और Magnatron के कोड अलग हैं, नीचे टेबल देखें।

  1. डिस्प्ले पर कोड पढ़ें। Monza Slim i में Power LED लगातार लाल झपके तो कोड Havells Sync ऐप में दिखेगा।
  2. रेटिंग लेबल पर मॉडल का नाम देखें, क्योंकि हर मॉडल में कोड का मतलब अलग है।
  3. ज़्यादा गर्म, सेंसर, सर्किट, बिना पानी या पानी नहीं वाला कोड हो तो गीज़र को स्विच से बंद करें और Havells सर्विस बुलाएं।
  4. गीज़र को कभी बिना पानी के चालू न करें। इनलेट वाल्व हमेशा खुला रखें।
  5. थर्मल कटआउट या दूसरे सेफ्टी पार्ट खुद रीसेट न करें, गीज़र न खोलें।

Questions people ask

What does E2 mean on a Havells geyser?

On Adonia i and Monza Slim i, E 2 means the water temperature reached 90 °C. On Orizzonte, E2 means overheating or a short circuit in the NTC temperature sensor. On Magnatron the code is E02, which means the coil installation is abnormal. In every case, switch the geyser off at the wall and call Havells service.

What does E5 mean on a Havells geyser?

On Adonia i and Monza Slim i, E 5 means dry heating: the geyser sensed the temperature rising too fast, as happens without water, and cut the heating. Switch off at the wall, make sure the inlet valve is open and the tank is full, and call Havells service. Do not run a geyser without water: Havells says it damages the heating element.

My Havells geyser shows E3 or E4. What is it?

On Adonia i and Monza Slim i, E 3 means the NTC temperature sensor is open circuit and E 4 means it is short circuited. On Orizzonte, E3 means NTC open circuit. A sensor fault needs a technician: switch off and call Havells service.

Why is the red light blinking on my Havells Monza Slim i?

On Monza Slim i, a Power LED that keeps blinking red means an error; the code (E 2 to E 5) shows in the Havells Sync app. A steady red Power LED is normal: the water has reached the set temperature. A blinking red Connectivity LED only means the geyser is not connected to Wi-Fi.

My Havells geyser has no digital display. Does it have error codes?

Havells' manuals give error codes only for Adonia i, Monza Slim i, Orizzonte and Magnatron. The manuals for models with a temperature knob (for example Puro DX, Puro Plus, Monza DX, Fabia) list no codes. Their LED only shows heating (blue) or ready (amber, on models that have it). If the geyser will not heat, switch it off at the wall and call Havells service. Do not reset the thermal cutout yourself.