OPERATION lamp (green) Blinks and the AC stops
Operation stopped suddenly. Daikin says to check for dirty air filters and anything blocking the air inlet or outlet of the indoor or outdoor unit.
What to do: Clean the air filters. Stop the AC, switch off the circuit breaker and remove any obstruction, then restart with the remote. If the lamp still blinks, read the error code (hold CANCEL for 5 seconds) and consult your Daikin service centre. If it stops blinking, there is no malfunction. (FTHT manual: if the lamp still flashes, call the service shop where you bought the AC.)
Split AC: MTKM/FTKU XV16, FTKL XV16, FTHT XV16, FTL UV16 (non-inverter)
OPERATION (green) and TIMER (orange) lamps Blink alternately for 5 minutes, display shows FC
Filter clean reminder: it is time to clean the air filters. Not a fault.
What to do: Clean the filters, then reset the filter clean indicator as shown in your manual. Until reset, FC and the blinking come back for 5 minutes each time the AC is switched on.
Split AC: MTKM/FTKU XV16, FTKL XV16, FTHT XV16
OPERATION (green) and TIMER (orange) lamps Blink together
DEW CLEAN is running. Not a fault.
What to do: Nothing to fix. Daikin says the lamps blink together during DEW CLEAN operation.
Split AC: MTKM/FTKU XV16, FTKL XV16, FTHT XV16, FTKF XV16
OPERATION lamp (green) Stays on, but the AC stopped
Voltage protection: the AC may stop after a sudden large voltage change (the XV16 manuals give a protection range of 130 V to 285 V).
What to do: Wait. Daikin says it resumes by itself in about 3 minutes.
Split AC: MTKM/FTKU XV16, FTKL XV16, FTHT XV16, FTL UV16
TIMER lamp (orange) Lit (steady)
A timer is set. Not a fault.
What to do: Nothing to fix. The TIMER lamp lights orange while a timer is set and goes off when it ends.
Split AC: MTKM/FTKU XV16, FTKL XV16, FTL UV16