   "appliance": "ac",
   "brand": "Daikin",
   "code": "00",
   "also_shown_as": "",
   "model": "",
   "meaning": "Normal, no fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-00"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "UA",
   "also_shown_as": "",
   "model": "System",
   "meaning": "Indoor and outdoor units are the wrong combination",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-ua"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "U0",
   "also_shown_as": "",
   "model": "System",
   "meaning": "Refrigerant shortage",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-u0"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "U2",
   "also_shown_as": "",
   "model": "System",
   "meaning": "Voltage drop or main circuit overvoltage",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-u2"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "U4",
   "also_shown_as": "",
   "model": "System",
   "meaning": "Communication failure between indoor and outdoor units",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-u4"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "A1",
   "also_shown_as": "",
   "model": "Indoor",
   "meaning": "Indoor circuit board (PCB) fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-a1"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "A5",
   "also_shown_as": "",
   "model": "Indoor",
   "meaning": "Freeze-up protection",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-a5"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "A6",
   "also_shown_as": "",
   "model": "Indoor",
   "meaning": "Indoor fan motor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-a6"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "C4",
   "also_shown_as": "",
   "model": "Indoor",
   "meaning": "Heat exchanger temperature sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-c4"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "C9",
   "also_shown_as": "",
   "model": "Indoor",
   "meaning": "Suction air temperature sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-c9"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "E1",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Outdoor circuit board fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-e1"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "E5",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Overload protection started",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-e5"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "E6",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Compressor failed to start",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-e6"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "E7",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Outdoor DC fan motor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-e7"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "E8",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Input overcurrent",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-e8"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "F3",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Discharge pipe temperature too high",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-f3"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "F6",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "High pressure control (cooling)",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-f6"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "H0",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-h0"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "H6",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Stopped by a faulty position detection sensor",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-h6"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "H8",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "DC current sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-h8"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "H9",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Suction air temperature sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-h9"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "J3",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Discharge pipe temperature sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-j3"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "J6",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Heat exchanger temperature sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-j6"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "L3",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Electrical parts overheating",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-l3"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "L4",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "High temperature at the inverter heatsink",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-l4"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "L5",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Output overcurrent",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-l5"
  },
  {
   "appliance": "ac",
   "brand": "Daikin",
   "code": "P4",
   "also_shown_as": "",
   "model": "Outdoor",
   "meaning": "Inverter heatsink temperature sensor fault",
   "what_to_do": "",
   "source": "https://daikinindia.com/error-codes https://daikinindia.com/product-services/product-services/troubleshooting https://www.daikin.com.my/service/error-codes/ https://daikinindia.com/product-services/product-services/troubleshooting https://manuals.daikinindia.com/uploads/manuals/1790665668_1790657912_3P785322-9RInverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1791269370_1783583573_1776416200_1774265404_OPERATIONALMANUAL%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1790587882_1775706245_HT71MANUALneedtoupdate%281%29%281%29.pdf https://manuals.daikinindia.com/uploads/manuals/1757489801_3P719813-10SNon-Inverteroperation%26InstallationManual.pdf https://manuals.daikinindia.com/uploads/manuals/1782800455_3P785322-16.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/daikin/#code-p4"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "door",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Door not closed or locked",
   "what_to_do": "Open and close the door firmly.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-door"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "dLEr",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Door stuck or jammed",
   "what_to_do": "Switch off, wait 2 minutes, do not force the door. If it stays, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-dler"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "tAP",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Tap off, low water pressure, blocked inlet sieve or bent hose",
   "what_to_do": "Open the tap (the machine restarts by itself), clean the inlet sieve, replace a bent hose.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-tap"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "dPEr",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Water not drained",
   "what_to_do": "Press Start/Pause to drain again. If the filter is blocked, switch off, drain and clean it. Straighten the drain hose.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-dper"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "E1",
   "also_shown_as": "",
   "model": "Front load (Elena SBS)",
   "meaning": "Cloth trapped between drum and door",
   "what_to_do": "Switch off, wait 2 minutes, run Drain, rearrange the clothes and restart. If it repeats, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-e1"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "E2, E3",
   "also_shown_as": "",
   "model": "Front load (Elena SBS)",
   "meaning": "Not explained by IFB; IFB gives the same steps as E1",
   "what_to_do": "Switch off, wait 2 minutes, run Drain, rearrange the clothes and restart. If it repeats, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-e2-e3"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "tACO trC",
   "also_shown_as": "",
   "model": "Front load (Elite, Elena ZWS, Senator)",
   "meaning": "Cloth trapped between drum and door",
   "what_to_do": "Switch off, run Drain, rearrange the clothes and restart. If it repeats, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-taco-trc"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "H260",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Input voltage too high",
   "what_to_do": "The machine restarts by itself when voltage comes down. If it happens often, get the wiring checked by an electrician.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-h260"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "L175",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Input voltage too low",
   "what_to_do": "The machine restarts by itself when voltage comes up. If it happens often, get the wiring checked by an electrician.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-l175"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "unbL",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Load unbalanced",
   "what_to_do": "Add 1 or 2 similar items and spread the load.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-unbl"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "HEAt",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Water above 60°C at the start of a programme",
   "what_to_do": "Wait for the water to cool, then start or drain. If it stays, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-heat"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "Conn",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Not explained by IFB",
   "what_to_do": "Switch off, wait 2 seconds, restart. If it repeats, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-conn"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "OFEr Pr5",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Not explained by IFB",
   "what_to_do": "Switch off, wait 2 seconds, restart. If it repeats, close the tap and call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-ofer-pr5"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "rinS HOLd",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Not an error: the machine is holding the rinse water",
   "what_to_do": "Press Start/Pause or choose Drain.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-rins-hold"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "dLAY",
   "also_shown_as": "",
   "model": "Front load",
   "meaning": "Not an error: delay start is on",
   "what_to_do": "",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-dlay"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "1 flash",
   "also_shown_as": "",
   "model": "Front load, LED (Diva Aqua)",
   "meaning": "Door not closed or locked, or door not unlocking at the end of the program",
   "what_to_do": "Close the door firmly. If it will not unlock, switch off, wait 2 minutes and try; do not force it. Call IFB Care if it stays.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-1-flash"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "2 flashes",
   "also_shown_as": "",
   "model": "Front load, LED (Diva Aqua)",
   "meaning": "Tap off or low water pressure",
   "what_to_do": "Open the tap or press Start/Pause twice to refill. Check the hose and sieve.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-2-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "3 flashes",
   "also_shown_as": "",
   "model": "Front load, LED (Diva Aqua)",
   "meaning": "Water not drained",
   "what_to_do": "Drain again, clean the filter, check the drain hose.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-3-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "4 flashes",
   "also_shown_as": "",
   "model": "Front load, LED (Diva Aqua)",
   "meaning": "Unbalanced load",
   "what_to_do": "Add 1 or 2 items and spread the load.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-4-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "5 flashes",
   "also_shown_as": "",
   "model": "Front load, LED (Diva Aqua)",
   "meaning": "Input voltage too high or too low (the manual lists 5 flashes for both)",
   "what_to_do": "The machine restarts by itself when voltage is safe. Call an electrician if it is frequent.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-5-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "7 flashes",
   "also_shown_as": "",
   "model": "Front load, LED (Diva Aqua)",
   "meaning": "Water above 60°C at start",
   "what_to_do": "Let it cool, or switch off for 2 seconds and restart.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-7-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "8 flashes",
   "also_shown_as": "",
   "model": "Front load, LED (Diva Aqua)",
   "meaning": "Not explained by IFB",
   "what_to_do": "Switch off, wait 2 seconds, restart. If it stays, close the tap and call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-8-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "tAP",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "No or low water: not filled within 10 minutes",
   "what_to_do": "Open the tap, clean the inlet filter, check the hot and cold hoses are not swapped, check water pressure.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-tap-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "drE",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Drain not finished in about 20 minutes",
   "what_to_do": "Check the drain hose is not blocked or kinked, its end is not under water and not more than 10 cm above the floor. Clean its filter.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-dre"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "UnbL",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Unbalanced, will not spin",
   "what_to_do": "The machine tries to correct it. Otherwise spread the laundry evenly and level the machine.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-unbl-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "dor",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Lid open",
   "what_to_do": "Close the lid.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-dor"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "ACH",
   "also_shown_as": "",
   "model": "Top load (TL-RES, TL650–TL801, TL100/TL900)",
   "meaning": "Input voltage too high",
   "what_to_do": "Restarts by itself. Call an electrician if it is frequent.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-ach"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "ACL",
   "also_shown_as": "",
   "model": "Top load (TL-RES, TL650–TL801, TL100/TL900)",
   "meaning": "Input voltage too low",
   "what_to_do": "Restarts by itself. Call an electrician if it is frequent.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-acl"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "FrH / FrL",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Supply frequency too high or too low",
   "what_to_do": "Restarts by itself. Call an electrician if it is frequent.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-frh-frl"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "LSE",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Load sensing error (also overload, motor, clutch or belt)",
   "what_to_do": "Switch off and on, run again. If it repeats, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-lse"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "PrS",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Water level sensing error (some models: motor open error)",
   "what_to_do": "Switch off, wait 2 seconds, restart. If it repeats, close the tap and call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-prs"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "E1, E2, E3",
   "also_shown_as": "",
   "model": "Top load TL100 / TL900 (9–10 kg)",
   "meaning": "Motor error",
   "what_to_do": "Switch off, wait a moment, restart. If it stays, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-e1-e2-e3"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "COn",
   "also_shown_as": "",
   "model": "Top load TL100 / TL900",
   "meaning": "Shown with the motor error entry; not explained by IFB",
   "what_to_do": "Switch off, restart. If it stays, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-con"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "eEr",
   "also_shown_as": "",
   "model": "Top load (some models)",
   "meaning": "Motor error",
   "what_to_do": "Switch off and on. If it stays, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-eer"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "HEt",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Overheating",
   "what_to_do": "Restart. If it repeats, call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-het"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "CPE",
   "also_shown_as": "",
   "model": "Top load",
   "meaning": "Capacitor error or overload",
   "what_to_do": "Call IFB Care.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-cpe"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "Lo",
   "also_shown_as": "LO",
   "model": "Top load Aqua (TL-REGS, REWS, RESS, RPSS, R1, R2 series)",
   "meaning": "Input voltage too low",
   "what_to_do": "Starts by itself when the voltage is safe. Call an electrician if it is frequent.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-lo"
  },
  {
   "appliance": "washing-machine",
   "brand": "IFB",
   "code": "Hi",
   "also_shown_as": "HI",
   "model": "Top load Aqua (TL-REGS, REWS, RESS, RPSS, R1, R2 series)",
   "meaning": "Input voltage too high",
   "what_to_do": "Starts by itself when the voltage is safe. Call an electrician if it is frequent.",
   "source": "https://www.ifbappliances.com/support/product-help/product/laundry-solutions/front-load/elena-sbs https://imagestore.ifbhub.com/Adobe/Manuals/bis/653_I.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/FL_Diva_Aqua_537_I.pdf https://www.ifbappliances.com/support/product-help/product/laundry-solutions/top-load/tl-res https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_300_D.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_360_UM.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_113_I_Manual.pdf https://imagestore.ifbhub.com/Adobe/Manuals/bis/TL_013_I.pdf",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/ifb/#code-hi"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "OE",
   "also_shown_as": "E03, E21",
   "model": "",
   "meaning": "Washer cannot drain water",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-oe"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "IE",
   "also_shown_as": "E02, E10",
   "model": "",
   "meaning": "Water inlet error: tub does not fill in time",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-ie"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "UE",
   "also_shown_as": "",
   "model": "",
   "meaning": "Load is unbalanced",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-ue"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "dE",
   "also_shown_as": "dE1, E01",
   "model": "",
   "meaning": "Door not closed properly",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-de"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "dE2",
   "also_shown_as": "E30",
   "model": "",
   "meaning": "Door closed but not locked",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-de2"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "LE",
   "also_shown_as": "",
   "model": "",
   "meaning": "Tub does not spin, often overload or something stuck",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-le"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "CE",
   "also_shown_as": "",
   "model": "",
   "meaning": "Over-current in the motor circuit",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-ce"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "FE",
   "also_shown_as": "E04, E12",
   "model": "",
   "meaning": "Water overfilling",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-fe"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "PE",
   "also_shown_as": "E33",
   "model": "",
   "meaning": "Water level sensor fault",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-pe"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "tE",
   "also_shown_as": "",
   "model": "",
   "meaning": "Heating error, usually the thermistor",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-te"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "AE",
   "also_shown_as": "",
   "model": "",
   "meaning": "Leak inside the machine, safety switch on",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-ae"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "PF",
   "also_shown_as": "",
   "model": "",
   "meaning": "Power failed during a cycle",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-pf"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "Sud",
   "also_shown_as": "",
   "model": "",
   "meaning": "Too much foam, extra cycle added",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-sud"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "CL",
   "also_shown_as": "",
   "model": "",
   "meaning": "Not an error: child lock is on",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-cl"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "tCL",
   "also_shown_as": "",
   "model": "",
   "meaning": "Not an error: time to run Tub Clean",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-tcl"
  },
  {
   "appliance": "washing-machine",
   "brand": "LG",
   "code": "Cd",
   "also_shown_as": "",
   "model": "",
   "meaning": "Not an error: cooling down after drying",
   "what_to_do": "",
   "source": "https://www.lg.com/lk/support/product-help/CT30012668-20155069444652",
   "checked": "2026-10-24",
   "url": "https://faultdecode.com/washing-machine/lg/#code-cd"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "1E",
   "also_shown_as": "1C, E7",
   "model": "",
   "meaning": "Water level sensor issue",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-1e"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "3E",
   "also_shown_as": "3C, 3E1–3E4, EA, EB",
   "model": "",
   "meaning": "Motor issue",
   "what_to_do": "Switch off at the mains for 1 minute, restart; call service if it stays",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-3e"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "3CP",
   "also_shown_as": "",
   "model": "",
   "meaning": "Electronic control issue",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-3cp"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "4C",
   "also_shown_as": "4E, E1",
   "model": "",
   "meaning": "Water supply issue",
   "what_to_do": "Open the tap fully, check the hose, clean the inlet filter",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-4c"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "4C2",
   "also_shown_as": "4E1, 4E2, 4Ed",
   "model": "",
   "meaning": "Water temperature issue",
   "what_to_do": "Check the inlet hose is on the cold water supply",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-4c2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "5E",
   "also_shown_as": "5C, E2",
   "model": "",
   "meaning": "Water drainage issue",
   "what_to_do": "Level the machine, straighten the drain hose, clean the debris filter (front load)",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-5e"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "6E",
   "also_shown_as": "E5, E6, HE1",
   "model": "",
   "meaning": "Water heater not functioning",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-6e"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "8C",
   "also_shown_as": "",
   "model": "",
   "meaning": "MEMS sensor issue",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-8c"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "8E",
   "also_shown_as": "",
   "model": "",
   "meaning": "Current error",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-8e"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "9C1",
   "also_shown_as": "9C2",
   "model": "",
   "meaning": "Low voltage",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-9c1"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "9E1",
   "also_shown_as": "9E2, 9H1, Plo",
   "model": "",
   "meaning": "Power error",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-9e1"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "UC",
   "also_shown_as": "",
   "model": "",
   "meaning": "Supply voltage fluctuation (Samsung UAE treats 9C1 and UC as one error)",
   "what_to_do": "Plug straight into a wall socket, no extension cable; restart",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-uc"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "LE",
   "also_shown_as": "LC, LC1, LE1, 11E, E9",
   "model": "",
   "meaning": "Low water level detected, or a leak",
   "what_to_do": "Check the drain hose is not on the floor or below the machine; look for leaks",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-le"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "bE1",
   "also_shown_as": "bE2, bE3, 12E, 14E",
   "model": "",
   "meaning": "Button issue (for example a jammed button)",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-be1"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "AC",
   "also_shown_as": "AE, AC6, 13E",
   "model": "",
   "meaning": "Signal communication error",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-ac"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "AE6",
   "also_shown_as": "",
   "model": "",
   "meaning": "Inverter communication issue",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-ae6"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "Cb",
   "also_shown_as": "",
   "model": "",
   "meaning": "Calibration mode, not a fault",
   "what_to_do": "Check the inlet hose is on the cold water supply",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-cb"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "CE",
   "also_shown_as": "",
   "model": "",
   "meaning": "Calibration, not a fault",
   "what_to_do": "Press Start/Pause to run the calibration cycle and wait for 0 when it is complete",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-ce"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "dE",
   "also_shown_as": "dC, DC",
   "model": "",
   "meaning": "Door issue: door open or not shut properly",
   "what_to_do": "Close the door fully, remove clothes caught in it, restart",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-de"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "DC3",
   "also_shown_as": "",
   "model": "",
   "meaning": "Add Door lock issue",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-dc3"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "ddC",
   "also_shown_as": "DDC",
   "model": "",
   "meaning": "Add Door opened without pressing Start/Pause",
   "what_to_do": "Close the Add Door and press Start/Pause",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-ddc"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "dE2",
   "also_shown_as": "",
   "model": "",
   "meaning": "On/Off switch error",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-de2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "OE",
   "also_shown_as": "OC, OF, E3",
   "model": "",
   "meaning": "Overflow error",
   "what_to_do": "Power off for 1 minute and let it drain; use less detergent",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-oe"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "UE",
   "also_shown_as": "Ub, E4, Ur",
   "model": "",
   "meaning": "Unbalanced load, not a fault",
   "what_to_do": "Spread the load out and don't overload",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-ue"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "tE",
   "also_shown_as": "tC, tE1–tE3, tC1–tC3, EC",
   "model": "",
   "meaning": "Temperature sensor error",
   "what_to_do": "Switch off at the mains for 30–60 seconds and restart",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-te"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "FE",
   "also_shown_as": "FC, OF",
   "model": "",
   "meaning": "Fan motor issue",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-fe"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "HE",
   "also_shown_as": "HC, H1, E8",
   "model": "",
   "meaning": "Water temperature issue",
   "what_to_do": "Check the inlet hose is on the cold supply",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-he"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "HE2",
   "also_shown_as": "",
   "model": "",
   "meaning": "Dryer section shut down for safety because it was getting too hot (washer-dryer)",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-he2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "HE3",
   "also_shown_as": "",
   "model": "",
   "meaning": "Steam fault",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-he3"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "HOT",
   "also_shown_as": "",
   "model": "",
   "meaning": "Drum too hot to open, not a fault",
   "what_to_do": "Wait for it to cool",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-hot"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "PC",
   "also_shown_as": "PC1, PE, PE1",
   "model": "",
   "meaning": "Clutch position detection issue",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-pc"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "Sud",
   "also_shown_as": "SUd, Sd, 5d, 5UD",
   "model": "",
   "meaning": "Too much foam detected, not a fault",
   "what_to_do": "Let it clear; use less detergent",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-sud"
  },
  {
   "appliance": "washing-machine",
   "brand": "Samsung",
   "code": "t1",
   "also_shown_as": "t2, tSt",
   "model": "",
   "meaning": "Test mode, not a fault",
   "what_to_do": "",
   "source": "https://www.samsung.com/uk/support/home-appliances/what-do-the-codes-on-my-washing-machine-mean/ https://www.samsung.com/us/support/troubleshoot/TSG10000997/ https://www.samsung.com/au/support/home-appliances/samsung-washing-machine-error-codes/ https://www.samsung.com/in/support/home-appliances/how-to-resolve-4e-or-5e-codes-on-your-samsung-washing-machine/ https://www.samsung.com/in/support/home-appliances/how-to-fix-de-dc-error-in-samsung-washing-machine/ https://www.samsung.com/levant/support/home-appliances/washing-machine-what-does-the-error-code-means-and-how-to-fix-it/ https://www.samsung.com/sg/support/home-appliances/check-out-the-information-codes-on-my-washing-machine/ https://www.samsung.com/ae/support/home-appliances/how-to-fix-the-washing-machine-with-9c1uc-error/ https://www.samsung.com/in/support/home-appliances/how-to-fix-error-codes-in-front-load-washer-dryer-combo/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/washing-machine/samsung/#code-t1"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH00",
   "also_shown_as": "",
   "model": "",
   "meaning": "Unit needs inspection (also a blinking LED)",
   "what_to_do": "Reset the power for 5 minutes; if it stays, call service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch00"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH01",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Indoor room air sensor (thermistor) disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch01"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH02",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Indoor inlet pipe sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch02"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH04",
   "also_shown_as": "FL",
   "model": "Window, portable, ceiling",
   "meaning": "Drain problem or condensate tank full",
   "what_to_do": "Window/portable: unplug and drain the water as the manual shows. Ceiling: reset power, then service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch04"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH05",
   "also_shown_as": "CH 05, CH5, E0",
   "model": "",
   "meaning": "Indoor and outdoor units not communicating (LG groups it with E0 and CH53)",
   "what_to_do": "Reset the power for 5 minutes; if it stays, call service. On some models, EO during kW Manager operation is normal, not an error",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch05"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH06",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Indoor outlet pipe sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch06"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH07",
   "also_shown_as": "",
   "model": "2-in-1 / multi",
   "meaning": "Indoor units set to different modes",
   "what_to_do": "Set all units to the same mode (all cooling/dry or all heating)",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch07"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH09",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Indoor memory (EEPROM) error",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch09"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH10",
   "also_shown_as": "CH 10, E6",
   "model": "",
   "meaning": "Indoor fan motor problem (fan locked or not running)",
   "what_to_do": "Clear visible debris, reset power; if it stays, call service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch10"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH12",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Indoor middle pipe sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch12"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH21",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Inverter power module (IPM / DC peak) fault",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch21"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH22",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Input current too high",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch22"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH23",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "DC link voltage too low",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch23"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH25",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Supply voltage too low or too high",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch25"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH26",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Inverter compressor not starting or locked",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch26"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH27",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "PSC fault",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch27"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH28",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Compressor DC voltage too high",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch28"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH29",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Compressor current too high",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch29"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH31",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Current sensor reading too low",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch31"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH32",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Compressor discharge pipe too hot",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch32"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH38",
   "also_shown_as": "F4",
   "model": "",
   "meaning": "Low refrigerant (gas)",
   "what_to_do": "New installation: call the installer. Otherwise reset power, then LG service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch38"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH40",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Current sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch40"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH41",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Discharge pipe sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch41"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH44",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Outdoor air sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch44"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH45",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Condenser middle sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch45"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH46",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Suction pipe sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch46"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH48",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Liquid pipe sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch48"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH53",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Outdoor to indoor communication failure",
   "what_to_do": "Reset the power; if it stays, call service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch53"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH54",
   "also_shown_as": "",
   "model": "",
   "meaning": "Reverse phase detected (after a power cut or electrical work)",
   "what_to_do": "Reset the breaker; ask your electrician or LG service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch54"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH60",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Outdoor memory (EEPROM) error",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch60"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH61",
   "also_shown_as": "P4, P6, P7, P8, CH34 on some models",
   "model": "",
   "meaning": "Overheating protection (outdoor unit in cooling, indoor in heating)",
   "what_to_do": "Clear space around the outdoor unit and improve air flow; in heating, clean the indoor filter. Then reset the power: LG says CH61 does not clear on its own",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch61"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH62",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Outdoor heat sink too hot",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch62"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH63",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Condenser pipe temperature too low",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch63"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH65",
   "also_shown_as": "",
   "model": "Split",
   "meaning": "Heat sink sensor disconnected or shorted",
   "what_to_do": "",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch65"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH66",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Problem with the indoor-outdoor communication line or piping connection",
   "what_to_do": "New installation: call the installer. Otherwise reset, then service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch66"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH67",
   "also_shown_as": "EF",
   "model": "",
   "meaning": "Outdoor fan motor problem (fan locked)",
   "what_to_do": "Clear visible debris around the outdoor fan, reset power; if it stays, call service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch67"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH90",
   "also_shown_as": "CH91, F4 on some models",
   "model": "",
   "meaning": "Test-run protection after installation",
   "what_to_do": "Ask the installer to check the piping; otherwise reset, then service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch90"
  },
  {
   "appliance": "ac",
   "brand": "LG",
   "code": "CH93",
   "also_shown_as": "",
   "model": "",
   "meaning": "Unstable indoor-outdoor communication; on 2021+ models the outdoor unit may have no power",
   "what_to_do": "Check both power cords and breakers; if it stays, call service",
   "source": "https://www.lg.com/us/support/help-library/lg-air-conditioner-guide-to-error-codes--20155047719306 https://www.lg.com/ca_en/support/product-support/troubleshoot/help-library/cs-CT30000386-20153289364119/",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/ac/lg/#code-ch93"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C101 / E101",
   "also_shown_as": "C102 / E102, E202",
   "model": "",
   "meaning": "Indoor and outdoor units not communicating",
   "what_to_do": "Installer: check the connecting cables are not swapped",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c101-e101"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C102",
   "also_shown_as": "",
   "model": "",
   "meaning": "On some installs, refrigerant not reaching the indoor unit (Smart Install guide)",
   "what_to_do": "Installer: check valves and leaks",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c102"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C121 / E121",
   "also_shown_as": "",
   "model": "",
   "meaning": "Room temperature sensor defective",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c121-e121"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C122 / E122",
   "also_shown_as": "",
   "model": "",
   "meaning": "Heat exchanger temperature sensor defective",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c122-e122"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C123",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor coil (evaporator) sensor error",
   "what_to_do": "Installer: check the sensor connection",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c123"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C154 / E154",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor fan not rotating (fan motor or capacitor), or high-voltage protection",
   "what_to_do": "Restart once; if it returns within 10 seconds, call service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c154-e154"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C162 / E162",
   "also_shown_as": "88",
   "model": "",
   "meaning": "Option data error in the control board",
   "what_to_do": "Installer resets the option codes",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c162-e162"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C163 / E163",
   "also_shown_as": "",
   "model": "",
   "meaning": "Wrong or missing data in the control board memory (EEPROM)",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c163-e163"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E186",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor MPI feedback error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e186"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E203",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor board and inverter not communicating",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e203"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E221 / E237",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor temperature sensor error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e221-e237"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E251",
   "also_shown_as": "",
   "model": "",
   "meaning": "Discharge temperature sensor error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e251"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E416",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor discharge temperature too high",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e416"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C422",
   "also_shown_as": "",
   "model": "",
   "meaning": "Refrigerant flow blocked",
   "what_to_do": "Installer: check valves are fully open and pipes are not blocked or leaking",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c422"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E458",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor fan error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e458"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E461",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor start failure",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e461"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E462",
   "also_shown_as": "",
   "model": "",
   "meaning": "Input overcurrent (I-trip / PFC)",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e462"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E464",
   "also_shown_as": "",
   "model": "",
   "meaning": "Inverter module (IPM) overcurrent",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e464"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E465",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor voltage limit",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e465"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E467",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor rotation error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e467"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E468",
   "also_shown_as": "",
   "model": "",
   "meaning": "Current sensor error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e468"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E469",
   "also_shown_as": "",
   "model": "",
   "meaning": "DC voltage sensor error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e469"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E471",
   "also_shown_as": "",
   "model": "",
   "meaning": "OTP error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e471"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E472",
   "also_shown_as": "",
   "model": "",
   "meaning": "AC voltage signal error",
   "what_to_do": "Call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e472"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "C554 / E554",
   "also_shown_as": "",
   "model": "",
   "meaning": "Lack of refrigerant or gas leak (inverter models)",
   "what_to_do": "Switch off and call Samsung service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-c554-e554"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "E556",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor and outdoor capacity mismatch",
   "what_to_do": "Installer to check",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-e556"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "EC",
   "also_shown_as": "",
   "model": "",
   "meaning": "Gas leak detected or sensor not working",
   "what_to_do": "Switch off at the mains once; if it returns, call service",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-ec"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "CH / CF",
   "also_shown_as": "",
   "model": "",
   "meaning": "Filter cleaning reminder, not a fault",
   "what_to_do": "Clean the filter. CH: press Temp Up and Temp Down together. CF: Options > Filter Reset > SET",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-ch-cf"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "CI / C1",
   "also_shown_as": "",
   "model": "",
   "meaning": "Auto clean running, not a fault",
   "what_to_do": "No action needed; Samsung says it can be cancelled from Options > Clean > SET",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-ci-c1"
  },
  {
   "appliance": "ac",
   "brand": "Samsung",
   "code": "dF",
   "also_shown_as": "",
   "model": "",
   "meaning": "Defrost in heating mode, not a fault",
   "what_to_do": "",
   "source": "https://www.samsung.com/in/support/home-appliances/error-codes-on-your-samsung-indoor-air-conditioner/ https://www.samsung.com/in/support/home-appliances/samsung-ac-smart-install-guide/ https://www.samsung.com/in/support/home-appliances/ch-error-display-on-the-panel/ https://www.samsung.com/in/support/home-appliances/how-to-decode-error-messages-in-your-inverter-air-conditioner https://www.samsung.com/tr/support/home-appliances/what-are-samsung-air-conditioner-error-codes-and-solutions https://www.samsung.com/in/support/home-appliances/filter-choke-indicator-appears-on-the-panel/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/samsung/#code-df"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "EE",
   "also_shown_as": "indoor LED 25 flashes, outdoor 25",
   "model": "Inverter split",
   "meaning": "Indoor unit memory (EE) fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-ee"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E0",
   "also_shown_as": "indoor LED 1 flashes, outdoor 1",
   "model": "Inverter split",
   "meaning": "Outdoor unit memory (EE) fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e0"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E1",
   "also_shown_as": "indoor LED 26 flashes, outdoor 26",
   "model": "Inverter split",
   "meaning": "Indoor fan fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e1"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E2",
   "also_shown_as": "indoor LED 27 flashes, outdoor 27",
   "model": "Inverter split",
   "meaning": "Indoor fan zero-crossing detection abnormal",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E3",
   "also_shown_as": "indoor LED 28 flashes, outdoor 28",
   "model": "Inverter split",
   "meaning": "Indoor coil fault and coil sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e3"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E4",
   "also_shown_as": "indoor LED 29 flashes, outdoor 29",
   "model": "Inverter split",
   "meaning": "Indoor room temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e4"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E5",
   "also_shown_as": "indoor LED 30 flashes, outdoor 30",
   "model": "Inverter split",
   "meaning": "Refrigerant leak fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e5"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E6",
   "also_shown_as": "indoor LED 2 flashes, outdoor 2",
   "model": "Inverter split",
   "meaning": "Indoor and outdoor units not communicating",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e6"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E9 / EF",
   "also_shown_as": "indoor LED 3 flashes",
   "model": "Inverter split",
   "meaning": "Wi-Fi module fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e9-ef"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "EH",
   "also_shown_as": "indoor LED 24 flashes, outdoor 24",
   "model": "Inverter split",
   "meaning": "Humidity sensor fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-eh"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "EP",
   "also_shown_as": "indoor LED 37 flashes",
   "model": "Inverter split",
   "meaning": "PM2.5 sensor fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-ep"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "EU",
   "also_shown_as": "indoor LED 38 flashes",
   "model": "Inverter split",
   "meaning": "Voice module communication fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-eu"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F1",
   "also_shown_as": "indoor LED 4 flashes, outdoor 4",
   "model": "Inverter split",
   "meaning": "Compressor start abnormal or phase failure",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f1"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F2",
   "also_shown_as": "indoor LED 5 flashes, outdoor 5",
   "model": "Inverter split",
   "meaning": "Compressor out-of-step fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F3",
   "also_shown_as": "indoor LED 6 flashes, outdoor 6",
   "model": "Inverter split",
   "meaning": "IPM (inverter power module) fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f3"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F4",
   "also_shown_as": "indoor LED 7 flashes, outdoor 7",
   "model": "Inverter split",
   "meaning": "Compressor shell top fault or protection",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f4"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F5",
   "also_shown_as": "indoor LED 8 flashes, outdoor 8",
   "model": "Inverter split",
   "meaning": "Discharge temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f5"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F6",
   "also_shown_as": "indoor LED 9 flashes, outdoor 9",
   "model": "Inverter split",
   "meaning": "Suction temperature sensor fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f6"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F7",
   "also_shown_as": "indoor LED 10 flashes, outdoor 10",
   "model": "Inverter split",
   "meaning": "Outdoor coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f7"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F8",
   "also_shown_as": "indoor LED 11 flashes, outdoor 11",
   "model": "Inverter split",
   "meaning": "Outdoor air temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f8"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F9",
   "also_shown_as": "indoor LED 12 flashes, outdoor 12",
   "model": "Inverter split",
   "meaning": "Outdoor DC fan fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f9"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P1",
   "also_shown_as": "indoor LED 13 flashes, outdoor 13",
   "model": "Inverter split",
   "meaning": "Outdoor unit AC current protection",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p1"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P2",
   "also_shown_as": "indoor LED 14 flashes, outdoor 14",
   "model": "Inverter split",
   "meaning": "Compressor phase current protection",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P3",
   "also_shown_as": "indoor LED 15 flashes, outdoor 15",
   "model": "Inverter split",
   "meaning": "Outdoor unit supply voltage too high or too low",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p3"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P4",
   "also_shown_as": "indoor LED 16 flashes, outdoor 16",
   "model": "Inverter split",
   "meaning": "DC voltage too high or too low",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p4"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P5",
   "also_shown_as": "indoor LED 17 flashes, outdoor 17",
   "model": "Inverter split",
   "meaning": "IPM over-temperature protection",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p5"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P6",
   "also_shown_as": "indoor LED 18 flashes, outdoor 18",
   "model": "Inverter split",
   "meaning": "Discharge temperature overheat protection",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p6"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P7",
   "also_shown_as": "indoor LED 19 flashes, outdoor 19",
   "model": "Inverter split",
   "meaning": "Indoor coil anti-freeze protection in cooling",
   "what_to_do": "The AC is defrosting the indoor coil in cooling; the code shows for some time while frost is removed",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p7"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P8",
   "also_shown_as": "indoor LED 20 flashes, outdoor 20",
   "model": "Inverter split",
   "meaning": "Outdoor coil overheat protection in cooling",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p8"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P9",
   "also_shown_as": "indoor LED 21 flashes, outdoor 21",
   "model": "Inverter split",
   "meaning": "Indoor coil overheat protection in heating (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p9"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "PC",
   "also_shown_as": "indoor LED 22 flashes, outdoor 22",
   "model": "Inverter split",
   "meaning": "Outdoor temperature too low for cooling",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-pc"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "PH",
   "also_shown_as": "indoor LED 23 flashes, outdoor 23",
   "model": "Inverter split",
   "meaning": "Outdoor temperature too high for heating (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-ph"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "L1",
   "also_shown_as": "indoor LED 31 flashes, outdoor 31",
   "model": "Inverter split",
   "meaning": "Drive bus voltage too high",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-l1"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "L2",
   "also_shown_as": "indoor LED 32 flashes, outdoor 32",
   "model": "Inverter split",
   "meaning": "Drive bus voltage too low",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-l2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "L3",
   "also_shown_as": "indoor LED 33 flashes, outdoor 33",
   "model": "Inverter split",
   "meaning": "Drive phase current overload fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-l3"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "L4",
   "also_shown_as": "indoor LED 34 flashes, outdoor 34",
   "model": "Inverter split",
   "meaning": "Phase current sampling abnormal",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-l4"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E1",
   "also_shown_as": "indoor LED 29 flashes",
   "model": "Split (non-inverter)",
   "meaning": "Indoor room temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e1-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E2",
   "also_shown_as": "indoor LED 28 flashes",
   "model": "Split (non-inverter)",
   "meaning": "Indoor coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e2-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E5 / H6",
   "also_shown_as": "indoor LED 26 flashes",
   "model": "Split (non-inverter)",
   "meaning": "Indoor fan motor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e5-h6"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "dF",
   "also_shown_as": "indoor LED 19 flashes",
   "model": "Split (non-inverter)",
   "meaning": "Indoor defrost protection in cooling",
   "what_to_do": "The AC is defrosting the indoor coil in cooling; the code shows for some time while frost is removed",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-df"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E3",
   "also_shown_as": "",
   "model": "Split (non-inverter)",
   "meaning": "Outdoor coil temperature sensor fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e3-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "HP",
   "also_shown_as": "indoor LED 21 flashes",
   "model": "Split (non-inverter)",
   "meaning": "Indoor coil overheat protection in heating (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-hp"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "HF",
   "also_shown_as": "",
   "model": "Split (non-inverter)",
   "meaning": "Outdoor defrost protection in heating (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-hf"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "CL",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Filter cleaning reminder (selected models)",
   "what_to_do": "Clean the filter (remove, brush or vacuum, wash under running water, air-dry out of direct sun, refit). Newer manual: reset the reminder by pressing TURBO for 5 seconds. On side display type B the Power (green) LED blinks while the reminder is on.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-cl"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "go",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Intelligent Diagnosis passed: the self-test found no fault (selected models)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-go"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "ng",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Intelligent Diagnosis found a fault: the Sleep LED (red) blinks the error code and the buzzer beeps 5 times (selected models)",
   "what_to_do": "The manual gives no fix. Note the error and call Lloyd service.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-ng"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "Ht",
   "also_shown_as": "",
   "model": "Both",
   "meaning": "Heat mode indication, not a fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-ht"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P3 01",
   "also_shown_as": "no LED flash",
   "model": "Inverter split",
   "meaning": "Low voltage indication / notification (newer manual)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p3-01"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "P3 02",
   "also_shown_as": "no LED flash",
   "model": "Inverter split",
   "meaning": "High voltage indication / notification (newer manual)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-p3-02"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "PE",
   "also_shown_as": "outdoor light 39 flashes, no indoor flash",
   "model": "Inverter split",
   "meaning": "Earth fault protection (newer manual)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-pe"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "LO / Lb",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Remote control battery low: the remote handset shows Lb or Lo (newer manual)",
   "what_to_do": "Replace the two AAA 1.5 V batteries in the remote.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-lo-lb"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "do",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Door open alert: room temperature keeps rising, so the AC warns of low cooling, as from an open door. Shows \"do\" for a few seconds with a beep (selected models, newer manual p.37)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-do"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "dg",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "DG mode is on (switched on with the DG key, for running on a diesel generator). \"dg\" shows continuously; switching the AC off and on at the power switch ends it (newer manual p.42)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-dg"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "Ic",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Ice Clean is running: \"Ic\" blinks during the 20-30 minute self-clean, then the AC goes to standby (newer manual p.43)",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-ic"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E1",
   "also_shown_as": "",
   "model": "Window AC (fixed speed)",
   "meaning": "Ambient / room temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e1-3"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "E2",
   "also_shown_as": "",
   "model": "Window AC (fixed speed)",
   "meaning": "Evaporator / coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-e2-3"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "dF",
   "also_shown_as": "",
   "model": "Window AC (fixed speed)",
   "meaning": "Defrost protection",
   "what_to_do": "",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-df-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "CL",
   "also_shown_as": "",
   "model": "Window AC (fixed speed)",
   "meaning": "Filter cleaning reminder (not a fault)",
   "what_to_do": "Clean the filter (remove, brush or vacuum, wash under running water, air-dry, refit), then press TURBO four times to reset the reminder.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-cl-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F1",
   "also_shown_as": "",
   "model": "Window AC (fixed speed), touch panel display",
   "meaning": "Fan speed LOW selected (not an error)",
   "what_to_do": "Nothing to fix. This is a display setting, not an error.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f1-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F2",
   "also_shown_as": "",
   "model": "Window AC (fixed speed), touch panel display",
   "meaning": "Fan speed MEDIUM selected (not an error)",
   "what_to_do": "Nothing to fix. This is a display setting, not an error.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f2-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "F3",
   "also_shown_as": "",
   "model": "Window AC (fixed speed), touch panel display",
   "meaning": "Fan speed HIGH selected (not an error)",
   "what_to_do": "Nothing to fix. This is a display setting, not an error.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-f3-2"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "FA",
   "also_shown_as": "",
   "model": "Window AC (fixed speed), touch panel display",
   "meaning": "Auto fan speed selected (not an error)",
   "what_to_do": "Nothing to fix. This is a display setting, not an error.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-fa"
  },
  {
   "appliance": "ac",
   "brand": "Lloyd",
   "code": "Co / dY / Fn / AU",
   "also_shown_as": "",
   "model": "Window AC (fixed speed), touch panel display",
   "meaning": "Mode shown on the display: Co = Cool, dY = Dry, Fn = Fan, AU = Auto (not an error)",
   "what_to_do": "Nothing to fix. This is a display setting, not an error.",
   "source": "https://havells.com/media/wysiwyg/Manuals/lloyd-AC-common.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-pulse-new-remote.pdf https://havells.com/media/wysiwyg/Manuals/lloyd-AC-window.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/lloyd/#code-co-dy-fn-au"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "Lbt",
   "also_shown_as": "Battery Low",
   "model": "Zelio+ (1100, 1700)",
   "meaning": "Battery low; the battery may be discharged",
   "what_to_do": "Recharge the battery when mains is available",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-lbt"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "oLd",
   "also_shown_as": "OVERLOAD",
   "model": "Zelio+ (1100, 1700)",
   "meaning": "UPS tripped because the load is too high",
   "what_to_do": "Reduce the load and reset the power switch",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-old"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "Mains indicator off",
   "also_shown_as": "UPS working on battery",
   "model": "Zelio+ (1100, 1700)",
   "meaning": "Mains is normal but the UPS is not taking it: loose plug, dead socket, MCB trip, or mains too low or high",
   "what_to_do": "Fit the plug properly, check the socket and MCB, or wait for mains to normalise",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-mains-indicator-off"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "Mains ON but no output",
   "also_shown_as": "",
   "model": "Zelio+ (1100, 1700)",
   "meaning": "Mains indicator glows but there is no output; the output plug may be loose",
   "what_to_do": "Fit the output plug properly",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-mains-on-but-no-output"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "ON MAINS off",
   "also_shown_as": "UPS/ECO or LOW BATT. glowing",
   "model": "Eco Volt Neo (750–1650)",
   "meaning": "Mains is normal but the unit is on battery: loose plug, dead socket, mains too low or high, or a blown fuse / tripped MCB",
   "what_to_do": "Fit the plug, check the socket with a lamp, wait for mains to normalise, or replace the fuse with the same rating / reset the MCB",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-on-mains-off"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "LOW BATT. glowing",
   "also_shown_as": "all other indicators off",
   "model": "Eco Volt Neo (750–1650)",
   "meaning": "In battery mode, the battery has been discharged by recent use",
   "what_to_do": "Recharge the battery after mains comes back",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-low-batt-glowing"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "UPS OVERLOAD steady",
   "also_shown_as": "all other indicators off",
   "model": "Eco Volt Neo (750–1650)",
   "meaning": "The unit tripped on overload",
   "what_to_do": "Reduce the load and switch the front-panel reset switch off and on",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-ups-overload-steady"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Luminous",
   "code": "OVERLOAD blinking",
   "also_shown_as": "all other indicators off",
   "model": "Eco Volt Neo (750–1650)",
   "meaning": "The unit tripped because of a short circuit in UPS mode",
   "what_to_do": "Switch off all loads, then turn them on one by one. If OVERLOAD blinks again, call an authorised technician",
   "source": "https://www.manualslib.com/manual/4114368/Luminous-ZelioPlus.html https://www.manualslib.com/manual/4160929/Luminous-Eco-Volt-Neo-750.html https://www.luminousindia.com/support",
   "checked": "2026-10-25",
   "url": "https://faultdecode.com/inverter-ups/luminous/#code-overload-blinking"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H00",
   "also_shown_as": "",
   "model": "",
   "meaning": "No fault stored in memory",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h00"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H11",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor and outdoor units not communicating",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h11"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H12",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor unit capacity does not match",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h12"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H14",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor intake air temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h14"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H15",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h15"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H16",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor current transformer fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h16"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H17",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor suction temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h17"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H19",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor fan motor locked",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h19"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H21",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor float switch malfunction",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h21"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H23",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor heat exchanger temperature sensor 1 fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h23"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H24",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor heat exchanger temperature sensor 2 fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h24"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H25",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor ion device fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h25"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H26",
   "also_shown_as": "",
   "model": "",
   "meaning": "Negative ion fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h26"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H27",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor air temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h27"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H28",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor heat exchanger temperature sensor 1 fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h28"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H30",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor discharge pipe temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h30"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H31",
   "also_shown_as": "",
   "model": "",
   "meaning": "Swimming pool sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h31"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H32",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor heat exchanger temperature sensor 2 fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h32"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H33",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor and outdoor units misconnected",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h33"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H34",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor heat sink temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h34"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H35",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor/outdoor water adverse current fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h35"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H36",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor gas pipe temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h36"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H37",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor liquid pipe temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h37"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H38",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor and outdoor brand code mismatch",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h38"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H39",
   "also_shown_as": "",
   "model": "",
   "meaning": "Abnormal indoor operating or standby unit",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h39"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H41",
   "also_shown_as": "",
   "model": "",
   "meaning": "Wiring or piping connection fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h41"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H50",
   "also_shown_as": "",
   "model": "",
   "meaning": "Ventilation fan motor locked",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h50"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H51",
   "also_shown_as": "",
   "model": "",
   "meaning": "Ventilation fan motor locked",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h51"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H52",
   "also_shown_as": "",
   "model": "",
   "meaning": "Left-right limit switch fixing fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h52"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H58",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor gas sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h58"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H59",
   "also_shown_as": "",
   "model": "",
   "meaning": "Eco sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h59"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H64",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor high-pressure sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h64"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H67",
   "also_shown_as": "",
   "model": "",
   "meaning": "nanoe fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h67"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H70",
   "also_shown_as": "",
   "model": "",
   "meaning": "Light sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h70"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H71",
   "also_shown_as": "",
   "model": "",
   "meaning": "Control board internal DC cooling fan fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h71"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H72",
   "also_shown_as": "",
   "model": "",
   "meaning": "Tank temperature sensor fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h72"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H79",
   "also_shown_as": "",
   "model": "",
   "meaning": "Wireless LAN module write error",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h79"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H85",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor unit and wireless LAN module communication fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h85"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H97",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor fan motor locked",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h97"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H98",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor high-pressure protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h98"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "H99",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor operating unit freeze protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-h99"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F11",
   "also_shown_as": "",
   "model": "",
   "meaning": "4-way valve switching fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f11"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F16",
   "also_shown_as": "",
   "model": "",
   "meaning": "Total running current protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f16"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F17",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor standby unit freezing fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f17"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F18",
   "also_shown_as": "",
   "model": "",
   "meaning": "Dry circuit blocked",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f18"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F87",
   "also_shown_as": "",
   "model": "",
   "meaning": "Control box overheat protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f87"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F90",
   "also_shown_as": "",
   "model": "",
   "meaning": "PFC circuit protection or compressor microcomputer communication error",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f90"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F91",
   "also_shown_as": "",
   "model": "",
   "meaning": "Refrigerant cycle fault",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f91"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F93",
   "also_shown_as": "",
   "model": "",
   "meaning": "Abnormal compressor speed",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f93"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F94",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor discharge pressure protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f94"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F95",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor high-pressure protection (cooling)",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f95"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F96",
   "also_shown_as": "",
   "model": "",
   "meaning": "Power transistor module overheating protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f96"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F97",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor overheating protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f97"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F98",
   "also_shown_as": "",
   "model": "",
   "meaning": "Total running current protection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f98"
  },
  {
   "appliance": "ac",
   "brand": "Panasonic",
   "code": "F99",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor DC peak detection",
   "what_to_do": "",
   "source": "https://www.panasonic.com/ph/air-solutions/learn-more/panasonic-air-conditioner-error-codes-using-the-self-diagnosis-function.html https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12VKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-XS12UKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-U12UKY.pdf https://www.panasonic.com/content/dam/panasonic/sg/en/CS-Page/Download-FAQ/Aircon%20FAQ.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-NU12WKYW%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-KU12WKY%20series.pdf https://www.panasonic.com/content/dam/panasonic/in/en/pdf/CS-WU12WKY%20series.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/panasonic/#code-f99"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E1 / E2",
   "also_shown_as": "",
   "model": "HD4928, HD4929",
   "meaning": "Main sensor open circuit or short circuit",
   "what_to_do": "Switch off from the main supply and on again (Philips India support page, which also covers the HD4938); if the code stays, contact Philips or an authorised service centre",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e1-e2"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E3 / E4",
   "also_shown_as": "",
   "model": "HD4928, HD4929",
   "meaning": "Heat sink sensor open circuit or short circuit",
   "what_to_do": "Switch off from the main supply and on again (Philips India support page, which also covers the HD4938); if the code stays, contact Philips or an authorised service centre",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e3-e4"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E5 / E6",
   "also_shown_as": "",
   "model": "HD4928, HD4929, HD4938",
   "meaning": "Voltage too high or too low",
   "what_to_do": "Wait for the voltage (needs 220 V to 240 V) to stabilise, then switch off and on again",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e5-e6"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E7",
   "also_shown_as": "",
   "model": "HD4928, HD4929, HD4938",
   "meaning": "Fan malfunction",
   "what_to_do": "Unplug, turn it over and clear fluff from the fan blades with a cotton bud; if E7 stays, contact Philips",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e7"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E8",
   "also_shown_as": "",
   "model": "HD4928, HD4929",
   "meaning": "Main sensor not working",
   "what_to_do": "Switch off from the main supply and on again (Philips India support page, which also covers the HD4938); if the code stays, contact Philips or an authorised service centre",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e8"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E9",
   "also_shown_as": "",
   "model": "HD4928, HD4929",
   "meaning": "Fuse malfunction",
   "what_to_do": "Switch off from the main supply and on again (Philips India support page, which also covers the HD4938); if the code stays, contact Philips or an authorised service centre",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e9"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E5 / E6",
   "also_shown_as": "",
   "model": "HD4911, HD4932, HD4953, HD4991",
   "meaning": "Voltage too low or too high, power cord or socket too hot, or too many appliances on one connector",
   "what_to_do": "Check the voltage, check the cord and socket are not hot, unplug other appliances on the same connector",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e5-e6-2"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E0 / E1 / E2 / E3 / E4 / E8 / Ed",
   "also_shown_as": "",
   "model": "HD4911, HD4932, HD4953",
   "meaning": "Cooker malfunction",
   "what_to_do": "Take it to a Philips dealer or a Philips authorised service centre",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e0-e1-e2-e3-e4-e8-ed"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E0 / E1 / E2 / E3 / E4 / E8 / E9",
   "also_shown_as": "",
   "model": "HD4991",
   "meaning": "Cooker malfunction",
   "what_to_do": "Take it to a Philips dealer or a Philips authorised service centre",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e0-e1-e2-e3-e4-e8-e9"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E7",
   "also_shown_as": "",
   "model": "HD4911, HD4932, HD4953",
   "meaning": "Overheating protection: the cooker stops heating",
   "what_to_do": "Check if it ran for 2 hours, the air outlets are blocked or the room is too hot; let it cool",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e7-2"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E1",
   "also_shown_as": "",
   "model": "HD4917, HD4918, HD4922",
   "meaning": "Unstable voltage in the power supply",
   "what_to_do": "Check the voltage in your home suits the cooker",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e1"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E2",
   "also_shown_as": "",
   "model": "HD4917, HD4918, HD4922",
   "meaning": "Cooking plate overheated",
   "what_to_do": "Switch off, unplug, let it cool about 10 minutes, switch on again",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e2"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E3",
   "also_shown_as": "",
   "model": "HD4917, HD4918, HD4922",
   "meaning": "Appliance malfunction",
   "what_to_do": "Take it to a Philips dealer or a Philips authorised service centre",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e3"
  },
  {
   "appliance": "induction",
   "brand": "Philips",
   "code": "E4",
   "also_shown_as": "",
   "model": "HD4917, HD4918, HD4922",
   "meaning": "Appliance overheated",
   "what_to_do": "Uncover the air outlet and let it cool; if the fan does not work, service",
   "source": "https://www.philips.co.in/c-f/XC000020673/my-philips-induction-cooktop-shows-an-error-code https://www.documents.philips.com/assets/20210429/fd72ad545f4048d88469ad1900b60a97.pdf https://www.documents.philips.com/assets/20210424/843c84998cb74db7a14dad1400954bba.pdf https://www.documents.philips.com/assets/20210504/8482937e0608495ba6e5ad1e014ce2ca.pdf https://www.documents.philips.com/assets/20210429/3fc40a55614046e38a6ead1900b89f8a.pdf https://www.documents.philips.com/assets/20210505/d5c9fcc3a7f342d4911fad1f008715f8.pdf https://www.documents.philips.com/assets/20210527/57ce935205f742fab231ad3501844f5c.pdf https://www.documents.philips.com/assets/20210504/038b776cc3b34159a75dad1e014ecdc3.pdf",
   "checked": "2026-11-24",
   "url": "https://faultdecode.com/induction/philips/#code-e4"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "EC",
   "also_shown_as": "run light flashes 7 times, timer light off",
   "model": "Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)",
   "meaning": "Refrigerant leakage detected (optional feature)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-ec"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "CL",
   "also_shown_as": "run and timer lights flash",
   "model": "Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)",
   "meaning": "Filter cleaning reminder after 240 hours of use (not a fault)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-cl"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "nF",
   "also_shown_as": "run and timer lights flash",
   "model": "Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)",
   "meaning": "Filter replacement reminder after 2,880 hours of use (not a fault)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-nf"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E0, E1, E2…",
   "also_shown_as": "also P1, P2, P3… and F1, F2, F3…",
   "model": "Split AC (Xcel Indus, Xtreme, Durawhite Pro+ / Ester+)",
   "meaning": "Error code. Wait about 10 minutes; if it stays, power off and on; if it persists, call service",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e0-e1-e2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E5/H6",
   "also_shown_as": "",
   "model": "Split AC, Xtreme fixed speed 12K/18K",
   "meaning": "Indoor unit fan motor protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e5-h6"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E1",
   "also_shown_as": "shows with set temperature, every 4 seconds",
   "model": "Split AC, Xtreme fixed speed 12K/18K",
   "meaning": "Room sensor error",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e1"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E2",
   "also_shown_as": "shows with set temperature, every 4 seconds",
   "model": "Split AC, Xtreme fixed speed 12K/18K",
   "meaning": "Evaporator sensor error",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "dF",
   "also_shown_as": "",
   "model": "Split AC, Xtreme fixed speed 12K/18K",
   "meaning": "Frost protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-df"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "CL",
   "also_shown_as": "shown during self clean",
   "model": "Split AC, Durawhite Pro+ / Ester+ 12K/18K",
   "meaning": "Self clean running (press Self Clean for 5 seconds to start)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-cl-2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E5",
   "also_shown_as": "inverter models only",
   "model": "Split AC, Durawhite Pro+ / Ester+ 12K/18K",
   "meaning": "Gas (refrigerant) leakage",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e5"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E1",
   "also_shown_as": "blinks; compressor runs 20 min on, 7 min off",
   "model": "Window AC, Estrella (fixed speed)",
   "meaning": "Room sensor failure or missing. Carrier: check the sensor, contact your Carrier dealer if not fixed",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e1-2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E2",
   "also_shown_as": "blinks; compressor runs 20 min on, 7 min off",
   "model": "Window AC, Estrella (fixed speed), R32 models only",
   "meaning": "Coil sensor failure or missing. Carrier: check the sensor, contact your Carrier dealer if not fixed",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e2-2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E1",
   "also_shown_as": "",
   "model": "Window AC, Estrella Inverter (E)",
   "meaning": "Room sensor fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e1-3"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E2",
   "also_shown_as": "",
   "model": "Window AC, Estrella Inverter (E)",
   "meaning": "Coil sensor fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e2-3"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "DF",
   "also_shown_as": "",
   "model": "Window AC, Estrella Inverter (E)",
   "meaning": "Defrost protection error",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-df-2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "EE",
   "also_shown_as": "outdoor light flashes 25",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Indoor unit EE (memory) fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-ee"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E1",
   "also_shown_as": "outdoor light flashes 26",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Indoor fan fault (marked reserved)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e1-4"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E2",
   "also_shown_as": "outdoor light flashes 27",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Indoor fan zero-crossing detection abnormal (marked reserved)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e2-4"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E3",
   "also_shown_as": "outdoor light flashes 28",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Indoor coil fault and sensor fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e3"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E4",
   "also_shown_as": "outdoor light flashes 29",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Indoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e4"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E5",
   "also_shown_as": "",
   "model": "Window AC, Estrella Inverter",
   "meaning": "No refrigerant protection (marked reserved)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e5-2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E0",
   "also_shown_as": "outdoor light flashes 1",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Outdoor unit EE (memory) fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e0"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E6",
   "also_shown_as": "outdoor light flashes 2",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Indoor and outdoor unit communication fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e6"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F1",
   "also_shown_as": "outdoor light flashes 4",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Compressor starting abnormal (phase failure, reverse)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f1"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F2",
   "also_shown_as": "outdoor light flashes 5",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Compressor out-of-step fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F3",
   "also_shown_as": "outdoor light flashes 6",
   "model": "Window AC, Estrella Inverter",
   "meaning": "IPM module fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f3"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F4",
   "also_shown_as": "outdoor light flashes 7",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Compressor shell top fault / protection (marked reserved)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f4"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F5",
   "also_shown_as": "outdoor light flashes 8",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Discharge temperature sensor fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f5"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F6",
   "also_shown_as": "outdoor light flashes 9",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Suction temperature sensor fault (marked reserved)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f6"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F7",
   "also_shown_as": "outdoor light flashes 10",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Outdoor coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f7"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F8",
   "also_shown_as": "outdoor light flashes 11",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Outdoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f8"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "F9",
   "also_shown_as": "outdoor light flashes 12",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Outdoor DC fan fault (marked reserved)",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-f9"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "E8",
   "also_shown_as": "",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Outdoor communication fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-e8"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P1",
   "also_shown_as": "outdoor light flashes 13",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Outdoor unit AC current protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p1"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P2",
   "also_shown_as": "outdoor light flashes 14",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Compressor phase current protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P3",
   "also_shown_as": "outdoor light flashes 15",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Outdoor unit AC voltage too high or too low protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p3"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P4",
   "also_shown_as": "outdoor light flashes 16",
   "model": "Window AC, Estrella Inverter",
   "meaning": "DC voltage too high or too low protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p4"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P5",
   "also_shown_as": "outdoor light flashes 17",
   "model": "Window AC, Estrella Inverter",
   "meaning": "IPM over-temperature protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p5"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P6",
   "also_shown_as": "outdoor light flashes 18",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Discharge temperature overheat protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p6"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P7",
   "also_shown_as": "outdoor light flashes 19",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Cooling: indoor coil anti-freezing protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p7"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P8",
   "also_shown_as": "outdoor light flashes 20",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Cooling: outdoor coil overheat protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p8"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "P9",
   "also_shown_as": "outdoor light flashes 21",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Heating: indoor coil overheat protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-p9"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "PC",
   "also_shown_as": "outdoor light flashes 22",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Cooling: outdoor temperature too low protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-pc"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "PH",
   "also_shown_as": "outdoor light flashes 23",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Heating: outdoor temperature too high protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-ph"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "L1",
   "also_shown_as": "outdoor light flashes 31",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Drive bus voltage too high protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-l1"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "L2",
   "also_shown_as": "outdoor light flashes 32",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Drive bus voltage too low protection",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-l2"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "L3",
   "also_shown_as": "outdoor light flashes 33",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Drive phase current overload fault",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-l3"
  },
  {
   "appliance": "ac",
   "brand": "Carrier",
   "code": "L4",
   "also_shown_as": "outdoor light flashes 34",
   "model": "Window AC, Estrella Inverter",
   "meaning": "Phase current sampling abnormal",
   "what_to_do": "",
   "source": "https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714_USER-MANUAL_XCEL_INDUS_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1030714-ACI3PR26801_USER-MANUAL_XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1033965_-USER-MANUAL-_DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACI2PR49901_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-XTREME_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/PI18PR013700_FIX-SPEED-COMBINED-MANUAL_12K-and-18K-DURAWHITE-PRO_ESTER_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/2020C1032274-R1_WRAC-ESTRELLA-FS-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/ACW5PR07501-R2_WRAC-ESTRELLA-INVERTER-MANUAL_CARRIER_2024.pdf https://carriermideaindia.com/wp-content/uploads/2024/04/USER-MANUAL_WRAC-ESTRELLA-INVERTER-E-MANUAL-_CARRIER_2024.pdf https://carriermideaindia.com/faq/",
   "checked": "2026-10-26",
   "url": "https://faultdecode.com/ac/carrier/#code-l4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ocA",
   "also_shown_as": "fault ID 1",
   "model": "MS300",
   "meaning": "Over-current during acceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oca"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ocd",
   "also_shown_as": "fault ID 2",
   "model": "MS300",
   "meaning": "Over-current during deceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ocd"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ocn",
   "also_shown_as": "fault ID 3",
   "model": "MS300",
   "meaning": "Over-current during steady operation",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ocn"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "GFF",
   "also_shown_as": "fault ID 4",
   "model": "MS300",
   "meaning": "Ground fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-gff"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ocS",
   "also_shown_as": "fault ID 6",
   "model": "MS300",
   "meaning": "Over-current at stop",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ocs"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ovA",
   "also_shown_as": "fault ID 7",
   "model": "MS300",
   "meaning": "Over-voltage during acceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ova"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ovd",
   "also_shown_as": "fault ID 8",
   "model": "MS300",
   "meaning": "Over-voltage during deceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ovd"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ovn",
   "also_shown_as": "fault ID 9",
   "model": "MS300",
   "meaning": "Over-voltage at constant speed",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ovn"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ovS",
   "also_shown_as": "fault ID 10",
   "model": "MS300",
   "meaning": "Over-voltage at stop",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ovs"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "LvA",
   "also_shown_as": "fault ID 11",
   "model": "MS300",
   "meaning": "Low-voltage during acceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-lva"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Lvd",
   "also_shown_as": "fault ID 12",
   "model": "MS300",
   "meaning": "Low-voltage during deceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-lvd"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Lvn",
   "also_shown_as": "fault ID 13",
   "model": "MS300",
   "meaning": "Low-voltage at constant speed",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-lvn"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "LvS",
   "also_shown_as": "fault ID 14",
   "model": "MS300",
   "meaning": "Low-voltage at stop",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-lvs"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "OrP",
   "also_shown_as": "fault ID 15",
   "model": "MS300",
   "meaning": "Phase loss protection",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-orp"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oH1",
   "also_shown_as": "fault ID 16",
   "model": "MS300",
   "meaning": "IGBT overheating",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oh1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "tH1o",
   "also_shown_as": "fault ID 18",
   "model": "MS300",
   "meaning": "IGBT temperature detection failure",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-th1o"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL",
   "also_shown_as": "fault ID 21",
   "model": "MS300",
   "meaning": "Over load",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EoL1",
   "also_shown_as": "fault ID 22",
   "model": "MS300",
   "meaning": "Electronic thermal relay 1 protection",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-eol1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EoL2",
   "also_shown_as": "fault ID 23",
   "model": "MS300",
   "meaning": "Electric thermal relay 2 protection",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-eol2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oH3",
   "also_shown_as": "fault ID 24",
   "model": "MS300",
   "meaning": "Motor overheating (PTC / PT100)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oh3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ot1",
   "also_shown_as": "fault ID 26",
   "model": "MS300",
   "meaning": "Over torque 1",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ot1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ot2",
   "also_shown_as": "fault ID 27",
   "model": "MS300",
   "meaning": "Over torque 2",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ot2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "uC",
   "also_shown_as": "fault ID 28",
   "model": "MS300",
   "meaning": "Under current",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-uc"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF2",
   "also_shown_as": "fault ID 31",
   "model": "MS300",
   "meaning": "EEPROM read error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cd1",
   "also_shown_as": "fault ID 33",
   "model": "MS300",
   "meaning": "U-phase error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cd1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cd2",
   "also_shown_as": "fault ID 34",
   "model": "MS300",
   "meaning": "V-phase error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cd2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cd3",
   "also_shown_as": "fault ID 35",
   "model": "MS300",
   "meaning": "W-phase error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cd3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Hd0",
   "also_shown_as": "fault ID 36",
   "model": "MS300",
   "meaning": "cc hardware failure",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hd0"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Hd1",
   "also_shown_as": "fault ID 37",
   "model": "MS300",
   "meaning": "oc hardware error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hd1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "AUE",
   "also_shown_as": "fault ID 40",
   "model": "MS300",
   "meaning": "Auto-tuning error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-aue"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "AFE",
   "also_shown_as": "fault ID 41",
   "model": "MS300",
   "meaning": "PID loss ACI",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-afe"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "PGF2",
   "also_shown_as": "fault ID 43",
   "model": "MS300",
   "meaning": "PG feedback loss",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-pgf2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "PGF3",
   "also_shown_as": "fault ID 44",
   "model": "MS300",
   "meaning": "PG feedback stall",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-pgf3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "PGF4",
   "also_shown_as": "fault ID 45",
   "model": "MS300",
   "meaning": "PG slip error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-pgf4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ACE",
   "also_shown_as": "fault ID 48",
   "model": "MS300",
   "meaning": "ACI loss",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ace"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EF",
   "also_shown_as": "fault ID 49",
   "model": "MS300",
   "meaning": "External fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ef"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EF1",
   "also_shown_as": "fault ID 50",
   "model": "MS300",
   "meaning": "Emergency stop",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ef1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "bb",
   "also_shown_as": "fault ID 51",
   "model": "MS300",
   "meaning": "External base block",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-bb"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Pcod",
   "also_shown_as": "fault ID 52",
   "model": "MS300",
   "meaning": "Password is locked",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-pcod"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CE1",
   "also_shown_as": "fault ID 54",
   "model": "MS300",
   "meaning": "Illegal command",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ce1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CE2",
   "also_shown_as": "fault ID 55",
   "model": "MS300",
   "meaning": "Illegal data address",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ce2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CE3",
   "also_shown_as": "fault ID 56",
   "model": "MS300",
   "meaning": "Illegal data value",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ce3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CE4",
   "also_shown_as": "fault ID 57",
   "model": "MS300",
   "meaning": "Data is written to read-only address",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ce4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CE10",
   "also_shown_as": "fault ID 58",
   "model": "MS300",
   "meaning": "Modbus transmission time-out",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ce10"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ydc",
   "also_shown_as": "fault ID 61",
   "model": "MS300",
   "meaning": "Y-connection / Δ-connection switch fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ydc"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "dEb",
   "also_shown_as": "fault ID 62",
   "model": "MS300",
   "meaning": "Deceleration energy backup fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-deb"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oSL",
   "also_shown_as": "fault ID 63",
   "model": "MS300",
   "meaning": "Over slip error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-osl"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "SdRv",
   "also_shown_as": "fault ID 68",
   "model": "MS300",
   "meaning": "Reverse direction of the speed feedback",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-sdrv"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "SdOr",
   "also_shown_as": "fault ID 69",
   "model": "MS300",
   "meaning": "Over speed rotation feedback",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-sdor"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "SdDe",
   "also_shown_as": "fault ID 70",
   "model": "MS300",
   "meaning": "Large deviation of speed feedback",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-sdde"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "STL1",
   "also_shown_as": "fault ID 72",
   "model": "MS300",
   "meaning": "STO loss 1",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-stl1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "STO",
   "also_shown_as": "fault ID 76",
   "model": "MS300",
   "meaning": "STO",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-sto"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "STL2",
   "also_shown_as": "fault ID 77",
   "model": "MS300",
   "meaning": "STO loss 2",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-stl2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "STL3",
   "also_shown_as": "fault ID 78",
   "model": "MS300",
   "meaning": "STO loss 3",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-stl3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Aoc",
   "also_shown_as": "fault ID 79",
   "model": "MS300",
   "meaning": "U-phase over-current before run",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-aoc"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "boc",
   "also_shown_as": "fault ID 80",
   "model": "MS300",
   "meaning": "V-phase over-current before run",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-boc"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "coc",
   "also_shown_as": "fault ID 81",
   "model": "MS300",
   "meaning": "W-phase over-current before run",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-coc"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "OPHL",
   "also_shown_as": "fault ID 82",
   "model": "MS300",
   "meaning": "Output phase loss U phase",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ophl"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "OPHL",
   "also_shown_as": "fault ID 83",
   "model": "MS300",
   "meaning": "Output phase loss V phase",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ophl-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "OPHL",
   "also_shown_as": "fault ID 84",
   "model": "MS300",
   "meaning": "Output phase loss W phase",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ophl-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL3",
   "also_shown_as": "fault ID 87",
   "model": "MS300",
   "meaning": "Overload protection at low frequency",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "RoPd",
   "also_shown_as": "fault ID 89",
   "model": "MS300",
   "meaning": "Rotor position detection error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ropd"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CGdE",
   "also_shown_as": "fault ID 101",
   "model": "MS300",
   "meaning": "CANopen guarding fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cgde"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CHbE",
   "also_shown_as": "fault ID 102",
   "model": "MS300",
   "meaning": "CANopen heartbeat fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-chbe"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CbFE",
   "also_shown_as": "fault ID 104",
   "model": "MS300",
   "meaning": "CANopen bus off fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cbfe"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CIdE",
   "also_shown_as": "fault ID 105",
   "model": "MS300",
   "meaning": "CANopen index error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cide"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CAdE",
   "also_shown_as": "fault ID 106",
   "model": "MS300",
   "meaning": "CANopen station address error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cade"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CFrE",
   "also_shown_as": "fault ID 107",
   "model": "MS300",
   "meaning": "CANopen memory error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cfre"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CP20",
   "also_shown_as": "fault ID 121",
   "model": "MS300",
   "meaning": "Internal communication error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cp20"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CP22",
   "also_shown_as": "fault ID 123",
   "model": "MS300",
   "meaning": "Internal communication error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cp22"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CP30",
   "also_shown_as": "fault ID 124",
   "model": "MS300",
   "meaning": "Internal communication error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cp30"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CP32",
   "also_shown_as": "fault ID 126",
   "model": "MS300",
   "meaning": "Internal communication error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cp32"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CP33",
   "also_shown_as": "fault ID 127",
   "model": "MS300",
   "meaning": "Internal communication error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cp33"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ot3",
   "also_shown_as": "fault ID 128",
   "model": "MS300",
   "meaning": "Over-torque 3",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ot3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ot4",
   "also_shown_as": "fault ID 129",
   "model": "MS300",
   "meaning": "Over-torque 4",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ot4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EoL3",
   "also_shown_as": "fault ID 134",
   "model": "MS300",
   "meaning": "Internal communication error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-eol3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EoL4",
   "also_shown_as": "fault ID 135",
   "model": "MS300",
   "meaning": "Internal communication error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-eol4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Hd6",
   "also_shown_as": "fault ID 140",
   "model": "MS300",
   "meaning": "oc hardware error",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hd6"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "b4GFF",
   "also_shown_as": "fault ID 141",
   "model": "MS300",
   "meaning": "GFF occurs before run",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-b4gff"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "AuE1",
   "also_shown_as": "fault ID 142",
   "model": "MS300",
   "meaning": "Auto-tune error 1",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-aue1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "AuE2",
   "also_shown_as": "fault ID 143",
   "model": "MS300",
   "meaning": "Auto-tune error 2",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-aue2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "AuE3",
   "also_shown_as": "fault ID 144",
   "model": "MS300",
   "meaning": "Auto-tune error 3",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-aue3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "AuE5",
   "also_shown_as": "fault ID 149",
   "model": "MS300",
   "meaning": "Auto-tune error 5",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-aue5"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oc",
   "also_shown_as": "fault ID 1",
   "model": "VFD-EL-W",
   "meaning": "Over-current: abnormal increase in current",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oc"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ov",
   "also_shown_as": "fault ID 2",
   "model": "VFD-EL-W",
   "meaning": "Over-voltage: DC bus voltage exceeds its maximum allowable value",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ov"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oH1",
   "also_shown_as": "fault ID 3",
   "model": "VFD-EL-W",
   "meaning": "Overheating: heat sink temperature too high",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oh1-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Lv",
   "also_shown_as": "fault ID 4",
   "model": "VFD-EL-W",
   "meaning": "Low voltage: DC bus voltage below its minimum value",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-lv"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL",
   "also_shown_as": "fault ID 5",
   "model": "VFD-EL-W",
   "meaning": "Overload: excessive drive output current (150% for 60 s max)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL1",
   "also_shown_as": "fault ID 6",
   "model": "VFD-EL-W",
   "meaning": "Overload 1: internal electronic overload trip",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL2",
   "also_shown_as": "fault ID 7",
   "model": "VFD-EL-W",
   "meaning": "Overload 2: motor overload",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EF",
   "also_shown_as": "fault ID 8",
   "model": "VFD-EL-W",
   "meaning": "External fault (MI terminal set to external fault, or address 2002H bit0 = 1)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ef-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ocA",
   "also_shown_as": "fault ID 9",
   "model": "VFD-EL-W",
   "meaning": "Over-current during acceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oca-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ocd",
   "also_shown_as": "fault ID 10",
   "model": "VFD-EL-W",
   "meaning": "Over-current during deceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ocd-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ocn",
   "also_shown_as": "fault ID 11",
   "model": "VFD-EL-W",
   "meaning": "Over-current during constant speed operation",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ocn-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "PHL",
   "also_shown_as": "fault ID 14",
   "model": "VFD-EL-W",
   "meaning": "Phase loss: check the input power is three-phase",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-phl"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cFA",
   "also_shown_as": "fault ID 16",
   "model": "VFD-EL-W",
   "meaning": "Auto acceleration / deceleration failure",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cfa"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "codE",
   "also_shown_as": "fault ID 17",
   "model": "VFD-EL-W",
   "meaning": "Software protection failure: password locked",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-code"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF1.0",
   "also_shown_as": "fault ID 18",
   "model": "VFD-EL-W",
   "meaning": "Internal EEPROM cannot be programmed (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf1-0"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF2.0",
   "also_shown_as": "fault ID 19",
   "model": "VFD-EL-W",
   "meaning": "Internal EEPROM cannot be read",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf2-0"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "HPF1",
   "also_shown_as": "fault ID 20",
   "model": "VFD-EL-W",
   "meaning": "CC (current clamp); return the unit to the factory",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hpf1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "HPF2",
   "also_shown_as": "fault ID 21",
   "model": "VFD-EL-W",
   "meaning": "OV hardware fault (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hpf2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "HPF4",
   "also_shown_as": "fault ID 23",
   "model": "VFD-EL-W",
   "meaning": "OC hardware fault (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hpf4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF3.0",
   "also_shown_as": "fault ID 24",
   "model": "VFD-EL-W",
   "meaning": "Wiring detection fault: U-phase error (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf3-0"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF3.1",
   "also_shown_as": "fault ID 25",
   "model": "VFD-EL-W",
   "meaning": "Wiring detection fault: V-phase error (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf3-1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF3.2",
   "also_shown_as": "fault ID 26",
   "model": "VFD-EL-W",
   "meaning": "Wiring detection fault: W-phase error (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf3-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF3.3",
   "also_shown_as": "fault ID 27",
   "model": "VFD-EL-W",
   "meaning": "Wiring detection fault: DC bus wiring detection error (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf3-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cF3.4",
   "also_shown_as": "fault ID 28",
   "model": "VFD-EL-W",
   "meaning": "Wiring detection fault: temperature sensor error (return to factory)",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf3-4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "AErr",
   "also_shown_as": "fault ID 32",
   "model": "VFD-EL-W",
   "meaning": "Analog signal error: check if ACI wiring is broken",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-aerr"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "PTC1",
   "also_shown_as": "fault ID 34",
   "model": "VFD-EL-W",
   "meaning": "Motor internal temperature too high (PTC); motor coasts to stop",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ptc1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "FbE",
   "also_shown_as": "fault ID 35",
   "model": "VFD-EL-W",
   "meaning": "PID feedback signal fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-fbe"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "dEv",
   "also_shown_as": "fault ID 36",
   "model": "VFD-EL-W",
   "meaning": "Unusual PID feedback",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-dev"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oPHL",
   "also_shown_as": "fault ID 37",
   "model": "VFD-EL-W",
   "meaning": "Multi-motor fault protection: check motor wiring",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ophl-4"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "HotP",
   "also_shown_as": "fault ID 38",
   "model": "VFD-EL-W",
   "meaning": "Thermal cutout triggered",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hotp"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "bb",
   "also_shown_as": "",
   "model": "VFD-EL-W",
   "meaning": "External base block: drive stops output while B.B. input is active",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-bb-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cE--",
   "also_shown_as": "",
   "model": "VFD-EL-W",
   "meaning": "Communication fault: check RJ45 wiring and protocol settings",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ce"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oc",
   "also_shown_as": "Pr.73 record 01",
   "model": "VFD-M",
   "meaning": "Over-current",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oc-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "ov",
   "also_shown_as": "Pr.73 record 02",
   "model": "VFD-M",
   "meaning": "Over-voltage",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ov-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oH",
   "also_shown_as": "Pr.73 record 03",
   "model": "VFD-M",
   "meaning": "Overheat",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oh"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL",
   "also_shown_as": "Pr.73 record 04",
   "model": "VFD-M",
   "meaning": "Overload",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL1",
   "also_shown_as": "Pr.73 record 05",
   "model": "VFD-M",
   "meaning": "Overload 1",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol1-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "EF",
   "also_shown_as": "Pr.73 record 06",
   "model": "VFD-M",
   "meaning": "External fault",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ef-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CF1",
   "also_shown_as": "Pr.73 record 07",
   "model": "VFD-M",
   "meaning": "CPU failure 1",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf1"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CF3",
   "also_shown_as": "Pr.73 record 08",
   "model": "VFD-M",
   "meaning": "CPU failure 3",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "HPF",
   "also_shown_as": "Pr.73 record 09",
   "model": "VFD-M",
   "meaning": "Hardware protection failure",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-hpf"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "OCA",
   "also_shown_as": "Pr.73 record 10",
   "model": "VFD-M",
   "meaning": "Over-current during acceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-oca-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "OCd",
   "also_shown_as": "Pr.73 record 11",
   "model": "VFD-M",
   "meaning": "Over-current during deceleration",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ocd-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "OCn",
   "also_shown_as": "Pr.73 record 12",
   "model": "VFD-M",
   "meaning": "Over-current during steady state operation",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ocn-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "GFF",
   "also_shown_as": "Pr.73 record 13",
   "model": "VFD-M",
   "meaning": "Ground fault or fuse failure",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-gff-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "CF2",
   "also_shown_as": "Pr.73 record 16",
   "model": "VFD-M",
   "meaning": "CPU failure",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cf2-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "bb",
   "also_shown_as": "Pr.73 record 17",
   "model": "VFD-M",
   "meaning": "External base block",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-bb-3"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "oL2",
   "also_shown_as": "Pr.73 record 18",
   "model": "VFD-M",
   "meaning": "Overload 2",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-ol2-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "cFA",
   "also_shown_as": "Pr.73 record 19",
   "model": "VFD-M",
   "meaning": "Auto adjustable accel/decel failure",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-cfa-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "codE",
   "also_shown_as": "Pr.73 record 20",
   "model": "VFD-M",
   "meaning": "Software protection code",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-code-2"
  },
  {
   "appliance": "vfd",
   "brand": "Delta",
   "code": "Lv",
   "also_shown_as": "Pr.73 record 14 (not recorded)",
   "model": "VFD-M",
   "meaning": "Low voltage",
   "what_to_do": "",
   "source": "https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=8016&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=19555&docPath=1 https://www.deltaww.com/en-US/service-support/download-center/terms-of-use/verify?did=1209&docPath=1 https://www.deltaww.com/en-US/service-support/download-center?sectionId=2",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/vfd/delta/#code-lv-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E1",
   "also_shown_as": "indoor unit",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Room sensor short or open",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e1"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E2",
   "also_shown_as": "indoor unit",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor coil sensor short or open",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "dF",
   "also_shown_as": "indoor unit",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor defrost protection error in cool and dry mode",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-df"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E5",
   "also_shown_as": "indoor unit",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Fan motor error",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e5"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E6",
   "also_shown_as": "indoor unit",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Zero crossing error",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e6"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "EC",
   "also_shown_as": "selected models only",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Gas leak detection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-ec"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "HP",
   "also_shown_as": "heat mode",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor coil high temperature protection in heat mode",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-hp"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E3",
   "also_shown_as": "outdoor unit",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Outdoor coil sensor short or open",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "HF",
   "also_shown_as": "outdoor unit, heat mode",
   "model": "Split AC, \"conventional series\" table (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Outdoor defrost protection error in heat mode",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-hf"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "EE",
   "also_shown_as": "",
   "model": "Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor machine EE fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-ee"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E1",
   "also_shown_as": "",
   "model": "Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor fan fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e1-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E2",
   "also_shown_as": "",
   "model": "Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor fan zero-crossing detection abnormal",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e2-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E3",
   "also_shown_as": "",
   "model": "Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor coil fault and sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e3-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E4",
   "also_shown_as": "",
   "model": "Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Indoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e4"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E9",
   "also_shown_as": "test mode only",
   "model": "Split AC, Wi-Fi error code list (SAC 123 Vectra Elegant, SAC 125V DZX manuals)",
   "meaning": "Wi-Fi module fault (seen while pressing the emergency switch and powering on the indoor unit)",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e9"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E1",
   "also_shown_as": "",
   "model": "Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter)",
   "meaning": "Room sensor short or open",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e1-3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E2",
   "also_shown_as": "",
   "model": "Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter)",
   "meaning": "Coil sensor short or open",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e2-3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E3",
   "also_shown_as": "heat mode",
   "model": "Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter)",
   "meaning": "Condenser coil sensor short or open in heat mode",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e3-3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "HF",
   "also_shown_as": "heat mode",
   "model": "Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter)",
   "meaning": "Condenser coil defrost in heat mode",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-hf-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "dF",
   "also_shown_as": "cool and dry mode",
   "model": "Window AC (WAC 173 DZA, WAC 093 Vectra Platina; not the WAC 183V ADI inverter)",
   "meaning": "Defrost; occurs in cool mode and dry mode",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-df-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "EE",
   "also_shown_as": "outdoor light flashes 25",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Indoor machine EE fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-ee-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E1",
   "also_shown_as": "outdoor light flashes 26",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Indoor fan fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e1-4"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E2",
   "also_shown_as": "outdoor light flashes 27",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Indoor fan zero-crossing detection abnormal",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e2-4"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E3",
   "also_shown_as": "outdoor light flashes 28",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Indoor coil fault and sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e3-4"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E4",
   "also_shown_as": "outdoor light flashes 29",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Indoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e4-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E0",
   "also_shown_as": "outdoor light flashes 1",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Outdoor EE fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e0"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F1",
   "also_shown_as": "outdoor light flashes 4",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Compressor starting abnormal (phase failure, reverse)",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f1"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F2",
   "also_shown_as": "outdoor light flashes 5",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Compressor out-of-step fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F3",
   "also_shown_as": "outdoor light flashes 6",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "IPM module fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F4",
   "also_shown_as": "outdoor light flashes 7",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Compressor shell roof fault / protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f4"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F5",
   "also_shown_as": "outdoor light flashes 8",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Discharge temperature sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f5"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F6",
   "also_shown_as": "outdoor light flashes 9",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Suction temperature sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f6"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F7",
   "also_shown_as": "outdoor light flashes 10",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Outdoor coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f7"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F8",
   "also_shown_as": "outdoor light flashes 11",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Outdoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f8"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "F9",
   "also_shown_as": "outdoor light flashes 12",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Outdoor DC fan fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-f9"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P1",
   "also_shown_as": "outdoor light flashes 13",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Outdoor machine AC current protection (WAC 183V ADI table: AC current / power overload protection)",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p1"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P2",
   "also_shown_as": "outdoor light flashes 14",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Compressor phase current protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P3",
   "also_shown_as": "outdoor light flashes 15",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Outdoor unit AC voltage too high or too low protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P4",
   "also_shown_as": "outdoor light flashes 16",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "DC voltage too high or too low protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p4"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P5",
   "also_shown_as": "outdoor light flashes 17",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "IPM over-high temperature protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p5"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P6",
   "also_shown_as": "outdoor light flashes 18",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Discharge temperature overheat protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p6"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P7",
   "also_shown_as": "outdoor light flashes 19",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Cooling: indoor coil anti-freezing protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p7"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P8",
   "also_shown_as": "outdoor light flashes 20",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Cooling: outdoor coil overheat protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p8"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "P9",
   "also_shown_as": "outdoor light flashes 21",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Heating: indoor coil overheat protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-p9"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "PC",
   "also_shown_as": "outdoor light flashes 22",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Cooling: outdoor ambient temperature too low protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-pc"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "PH",
   "also_shown_as": "outdoor light flashes 23",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Heating: outdoor ambient temperature too high protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-ph"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "L1",
   "also_shown_as": "outdoor light flashes 31",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Drive bus voltage too high protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-l1"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "L2",
   "also_shown_as": "outdoor light flashes 32",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Drive bus voltage too low protection",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-l2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "L3",
   "also_shown_as": "outdoor light flashes 33",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Drive phase current overload fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-l3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "L4",
   "also_shown_as": "outdoor light flashes 34",
   "model": "Inverter AC (SAC 183V WZJ split, WAC 183V ADI window)",
   "meaning": "Phase current sampling abnormal",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-l4"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E6",
   "also_shown_as": "outdoor light flashes 2",
   "model": "Inverter split AC, SAC 183V WZJ",
   "meaning": "Indoor and outdoor machine communication fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e6-2"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E6",
   "also_shown_as": "outdoor light flashes 2",
   "model": "Inverter window AC, WAC 183V ADI",
   "meaning": "Main board and drive board communication fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e6-3"
  },
  {
   "appliance": "ac",
   "brand": "Voltas",
   "code": "E8",
   "also_shown_as": "no outdoor flash count",
   "model": "Inverter split AC, SAC 183V WZJ only",
   "meaning": "Outdoor communication fault",
   "what_to_do": "",
   "source": "https://vcareapi.voltasworld.com/dms/file?id=8aa8c777079aa15736dcf9a244794e1a https://vcareapi.voltasworld.com/dms/file?id=1051d55eb0343bdfca1ba185865952db https://vcareapi.voltasworld.com/dms/file?id=a3b0670624f4e5ff549d5970cae88489 https://vcareapi.voltasworld.com/dms/file?id=7aa1b7534599e77a1d7ca0e7a56f1e58 https://vcareapi.voltasworld.com/dms/file?id=79372326257fedcc0e439ea94ca15a5f https://vcareapi.voltasworld.com/dms/file?id=32d82f623587e6d951a2ff7b6ec6f9ec https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://voltasservice.com/ https://vcareapi.voltasworld.com/dms/file?id=21bcd302a0ae2908bb532b5af10330d9 https://vcareapi.voltasworld.com/dms/file?id=02dc775d8d23122d938cf309d4457b8b https://vcareapi.voltasworld.com/dms/file?id=0a835e0a0cba4bc8bb57e58a66390dfd https://vcareapi.voltasworld.com/dms/file?id=06f1c4a21a316d07ae317a3b6df64722 https://vcareapi.voltasworld.com/dms/file?id=6815993c9f2bb5a912527c3694eb1186 https://vcareapi.voltasworld.com/dms/file?id=63ddc1dc48e1a3ef19575fe1b494887c https://vcareapi.voltasworld.com/dms/file?id=3d20584b5a7052e96755add189506438 https://vcareapi.voltasworld.com/dms/file?id=de0a52f19b8a9c471d02a1310e2300e7 https://vcareapi.voltasworld.com/dms/file?id=0df1fca11ac08ceaf6ed3c2eb3338740 https://vcareapi.voltasworld.com/dms/file?id=0b7fa4046ad0ecbb41aaf026a1293bb6 https://vcareapi.voltasworld.com/dms/file?id=b73ed0500ed040b185f150df159f2aa4 https://vcareapi.voltasworld.com/dms/file?id=3437ec3710efe13bf30188423280feb0",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/voltas/#code-e8"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "E30",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB, GLWF804TSGGB)",
   "meaning": "Door is not closed properly",
   "what_to_do": "Close the door properly and restart.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-e30"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "E10",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB, GLWF804TSGGB)",
   "meaning": "Water injecting problem during wash cycle",
   "what_to_do": "Check the water pressure is high enough, straighten the water pipe, clean the inlet valve filter.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-e10"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "E21",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB, GLWF804TSGGB)",
   "meaning": "Overtime water draining",
   "what_to_do": "Check the drain hose for blockage.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-e21"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "E12",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB, GLWF804TSGGB)",
   "meaning": "Water overflow",
   "what_to_do": "Restart the appliance. If the problem persists, contact Lloyd customer service.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-e12"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "EXX",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB, GLWF804TSGGB)",
   "meaning": "Others (any other E code)",
   "what_to_do": "Restart the appliance. If the problem persists, contact customer service.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-exx"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "CL",
   "also_shown_as": "alternates with the remaining time, or with End",
   "model": "Front load (GLWF703TSGGB)",
   "meaning": "Child Lock is on (not a fault). Pressing any other button makes the Child Lock indicator flash",
   "what_to_do": "To switch Child Lock off, press Function and Boost together: only these two buttons pressed together can deactivate it. Lloyd says to switch Child Lock off before selecting a new programme.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-cl"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "End",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB)",
   "meaning": "The wash programme has finished (with a buzzer beep). Not a fault",
   "what_to_do": "Nothing to fix. The programme is over.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-end"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "t19",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB)",
   "meaning": "Calibration started (not a fault). Shown after switching on and pressing Temp. and Boost together for about 10 seconds, with all accessories removed from the drum and the door closed",
   "what_to_do": "Press Start/Pause and wait until ---- is displayed. Lloyd recommends calibrating the machine for best performance.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-t19"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "----",
   "also_shown_as": "",
   "model": "Front load (GLWF703TSGGB)",
   "meaning": "Shown at the end of the t19 calibration run (Lloyd: press Start/Pause and wait till ---- is displayed)",
   "what_to_do": "Nothing to fix.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-dashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "E1",
   "also_shown_as": "",
   "model": "Semi-automatic with heater (GLWS905GH1 series)",
   "meaning": "Low water level / no water",
   "what_to_do": "Fill sufficient water above the low water level mark and it will disappear.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-e1"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "E3",
   "also_shown_as": "",
   "model": "Semi-automatic with heater (GLWS905GH1 series)",
   "meaning": "Door (lid) open",
   "what_to_do": "Close the lid properly (wash or spin side, as per the side the error shows on).",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-e3"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "F4",
   "also_shown_as": "",
   "model": "Semi-automatic with heater (GLWS905GH1 series)",
   "meaning": "Heater malfunction",
   "what_to_do": "Call the Lloyd service centre.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-f4"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "F5",
   "also_shown_as": "",
   "model": "Semi-automatic with heater (GLWS905GH1 series)",
   "meaning": "Water level sensor failure",
   "what_to_do": "Call the Lloyd service centre.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-f5"
  },
  {
   "appliance": "washing-machine",
   "brand": "Lloyd",
   "code": "F8",
   "also_shown_as": "",
   "model": "Semi-automatic with heater (GLWS905GH1 series)",
   "meaning": "Temperature sensor error",
   "what_to_do": "Call the Lloyd service centre.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual_Washing_Machine.pdf https://havells.com/media/wysiwyg/Manuals/Lloyd_Users_Manual.pdf https://havells.com/media/wysiwyg/Manuals/User_Manual_Semi_Automatic_Washing_Machine.pdf https://havells.com/havells_studio/manuals-documents",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/lloyd/#code-f8"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "E1",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor temperature sensor failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-e1"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "E2",
   "also_shown_as": "",
   "model": "",
   "meaning": "Pipe temperature sensor failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-e2"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "E4",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor EEPROM failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-e4"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "E5",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor anti-frosting protection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-e5"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "E7",
   "also_shown_as": "",
   "model": "",
   "meaning": "Communication fault between indoor and outdoor units",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-e7"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "E9",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor unit overload in heating mode",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-e9"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "E14",
   "also_shown_as": "",
   "model": "",
   "meaning": "Indoor fan motor malfunction",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-e14"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F1",
   "also_shown_as": "",
   "model": "",
   "meaning": "IPM protection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f1"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F2",
   "also_shown_as": "",
   "model": "",
   "meaning": "Instantaneous over-current protection of the compressor",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f2"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F3",
   "also_shown_as": "",
   "model": "",
   "meaning": "Communication error between power module and main PCB board",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f3"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F4",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor discharging temperature protection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f4"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F6",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor ambient sensor failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f6"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F7",
   "also_shown_as": "",
   "model": "",
   "meaning": "Suction temperature sensor failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f7"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F8",
   "also_shown_as": "",
   "model": "",
   "meaning": "DC fan motor malfunction",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f8"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F9",
   "also_shown_as": "",
   "model": "",
   "meaning": "Module reset",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f9"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F11",
   "also_shown_as": "",
   "model": "",
   "meaning": "Loss of synchronism detection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f11"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F12",
   "also_shown_as": "",
   "model": "",
   "meaning": "EEPROM failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f12"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F13",
   "also_shown_as": "",
   "model": "",
   "meaning": "Lack of refrigerant",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f13"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F14",
   "also_shown_as": "",
   "model": "",
   "meaning": "4-way valve reverse failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f14"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F19",
   "also_shown_as": "",
   "model": "",
   "meaning": "Power over/under voltage protection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f19"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F20",
   "also_shown_as": "",
   "model": "",
   "meaning": "High pressure protection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f20"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F21",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor coil temperature sensor",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f21"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F22",
   "also_shown_as": "",
   "model": "",
   "meaning": "Outdoor alternating current over-current protection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f22"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F23",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor U-phase, V-phase or W-phase overcurrent",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f23"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F24",
   "also_shown_as": "",
   "model": "",
   "meaning": "CT detection current abnormal protection",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f24"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F25",
   "also_shown_as": "",
   "model": "",
   "meaning": "Abnormal compressor discharge sensor",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f25"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F27",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor current sampling circuit fault",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f27"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F28",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor position detection circuit fault",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f28"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F35",
   "also_shown_as": "",
   "model": "",
   "meaning": "Compressor driver board failure",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f35"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "F43",
   "also_shown_as": "",
   "model": "",
   "meaning": "Model matching abnormality",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-f43"
  },
  {
   "appliance": "ac",
   "brand": "Haier",
   "code": "FE",
   "also_shown_as": "",
   "model": "",
   "meaning": "Fixed frequency AC: refrigerant leaking detection malfunction",
   "what_to_do": "",
   "source": "https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/ac/haier/#code-fe"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OUt1",
   "also_shown_as": "fault type 1",
   "model": "GD100-PV",
   "meaning": "Inverter unit U-phase protection",
   "what_to_do": "Acceleration too fast, IGBT module damaged, interference, poor drive wire connection, or a short to ground. INVT: increase ACC time, check drive wires and interference; replace the power unit if damaged.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-out1"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OUt2",
   "also_shown_as": "fault type 2",
   "model": "GD100-PV",
   "meaning": "Inverter unit V-phase protection",
   "what_to_do": "Same causes and fixes as OUt1.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-out2"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OUt3",
   "also_shown_as": "fault type 3",
   "model": "GD100-PV",
   "meaning": "Inverter unit W-phase protection",
   "what_to_do": "Same causes and fixes as OUt1.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-out3"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OV1",
   "also_shown_as": "fault type 7",
   "model": "GD100-PV",
   "meaning": "Overvoltage during acceleration",
   "what_to_do": "Input voltage abnormal, large energy feedback, no braking components, or dynamic brake disabled (INVT gives the same causes for OV1, OV2 and OV3). INVT: check the input power, check whether the DEC time is too short or the inverter starts while the motor is turning, install braking components, check related settings.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ov1"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OV2",
   "also_shown_as": "fault type 8",
   "model": "GD100-PV",
   "meaning": "Overvoltage during deceleration",
   "what_to_do": "Same causes and fixes as OV1.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ov2"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OV3",
   "also_shown_as": "fault type 9",
   "model": "GD100-PV",
   "meaning": "Overvoltage during constant speed running",
   "what_to_do": "Same causes and fixes as OV1.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ov3"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OC1",
   "also_shown_as": "fault type 4",
   "model": "GD100-PV",
   "meaning": "Overcurrent during acceleration",
   "what_to_do": "Acceleration or deceleration too fast, low grid voltage, inverter power too low, abnormal load, short to ground or output phase loss, strong interference, or overvoltage stall protection disabled.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-oc1"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OC2",
   "also_shown_as": "fault type 5",
   "model": "GD100-PV",
   "meaning": "Overcurrent during deceleration",
   "what_to_do": "Same causes as OC1.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-oc2"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OC3",
   "also_shown_as": "fault type 6",
   "model": "GD100-PV",
   "meaning": "Overcurrent during constant speed running",
   "what_to_do": "Same causes as OC1.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-oc3"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "UV",
   "also_shown_as": "fault type 10",
   "model": "GD100-PV",
   "meaning": "Bus undervoltage",
   "what_to_do": "Grid voltage too low or overvoltage stall protection disabled. INVT: check the grid input power and related settings.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-uv"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OL1",
   "also_shown_as": "fault type 11",
   "model": "GD100-PV",
   "meaning": "Motor overload",
   "what_to_do": "Grid voltage too low, motor rated current set wrong, or motor stall or sudden load change. INVT: check the grid voltage, reset the motor rated current, check the load and adjust torque boost.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ol1"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OL2",
   "also_shown_as": "fault type 12",
   "model": "GD100-PV",
   "meaning": "Inverter overload",
   "what_to_do": "Acceleration too fast, a rotating motor was reset, grid voltage too low, load too heavy, or motor power too small. INVT: increase ACC time, avoid restarting right after a stop, check the grid voltage, select a larger inverter or a proper motor.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ol2"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "SPI",
   "also_shown_as": "fault type 13",
   "model": "GD100-PV",
   "meaning": "Phase loss on the input side",
   "what_to_do": "Phase loss or violent fluctuation on input R, S, T. INVT: check input power and installation wiring.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-spi"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "SPO",
   "also_shown_as": "fault type 14",
   "model": "GD100-PV",
   "meaning": "Phase loss on the output side",
   "what_to_do": "Phase loss on U, V, W, or the three load phases are seriously unequal. INVT: check output wiring, motor and cable.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-spo"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OH1",
   "also_shown_as": "fault type 15",
   "model": "GD100-PV",
   "meaning": "Rectifier module overheating (P07 list: boost module overheat)",
   "what_to_do": "Air duct blocked or fan damaged, ambient temperature too high, or overload for too long.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-oh1"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OH2",
   "also_shown_as": "fault type 16",
   "model": "GD100-PV",
   "meaning": "Inverter module overheat",
   "what_to_do": "Same causes as OH1. INVT: clear the vent duct or replace the fan, lower the ambient temperature.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-oh2"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "EF",
   "also_shown_as": "fault type 17",
   "model": "GD100-PV",
   "meaning": "External fault",
   "what_to_do": "An external fault input terminal (SI) acted. INVT: check the external device input.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ef"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "CE",
   "also_shown_as": "fault type 18",
   "model": "GD100-PV",
   "meaning": "RS485 communication fault",
   "what_to_do": "Wrong baud rate or address, wiring fault, or strong interference.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ce"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "ItE",
   "also_shown_as": "fault type 19",
   "model": "GD100-PV",
   "meaning": "Current detection fault",
   "what_to_do": "Control board connector loose, Hall device damaged, or amplifier circuit fault.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ite"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "tE",
   "also_shown_as": "fault type 20",
   "model": "GD100-PV",
   "meaning": "Motor autotuning fault",
   "what_to_do": "Motor capacity does not match, motor parameters set wrong, autotuned values far from standard, or autotuning timed out.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-te"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "EEP",
   "also_shown_as": "fault type 21",
   "model": "GD100-PV",
   "meaning": "EEPROM operation fault",
   "what_to_do": "Error reading or writing control parameters, or EEPROM damaged. INVT: press STOP/RST; change the main control board if it stays.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-eep"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "PIDE",
   "also_shown_as": "fault type 22",
   "model": "GD100-PV",
   "meaning": "PID feedback disconnection",
   "what_to_do": "PID feedback signal wire disconnected or the feedback source is gone.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-pide"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "bCE",
   "also_shown_as": "fault type 23",
   "model": "GD100-PV",
   "meaning": "Braking unit fault",
   "what_to_do": "Listed in the fault record (P07.27) only; no cause given in the fault table.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-bce"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "END",
   "also_shown_as": "fault type 24",
   "model": "GD100-PV",
   "meaning": "Running time reached",
   "what_to_do": "The inverter has run longer than its internal set running time. INVT: ask the supplier to adjust the preset running time.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-end"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OL3",
   "also_shown_as": "fault type 25",
   "model": "GD100-PV",
   "meaning": "Electronic overload",
   "what_to_do": "Overload pre-alarm reached the set threshold. INVT: check the load and the overload pre-alarm threshold.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ol3"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "ETH1",
   "also_shown_as": "fault type 32",
   "model": "GD100-PV",
   "meaning": "To-ground short-circuit fault 1",
   "what_to_do": "Inverter output is shorted to ground. INVT: check the motor wiring.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-eth1"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "ETH2",
   "also_shown_as": "fault type 33",
   "model": "GD100-PV",
   "meaning": "To-ground short-circuit fault 2",
   "what_to_do": "Fault in the current detection circuit. INVT: replace the Hall device or change the main control board.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-eth2"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "dEu",
   "also_shown_as": "fault type 34",
   "model": "GD100-PV",
   "meaning": "Speed deviation fault",
   "what_to_do": "Load too heavy or stalled.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-deu"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "STo",
   "also_shown_as": "fault type 35",
   "model": "GD100-PV",
   "meaning": "Mal-adjustment fault",
   "what_to_do": "SM control parameters wrong, autotuned parameters not accurate, or the inverter is not connected to the motor.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-sto"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "LL",
   "also_shown_as": "fault type 36",
   "model": "GD100-PV",
   "meaning": "Electronic underload",
   "what_to_do": "Underload pre-alarm reached the set threshold. INVT: check the load and the underload pre-alarm threshold.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ll"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "tSF",
   "also_shown_as": "fault type 37",
   "model": "GD100-PV",
   "meaning": "Hydraulic probe damage",
   "what_to_do": "The hydraulic (water level) probe is damaged. INVT: replace the probe.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-tsf"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "PINV",
   "also_shown_as": "fault type 38",
   "model": "GD100-PV",
   "meaning": "PV reverse connection fault",
   "what_to_do": "Solar panel (PV) wiring is reversed. INVT: swap the positive and negative wiring and wire it again.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-pinv"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "PVOC",
   "also_shown_as": "fault type 39",
   "model": "GD100-PV",
   "meaning": "PV overcurrent",
   "what_to_do": "ACC or DEC too fast, inverter power too low, abnormal load, or short to ground.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-pvoc"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "PVOV",
   "also_shown_as": "fault type 40",
   "model": "GD100-PV",
   "meaning": "PV overvoltage",
   "what_to_do": "Solar panel input voltage too high, or model -4 set as another model.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-pvov"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "PVLV",
   "also_shown_as": "fault type 41",
   "model": "GD100-PV",
   "meaning": "PV undervoltage",
   "what_to_do": "Too little panel power in series, cloudy or rainy weather, or motor starting current too high.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-pvlv"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "E-422",
   "also_shown_as": "fault type 42",
   "model": "GD100-PV",
   "meaning": "Fault on 422 communication with the boost module",
   "what_to_do": "The four 422 communication cables are in poor contact.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-e-422"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "OV",
   "also_shown_as": "fault type 43 (boost side)",
   "model": "GD100-PV",
   "meaning": "Bus overvoltage detected on the boost side",
   "what_to_do": "Sunlight changes sharply. INVT: adjust the boost PI parameters and increase P19.07 and P19.08.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-ov"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "A-LS",
   "also_shown_as": "alarm",
   "model": "GD100-PV",
   "meaning": "Weak-light pre-alarm (not a fault)",
   "what_to_do": "Sunlight is weak or the panel setup is too small. The pump sleeps and restarts by itself when light is enough.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-a-ls"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "A-LL",
   "also_shown_as": "alarm",
   "model": "GD100-PV",
   "meaning": "Underload pre-alarm (not a fault)",
   "what_to_do": "The pumping pool (well or tank) has no water. INVT: check the pumping pool.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-a-ll"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "A-tF",
   "also_shown_as": "alarm",
   "model": "GD100-PV",
   "meaning": "Full-water pre-alarm (not a fault)",
   "what_to_do": "The pool or tank is full. With the full-water function set up, the pump stops after a delay; otherwise check the level terminal wiring.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-a-tf"
  },
  {
   "appliance": "solar-pump",
   "brand": "INVT",
   "code": "A-tL",
   "also_shown_as": "alarm",
   "model": "GD100-PV",
   "meaning": "Empty-water pre-alarm (not a fault)",
   "what_to_do": "The pool has no water. With the empty-water function set up, the pump stops after a delay; otherwise check the level terminal wiring.",
   "source": "https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf",
   "checked": "2026-10-27",
   "url": "https://faultdecode.com/solar-pump/invt/#code-a-tl"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "EE",
   "also_shown_as": "outdoor 25 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor unit EE fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-ee"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E1",
   "also_shown_as": "outdoor 26 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor fan fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e1"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E2",
   "also_shown_as": "outdoor 27 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor fan zero-crossing detection fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E3",
   "also_shown_as": "outdoor 28 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e3"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E4",
   "also_shown_as": "outdoor 29 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e4"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E0",
   "also_shown_as": "outdoor 1 flash",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor unit EE fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e0"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E6",
   "also_shown_as": "outdoor 2 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor and outdoor unit communication fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e6"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F1",
   "also_shown_as": "outdoor 4 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Compressor starting abnormal",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f1"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F2",
   "also_shown_as": "outdoor 5 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Compressor drive fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F3",
   "also_shown_as": "outdoor 6 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "IPM module fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f3"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F4",
   "also_shown_as": "outdoor 7 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Compressor shell top fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f4"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F5",
   "also_shown_as": "outdoor 8 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Discharge temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f5"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F6",
   "also_shown_as": "outdoor 9 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Suction temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f6"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F7",
   "also_shown_as": "outdoor 10 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f7"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F8",
   "also_shown_as": "outdoor 11 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f8"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F9",
   "also_shown_as": "outdoor 12 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor DC fan fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f9"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P1",
   "also_shown_as": "outdoor 13 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor unit AC current protection",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p1"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P2",
   "also_shown_as": "outdoor 14 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Compressor phase current protection",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P3",
   "also_shown_as": "outdoor 15 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor unit AC voltage too high or too low (protection)",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p3"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P4",
   "also_shown_as": "outdoor 16 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "DC overvoltage or undervoltage protection",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p4"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P5",
   "also_shown_as": "outdoor 17 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "IPM overheat protection",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p5"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P6",
   "also_shown_as": "outdoor 18 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Discharge temperature overheat protection",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p6"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P7",
   "also_shown_as": "outdoor 19 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor coil anti-freezing protection in cooling",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p7"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P8",
   "also_shown_as": "outdoor 20 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor coil overheat protection in cooling",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p8"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P9",
   "also_shown_as": "outdoor 21 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Indoor coil overheat protection in heating",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p9"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "PC",
   "also_shown_as": "outdoor 22 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor temperature too low for cooling (protection)",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-pc"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "PH",
   "also_shown_as": "outdoor 23 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Outdoor temperature too high for heating (protection)",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-ph"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "L1",
   "also_shown_as": "outdoor 31 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Drive bus voltage too high (protection)",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-l1"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "L2",
   "also_shown_as": "outdoor 32 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Drive bus voltage too low (protection)",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-l2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "L3",
   "also_shown_as": "outdoor 33 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Drive phase current overload fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-l3"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "L4",
   "also_shown_as": "outdoor 34 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Phase current sampling abnormal",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-l4"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "FC",
   "also_shown_as": "outdoor 35 flashes",
   "model": "Inverter (2026 manual, selected models)",
   "meaning": "Filter clean reminder (not a fault). Onida: press SLEEP 4 times within 8 seconds to reset",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-fc"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "EB",
   "also_shown_as": "",
   "model": "Inverter (All Models manual)",
   "meaning": "Outdoor communication fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-eb"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "F2",
   "also_shown_as": "",
   "model": "Inverter (All Models manual)",
   "meaning": "Compressor out-of-step fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-f2-2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "EE",
   "also_shown_as": "",
   "model": "Fixed speed (2026 manual)",
   "meaning": "Indoor unit EE fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-ee-2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E1",
   "also_shown_as": "",
   "model": "Fixed speed (2026 manual)",
   "meaning": "Indoor fan fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e1-2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E3",
   "also_shown_as": "",
   "model": "Fixed speed (2026 manual)",
   "meaning": "Indoor coil temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e3-2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E4",
   "also_shown_as": "",
   "model": "Fixed speed (2026 manual)",
   "meaning": "Indoor ambient temperature sensor fault",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e4-2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "P7",
   "also_shown_as": "",
   "model": "Fixed speed (2026 manual)",
   "meaning": "Indoor coil anti-freezing protection in cooling",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-p7-2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E1",
   "also_shown_as": "alternates with set temperature every 4 seconds",
   "model": "Fixed speed (All Models manual)",
   "meaning": "Room sensor short or open",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e1-3"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E2",
   "also_shown_as": "alternates with set temperature every 4 seconds",
   "model": "Fixed speed (All Models manual)",
   "meaning": "Coil sensor short or open",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e2-2"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "E5/H6",
   "also_shown_as": "",
   "model": "Fixed speed (All Models manual)",
   "meaning": "Fan motor error",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-e5-h6"
  },
  {
   "appliance": "ac",
   "brand": "Onida",
   "code": "dF",
   "also_shown_as": "",
   "model": "Fixed speed (All Models manual)",
   "meaning": "Defrost error",
   "what_to_do": "",
   "source": "https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/onida/#code-df"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "1 flash",
   "also_shown_as": "upper operation lamp, every 0.5 s",
   "model": "FAQ flash table",
   "meaning": "Room temperature thermistor short or open circuit",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-1-flash"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "2 flashes",
   "also_shown_as": "upper operation lamp, then 2.5 s off",
   "model": "FAQ flash table",
   "meaning": "Indoor coil thermistor short or open circuit",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-2-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "3 flashes",
   "also_shown_as": "upper operation lamp, then 2.5 s off",
   "model": "FAQ flash table",
   "meaning": "Serial signal (Mitsubishi lists the condition as no fan speed feedback signal during indoor fan operation)",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-3-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "4 flashes",
   "also_shown_as": "upper operation lamp",
   "model": "Inverter only (FAQ flash table)",
   "meaning": "Indoor fan motor (Mitsubishi lists the condition as indoor PCB failure)",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-4-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "5 flashes",
   "also_shown_as": "upper operation lamp",
   "model": "Inverter only (FAQ flash table)",
   "meaning": "Indoor control system: compressor stopped after 3 over-current or start-up failure protections within 1 minute of start-up",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-5-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "6 flashes",
   "also_shown_as": "upper operation lamp",
   "model": "Inverter only (FAQ flash table)",
   "meaning": "Outdoor thermistor short or open circuit",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-6-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "7 flashes",
   "also_shown_as": "upper operation lamp",
   "model": "Inverter only (FAQ flash table)",
   "meaning": "Outdoor control system: indoor or outdoor PCB failure",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-7-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "11 flashes",
   "also_shown_as": "upper operation lamp",
   "model": "FAQ flash table",
   "meaning": "Indoor fan motor: no fan speed feedback signal for 12 seconds of indoor fan operation",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-11-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "14 flashes",
   "also_shown_as": "upper operation lamp",
   "model": "FAQ flash table",
   "meaning": "Refrigerant circuit: unit pumped down for a long time, low refrigerant, short cycling, or outdoor fan motor locked",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-14-flashes"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "00",
   "also_shown_as": "remote CHECK display",
   "model": "Indoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "No error (normal)",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-00"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "E6/E7",
   "also_shown_as": "remote CHECK display",
   "model": "Indoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Serial signal (abnormal point; read with the remote CHECK button)",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-e6-e7"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "Fb",
   "also_shown_as": "remote CHECK display",
   "model": "Indoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Indoor control system",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-fb"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "P1",
   "also_shown_as": "remote CHECK display",
   "model": "Indoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Room temperature thermistor",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-p1"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "P2/P9",
   "also_shown_as": "remote CHECK display",
   "model": "Indoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Indoor coil thermistor",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-p2-p9"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "Pb",
   "also_shown_as": "remote CHECK display",
   "model": "Indoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Indoor fan motor",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-pb"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "E8/E9/EC",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Indoor/outdoor communication, receiving error (read with the remote CHECK button)",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-e8-e9-ec"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "FC",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Nonvolatile memory data",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-fc"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "Fd",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Different voltage",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-fd"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "P8",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "4-way valve / pipe temperature",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-p8"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "PL",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Outdoor refrigerant system",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-pl"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "U3",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Discharge temperature thermistor",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-u3"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "U4",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Outdoor thermistor: defrost, fin, P.C. board, ambient or outdoor heat exchanger temperature",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-u4"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "UE",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Stop valve (closed valve)",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-ue"
  },
  {
   "appliance": "ac",
   "brand": "Mitsubishi Electric",
   "code": "UP",
   "also_shown_as": "remote CHECK display",
   "model": "Outdoor unit (MSY-GR, MSY-JS remote check)",
   "meaning": "Outdoor power system",
   "what_to_do": "",
   "source": "https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/GRseries-MSY-GR101315182428VF.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/mitsubishi/#code-up"
  },
  {
   "appliance": "ac",
   "brand": "O General",
   "code": "00",
   "also_shown_as": "remote Service check",
   "model": "ASGG18CGAA-B manual",
   "meaning": "No error detected (the indoor unit beeps several times at 00)",
   "what_to_do": "Nothing to do.",
   "source": "https://www.general-hvac.com/datafiles/W9385302037-0101_OM_En_ASGG18CGAA-B.pdf https://www.general-hvac.com/shared/in/pdf-gcin-support-ctlg-rac-2026-01.pdf https://www.general-hvac.com/in/support/faq/split/0084.html https://www.general-hvac.com/in/support/faq/split/0039.html https://www.general-hvac.com/in/support/faq/split/0216.html",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/ac/o-general/#code-00"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "oLd",
   "also_shown_as": "shown as 000 oLd; icon blinking, Elite",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Overload warning: the load is too high",
   "what_to_do": "Reduce the load. Microtek's troubleshooting for overload says to reduce the load and reset the UPS (the JM manual: overload above 110%).",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-old"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "oLd",
   "also_shown_as": "shown as 000 oLd; icon glows steady, screen locked, Elite",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Overload shutdown: the UPS has switched off its output",
   "what_to_do": "Reduce the load and reset the front panel switch (OFF, then ON).",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-old-2"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "bLo",
   "also_shown_as": "shown as 000 bLo; icon blinking, Elite",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Battery low warning",
   "what_to_do": "Recharge the battery when mains returns (Elite manual). The JM manual's low battery row also says to reduce the load.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-blo"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "bLo",
   "also_shown_as": "shown as 000 bLo; icon glows steady, screen locked, Elite",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Battery low shutdown: the battery is discharged",
   "what_to_do": "Recharge the battery after mains returns, then reset the front ON/OFF switch to get output.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-blo-2"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "bHI",
   "also_shown_as": "shown as 000 bHI",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Battery high shutdown: battery voltage too high",
   "what_to_do": "The manuals give no action for this code. Switch the UPS off and call Microtek authorised service.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-bhi"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "SHt Ct",
   "also_shown_as": "",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Output short circuit (the UPS shuts its output)",
   "what_to_do": "Switch the power ON/OFF switch off to stop the beep, check the wiring, reduce the load and switch on again (JM manual). The Elite manual's short circuit row says: check the wiring, reduce the load and turn the reset switch on the front panel ON-OFF-ON. If the short stays, switch off and call Microtek authorised service.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-sht-ct"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "otP",
   "also_shown_as": "shown as 000 otP",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Over temperature protection",
   "what_to_do": "Let the UPS cool down; the JM manual says it resets to normal by itself, within 30 minutes. If it does not, reset the front switch (off, then on). If it still does not work, the JM manual says it is an internal problem: bypass the UPS with the rotary switch and call the service centre.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-otp"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Cbt",
   "also_shown_as": "shown as 220 Cbt",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Input circuit breaker trip",
   "what_to_do": "Check the MCB (circuit breaker) on the back panel and reset it. The Elite manual's CB trip row says: if it trips again, call the authorised service engineer to check for shorting or overload in the output circuit.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-cbt"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Lo",
   "also_shown_as": "on the input side; the output side shows 220 V, 50 Hz or oFF",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Mains is on but its voltage or frequency is too low (out of the normal range). In backup mode the UPS runs on battery; in mains mode with the power switch off, the output shows oFF",
   "what_to_do": "The manuals give no action for this display. If your mains is actually normal, Microtek's troubleshooting says to check for a dead wall socket or loose AC input connections.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-lo"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "HI",
   "also_shown_as": "on the input side; the output side shows 220 V, 50 Hz or oFF",
   "model": "Elite 1500 LCD, JM SW 2500+ (LCD models)",
   "meaning": "Mains is on but its voltage or frequency is too high (out of the normal range). In backup mode the UPS runs on battery; in mains mode with the power switch off, the output shows oFF",
   "what_to_do": "The manuals give no action for this display. If your mains is actually normal, Microtek's troubleshooting says to check for a dead wall socket or loose AC input connections.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-hi"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "CHr",
   "also_shown_as": "CHr on or FUL, mains mode",
   "model": "Elite 1500 LCD",
   "meaning": "Charger status, shown in mains mode after the input voltage and frequency: CHr on, or CHr on / FUL (the manual says the 0.1 icon means the display shows CHr Ful). A clock icon shows the remaining charging time",
   "what_to_do": "Nothing to do.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-chr"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "oFF",
   "also_shown_as": "on the output side",
   "model": "Elite 1500 LCD",
   "meaning": "Output is off: standby (only the battery connected, ON/OFF switch off), or mains mode with the power switch off",
   "what_to_do": "Nothing to fix.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-off"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Mains LED flashing",
   "also_shown_as": "mains is normal",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "The MCB (circuit breaker) at the back has tripped",
   "what_to_do": "Check the MCB on the back panel. If it is off, switch it on. If it trips again, call Microtek authorised service to check the output wiring for a short or overload.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-mains-led-flashing"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Inverter or UPS LED glowing",
   "also_shown_as": "mains is normal",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "The UPS is running on battery even though mains power is there: dead wall socket, or loose or wrong mains input connection",
   "what_to_do": "Check the wall socket and the mains input lead connection.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-inverter-or-ups-led-glowing"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Overload LED glowing (red)",
   "also_shown_as": "UPS mode, no output",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Overload: too much load on the UPS",
   "what_to_do": "Reduce the load and reset the UPS.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-overload-led-glowing-red"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Overload LED glowing (red)",
   "also_shown_as": "short circuit",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Short circuit in the output",
   "what_to_do": "Remove the load and reset the UPS. If it then works normally, the wiring may be wrong or a load faulty. If the short circuit stays, call authorised service.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-overload-led-glowing-red-2"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Battery Low and Overload LEDs glowing",
   "also_shown_as": "OTP",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Over-temperature protection",
   "what_to_do": "Reduce the load and reset the UPS. Check that the fan is working; if the fan is not working normally, call authorised service.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-battery-low-and-overload-leds-glowing"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Overload LED glowing (red)",
   "also_shown_as": "other faults, alarm buzzing",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Another fault (the Overload LED also flashes or glows for over charging and DC high)",
   "what_to_do": "Reset the UPS. If the alarm keeps buzzing, call authorised service.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-overload-led-glowing-red-3"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Battery Low LED glowing (red)",
   "also_shown_as": "UPS mode, no output",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Battery has discharged",
   "what_to_do": "Recharge the battery when mains returns. Check the battery type selection pins on the back and set them to your battery type.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-battery-low-led-glowing-red"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Charging LED flashing",
   "also_shown_as": "",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Battery is charging (normal)",
   "what_to_do": "Nothing to do.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-charging-led-flashing"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Charging LED glowing steady",
   "also_shown_as": "",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Battery is fully charged (normal)",
   "what_to_do": "Nothing to do.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-charging-led-glowing-steady"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "One 0.5 second beep",
   "also_shown_as": "SW LED on",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Battery low detected",
   "what_to_do": "The buzzer table gives no action. For a low battery, Microtek's troubleshooting table says to recharge the battery after mains comes back and check that the battery type pins on the back are set right.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-one-0-5-second-beep"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "No alarm",
   "also_shown_as": "SW LED off",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Battery low shutdown: the UPS has switched off because the battery is empty",
   "what_to_do": "The buzzer table gives no action. For a low battery, Microtek's troubleshooting table says to recharge the battery after mains comes back and check that the battery type pins on the back are set right.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-no-alarm"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Continuous alarm",
   "also_shown_as": "SW LED on",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "CB trip (circuit breaker tripped)",
   "what_to_do": "The buzzer table gives no action. For an MCB trip, the troubleshooting table says to check the MCB at the back and switch it on if it is off. If it trips again, call authorised service to check the output circuit for a short or overload.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-continuous-alarm"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "One beep",
   "also_shown_as": "SW LED off",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "CB trip (circuit breaker tripped)",
   "what_to_do": "The buzzer table gives no action. For an MCB trip, the troubleshooting table says to check the MCB at the back and switch it on if it is off. If it trips again, call authorised service to check the output circuit for a short or overload.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-one-beep"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "Continuous alarm",
   "also_shown_as": "SW LED off",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "One of these faults: mains mode burning risk protection (TX OTP), battery mode over-temperature (OTP), DC high voltage, output short, output low or output high",
   "what_to_do": "The buzzer table gives no action. Microtek's troubleshooting table says: for over-temperature, reduce the load, reset the UPS and check the fan; for a short circuit, remove the load and reset; for other faults, reset the UPS. If the alarm keeps buzzing, switch the UPS off and call authorised service.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-continuous-alarm-2"
  },
  {
   "appliance": "inverter-ups",
   "brand": "Microtek",
   "code": "One 0.5 second beep",
   "also_shown_as": "SW LED off",
   "model": "Heavy Duty VTurbo NEW (SW and DG)",
   "meaning": "Backfeed fault",
   "what_to_do": "The manual gives no fix for this. It warns that the UPS output must never be connected to a generator or the incoming mains supply. Switch the UPS off and call Microtek authorised service.",
   "source": "https://cms.microtek.in/upload/product/HeavyDuty-Manual-SW---Microtek-1759465643435.pdf https://cms.microtek.in/upload/product/MANUAL-493-HDVT-NEW-DG--V5-1756758439497.pdf https://cms.microtek.in/upload/product/User-Manual-Elite-LCD---Microtek-1758312383918.pdf https://cms.microtek.in/upload/product/MANUAL-002-354-JM-2500-V2-CCF-1723341119961.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/inverter-ups/microtek/#code-one-0-5-second-beep-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "dE",
   "also_shown_as": "drain error",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "Drain error: water is not draining",
   "what_to_do": "Put the drain hose end down on the floor (not hooked on the machine), keep it flat, unblocked and not kinked. No part of it should be more than 20 cm above the floor, and an extension hose should not be longer than 3 m.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-de"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "LId OPn",
   "also_shown_as": "LId / OPn, lid open",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "Lid open error",
   "what_to_do": "Close the lid firmly. The manual also says to check the lid is closed if the machine is not spinning.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-lid-opn"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "Check Water LED flashing",
   "also_shown_as": "with beep, crossed-out tap icon",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "Fill error: no or very low water supply. It shows after about 10 minutes",
   "what_to_do": "Check whether the tap is closed, or the water inlet pipe filter or inlet valve filter is blocked with foreign objects. Open the tap or clean the filter (manual p.17), then press START / PAUSE again. Always make sure there is enough water supply (required water pressure: manual p.6).",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-check-water-led-flashing"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "Voltage fluctuation LED flashing",
   "also_shown_as": "with beep, crossed-out lightning icon",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "Power error: the supply voltage is too low or too high",
   "what_to_do": "Wait. The machine resumes by itself when normal voltage comes back.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-voltage-fluctuation-led-flashing"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "PF",
   "also_shown_as": "power failure",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "There was a power failure while Delay Wash was set. Information only",
   "what_to_do": "Nothing to do; Whirlpool says it does not affect the wash.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-pf"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "Child lock LED glowing",
   "also_shown_as": "",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "Child lock is on: no button works (not a fault). It can be switched on only after pressing START",
   "what_to_do": "Press Express Wash and Delay Wash together until the lock LED goes off. In an urgent case during child lock, Whirlpool says to switch off the main power.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-child-lock-led-glowing"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "E1",
   "also_shown_as": "",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "Whirlpool does not explain E1 in this manual",
   "what_to_do": "Check the instruction sticker on the machine (the manual's control panel page says error details are there), then call Whirlpool Service Centre.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-e1"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "Program group LEDs blinking",
   "also_shown_as": "with beeps",
   "model": "Top load: Stainwash Deep Clean 7.2 (India)",
   "meaning": "Whirlpool does not explain this; the manual only says to call service when the program group LEDs blink with beeps",
   "what_to_do": "Call Whirlpool Service Centre.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-program-group-leds-blinking"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "h2o",
   "also_shown_as": "beeps every 5 s",
   "model": "Front load: Fresh Care 7112",
   "meaning": "The machine is not filling with water",
   "what_to_do": "Check that the inlet hose is connected to the tap and not bent, the tap is open, the mains water supply is on, and there is enough water pressure.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-h2o"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "F-01 or other F- code",
   "also_shown_as": "machine locked, display flashing",
   "model": "Front load: Fresh Care 7112",
   "meaning": "The machine is locked and the display flashes an error code. Whirlpool does not list what each F code means",
   "what_to_do": "Switch off, pull out the plug, wait about 1 minute and switch on again. If it comes back, call Whirlpool after-sales service.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-f-01-or-other-f-code"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "Water filter clogged indicator",
   "also_shown_as": "",
   "model": "Front load: Fresh Care 7112",
   "meaning": "Water cannot be drained; the water filter might be blocked",
   "what_to_do": "The quick guide gives no steps for this icon itself. Its \"does not drain or spin\" checks: the programme may have no drain step (on some programmes you start it by hand), the drain hose may be bent, or the drain line may be blocked.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-water-filter-clogged-indicator"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "No water indicator",
   "also_shown_as": "",
   "model": "Front load: Fresh Care 7112",
   "meaning": "No inlet water, or not enough",
   "what_to_do": "Same checks as h2o: inlet hose connected to the tap and not bent, tap open, mains water supply on, enough water pressure.",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-no-water-indicator"
  },
  {
   "appliance": "washing-machine",
   "brand": "Whirlpool",
   "code": "Call Service indicator",
   "also_shown_as": "",
   "model": "Front load: Fresh Care 7112",
   "meaning": "A failure that needs service",
   "what_to_do": "The quick guide says to refer to its troubleshooting section (the Fresh Care rows on this page).",
   "source": "https://www.manualpdf.in/whirlpool/stainwash-deep-clean-72/manual https://www.manualpdf.in/whirlpool/fresh-care-7112/manual",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/washing-machine/whirlpool/#code-call-service-indicator"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1080",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Backup/Restore timeout: the control panel or PC tool failed to communicate with the drive while a backup was being made or restored.",
   "what_to_do": "Request the backup or restore again.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1080"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1081",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Rating ID fault: the drive software could not read the drive's rating ID.",
   "what_to_do": "Reset the fault so the drive rereads the rating ID. If it comes back, cycle the power (maybe more than once). If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1081"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2281",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Calibration: measured offset of output phase current measurement, or the difference between U2 and W2 current measurement, is too great.",
   "what_to_do": "Try the current calibration again (parameter 99.13). If the fault persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2281"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2310",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Overcurrent: output current has exceeded the internal fault limit. Besides a real overcurrent, an earth fault or supply phase loss can also cause it.",
   "what_to_do": "Check motor load, acceleration times, motor and motor cable (phasing, star/delta), contactors in the motor cable, motor data in group 99, no power factor capacitors or surge absorbers in the motor cable, and insulation.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2310"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2330",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Earth leakage: the drive has detected load unbalance, typically due to an earth fault in the motor or motor cable.",
   "what_to_do": "Check for power factor capacitors or surge absorbers in the motor cable and measure motor and cable insulation. Try scalar control if allowed (99.04). If no earth fault is found, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2330"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2381",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "IGBT overload: excessive IGBT junction to case temperature. Can be caused by a short circuit in the motor cable.",
   "what_to_do": "Check motor cable, ambient conditions, air flow and fan, heatsink fins for dust, and motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2381"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "3130",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Input phase loss: DC voltage is oscillating because an input power line phase is missing or a fuse is blown.",
   "what_to_do": "Check input fuses, loose power cable connections and supply imbalance. If phases are fine and it still trips, ABB says enabling 97.48 Udc stabilizer is reasonable.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-3130"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "3181",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Wiring or earth fault: input power cable is connected to the drive's motor terminals.",
   "what_to_do": "Check input power connections.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-3181"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "3210",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "DC link overvoltage: intermediate circuit DC voltage is too high.",
   "what_to_do": "Check overvoltage control is on (30.30), supply voltage matches the drive, supply for overvoltage, brake chopper and resistor, and deceleration time.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-3210"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "3220",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "DC link undervoltage: DC voltage is not enough because of a missing supply phase, blown fuse or a fault in the rectifier bridge.",
   "what_to_do": "Check supply cabling, fuses and switchgear.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-3220"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "3381",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Output phase loss: motor circuit fault, all three motor phases are not connected.",
   "what_to_do": "Connect the motor cable.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-3381"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "3385",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Autophasing: the autophasing routine has failed.",
   "what_to_do": "Try other autophasing modes (21.13), check the motor ID run was completed, the motor is not already turning, and 99.03 is set to permanent magnet motor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-3385"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4110",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Control board temperature: control unit temperature is too high.",
   "what_to_do": "Check cooling of the drive and the auxiliary cooling fan.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4110"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4210",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "IGBT overtemperature: estimated drive IGBT temperature is excessive.",
   "what_to_do": "Check ambient conditions, air flow and fan, heatsink fins for dust, and motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4210"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4290",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Cooling: drive module temperature is excessive.",
   "what_to_do": "Check ambient temperature and derating, cooling air flow and fan, and clean dust from the cabinet and heatsink.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4290"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "42F1",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "IGBT temperature: drive IGBT temperature is excessive.",
   "what_to_do": "Check ambient conditions, air flow and fan, heatsink fins for dust, and motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-42f1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4310",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Excess temperature: power unit module temperature is excessive.",
   "what_to_do": "See warning A4B0.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4310"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4380",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Excess temperature difference: high temperature difference between the IGBTs of different phases.",
   "what_to_do": "Check the motor cabling and cooling of the drive module(s).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4380"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4981",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "External temperature 1: measured temperature 1 has exceeded the fault limit.",
   "what_to_do": "Check 35.02 and the cooling of the motor or measured equipment.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4981"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4982",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "External temperature 2: measured temperature 2 has exceeded the fault limit.",
   "what_to_do": "Check 35.03 and the cooling of the motor or measured equipment.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4982"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4990",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "CPTC-02 not found: the CPTC-02 extension module is not detected in option slot 2.",
   "what_to_do": "Power down the drive and check the module is properly inserted in slot 2.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4990"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4991",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Safe motor temperature: the CPTC-02 module shows overtemperature (motor too hot, or thermistor shorted or disconnected).",
   "what_to_do": "Check motor cooling, motor load and drive ratings, sensor wiring and sensor resistance.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4991"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5080",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Fan: cooling fan feedback missing (frame R6 or larger).",
   "what_to_do": "See warning A581.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5080"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5081",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Auxiliary fan broken: an auxiliary cooling fan on the control unit fan connectors is stuck or disconnected.",
   "what_to_do": "Check the auxiliary code, fans and connections; replace a faulty fan; make sure the front cover is in place. Reboot the control unit (96.08) or cycle power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5081"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5089",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "SMT circuit malfunction: a safe motor temperature fault is generated but no STO event, fault or warning.",
   "what_to_do": "Check the connection between the module's relay output and the STO terminal.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5089"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5090",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "STO hardware failure: STO hardware diagnostics detected a hardware failure.",
   "what_to_do": "Contact ABB quoting the auxiliary code.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5090"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5091",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Safe torque off: STO safety circuit signal is broken during start or run.",
   "what_to_do": "Check safety circuit connections and parameter 95.04.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5091"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5092",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "PU logic error: power unit memory has cleared.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5092"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5093",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Rating ID mismatch: drive hardware does not match the information in memory (for example after a firmware update).",
   "what_to_do": "Cycle the power (maybe more than once). If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5093"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5094",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Measurement circuit temperature: problem with the drive's internal temperature measurement.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5094"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5098",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "I/O communication loss: communication failure to standard I/O.",
   "what_to_do": "Try resetting the fault or cycle the power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5098"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "50A0",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Fan: cooling fan stuck or disconnected.",
   "what_to_do": "Check fan operation and connection; replace the fan if faulty.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-50a0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5681",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "PU communication: communication errors between the drive control unit and the power unit.",
   "what_to_do": "Check the connection between control unit and power unit, and parameter 95.04.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5681"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5682",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Power unit lost: connection between the control unit and the power unit is lost.",
   "what_to_do": "Check the connection between control unit and power unit.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5682"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5691",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Measurement circuit ADC: measurement circuit fault.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5691"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5692",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "PU board powerfail: power unit power supply failure.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5692"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5693",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Measurement circuit DFF: measurement circuit fault.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5693"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5697",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Charging feedback: charging feedback signal missing.",
   "what_to_do": "Check the feedback signal from the charging system.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5697"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5698",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Unknown PU fault: the power unit logic generated a fault the software does not know.",
   "what_to_do": "Check logic and software compatibility.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5698"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6181",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "FPGA version incompatible: firmware and FPGA versions are incompatible.",
   "what_to_do": "Reboot the control unit (96.08) or cycle power. If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6181"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6200",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Checksum mismatch: actual parameter checksum does not match the approved checksum.",
   "what_to_do": "Revert parameter changes made after approval, or approve the new checksum (96.55 bits 12/13).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6200"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6306",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "FBA A mapping file: fieldbus adapter A mapping file read error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6306"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6481",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Task overload: internal fault.",
   "what_to_do": "Reboot the control unit (96.08) or cycle power. If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6481"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6487",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Stack overflow: internal fault.",
   "what_to_do": "Reboot the control unit (96.08) or cycle power. If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6487"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64A1",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Internal file load: file read error.",
   "what_to_do": "Reboot the control unit (96.08) or cycle power. If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64a1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64A4",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Rating ID fault: rating ID load error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64a4"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64A6",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Adaptive program: error running the adaptive program.",
   "what_to_do": "Check the auxiliary code.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64a6"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64B1",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Internal SSW fault: internal fault.",
   "what_to_do": "Reboot the control unit (96.08) or cycle power. If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64b1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64B2",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "User set fault: loading a user parameter set failed (set missing, not compatible, or drive switched off during loading).",
   "what_to_do": "Make sure a valid user parameter set exists; reload if uncertain.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64b2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64B3",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Macro parameterization error: macro parameterization failed, for example a write to a default value that cannot be changed.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64b3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64E1",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Kernel overload: operating system error.",
   "what_to_do": "Reboot the control unit (96.08) or cycle power. If it persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64e1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6581",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Parameter system: parameter load or save failed.",
   "what_to_do": "Force a save with 96.07 and retry.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6581"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6591",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Backup/Restore timeout: control panel or PC tool stopped communicating during backup or restore.",
   "what_to_do": "Check control panel or PC tool communication.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6591"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "65A1",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "FBA A parameter conflict: the drive does not have a function the PLC requests, or it is not activated.",
   "what_to_do": "Check PLC programming and parameter groups 50 and 51.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-65a1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6681",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "EFB comm loss: communication break in embedded fieldbus (EFB).",
   "what_to_do": "Check the fieldbus master status and cable connections to EIA-485/X5 terminals 29, 30 and 31.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6681"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6682",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "EFB config file: embedded fieldbus configuration file could not be read.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6682"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6683",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "EFB invalid parameterization: embedded fieldbus settings are inconsistent or not compatible with the protocol.",
   "what_to_do": "Check parameter group 58.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6683"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6684",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "EFB load fault: EFB protocol firmware could not be loaded, or its version does not match the drive firmware.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6684"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6685",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "EFB fault 2: fault reserved for the EFB protocol application.",
   "what_to_do": "Check the protocol documentation.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6685"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6686",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "EFB fault 3: fault reserved for the EFB protocol application.",
   "what_to_do": "Check the protocol documentation.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6686"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6882",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Text 32-bit table overflow: internal fault.",
   "what_to_do": "Reset the fault. Contact ABB if it persists.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6882"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6885",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Text file overflow: internal fault.",
   "what_to_do": "Reset the fault. Contact ABB if it persists.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6885"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7081",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Control panel loss: control panel or PC tool selected as control location has stopped communicating.",
   "what_to_do": "Check panel or PC tool connection and connector; disconnect and reconnect the panel.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7081"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7082",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "I/O module comm loss: communication between I/O module and drive is not working properly.",
   "what_to_do": "Check the I/O module installation.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7082"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7085",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Incompatible option module: fieldbus option module not supported.",
   "what_to_do": "Replace the module with a supported type.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7085"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7086",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "AI Overvoltage: overvoltage detected on an analog input; the input is temporarily switched to voltage mode.",
   "what_to_do": "Check AI signal levels.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7086"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7121",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Motor stall: motor is operating in the stall region, for example because of excessive load or too small motor power.",
   "what_to_do": "Check motor load, drive ratings and fault function parameters.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7121"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7122",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Motor overload: continuous average motor current is above motor nominal current.",
   "what_to_do": "Check the motor rotation is not obstructed and the motor torque suits the application; adjust 35.51–35.53 and 35.55–35.56.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7122"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7181",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Brake resistor: brake resistor broken or not connected.",
   "what_to_do": "Check that a brake resistor is connected, its condition and its dimensioning.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7181"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7183",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "BR excess temperature: brake resistor temperature has exceeded the fault limit (43.11).",
   "what_to_do": "Stop the drive and let the resistor cool; check group 43 settings and the braking cycle.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7183"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7191",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "BC short circuit: short circuit in the brake chopper IGBT.",
   "what_to_do": "Make sure the brake resistor is connected and not damaged; check its specifications; replace the brake chopper if replaceable.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7191"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7192",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "BC IGBT excess temperature: brake chopper IGBT temperature has exceeded the internal fault limit.",
   "what_to_do": "Let the chopper cool; check ambient, fan, air flow, group 43 settings, braking cycle and supply voltage.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7192"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7310",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Overspeed: motor is turning faster than the highest allowed speed (wrong min/max speed, too little braking torque, or load changes with torque reference).",
   "what_to_do": "Check 30.11 and 30.12, motor braking torque, torque control, and need for a brake chopper and resistor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7310"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "73B0",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Emergency ramp failed: emergency stop did not finish within the expected time.",
   "what_to_do": "Check 31.32, 31.33 and the ramp times (23.11–23.15 for Off1, 23.23 for Off3).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-73b0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "73F0",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Overfrequency: maximum allowed output frequency exceeded.",
   "what_to_do": "Check the auxiliary code, 30.13 and 30.14, and supply voltage selection 95.01.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-73f0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7510",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "FBA A communication: cyclical communication with fieldbus adapter module A (or between PLC and module A) is lost.",
   "what_to_do": "Check fieldbus status, parameter groups 50–53, cables and that the master can communicate.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7510"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "8001",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "ULC underload fault: signal has been under the user underload curve for too long.",
   "what_to_do": "See parameter 37.04.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-8001"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "8002",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "ULC overload fault: signal has been over the user overload curve for too long.",
   "what_to_do": "See parameter 37.03.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-8002"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "80A0",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "AI supervision: an analog signal is outside the limits set for the analog input.",
   "what_to_do": "Check the signal level, auxiliary code, wiring and the limits in group 12.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-80a0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "80B0",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Signal supervision 1: fault generated by signal supervision function 1.",
   "what_to_do": "Check the source of the fault (parameter 32.07).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-80b0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "80B1",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Signal supervision 2: fault generated by signal supervision function 2.",
   "what_to_do": "Check the source of the fault (parameter 32.17).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-80b1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "80B2",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Signal supervision 3: fault generated by signal supervision function 3.",
   "what_to_do": "Check the source of the fault (parameter 32.27).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-80b2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "80B3",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Signal supervision 4: fault generated by signal supervision function 4.",
   "what_to_do": "Check the source of the fault (parameter 32.37).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-80b3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "80B4",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Signal supervision 5: fault generated by signal supervision function 5.",
   "what_to_do": "Check the source of the fault (parameter 32.47).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-80b4"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "80B5",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Signal supervision 6: fault generated by signal supervision function 6.",
   "what_to_do": "Check the source of the fault (parameter 32.57).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-80b5"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "9081",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "External fault 1: fault in external device 1.",
   "what_to_do": "Check the external device and parameter 31.01.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-9081"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "9082",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "External fault 2: fault in external device 2.",
   "what_to_do": "Check the external device and parameter 31.03.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-9082"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "9083",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "External fault 3: fault in external device 3.",
   "what_to_do": "Check the external device and parameter 31.05.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-9083"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "9084",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "External fault 4: fault in external device 4.",
   "what_to_do": "Check the external device and parameter 31.07.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-9084"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "9085",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "External fault 5: fault in external device 5.",
   "what_to_do": "Check the external device and parameter 31.09.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-9085"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D401",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Max cleaning fault: maximum number of pump cleanings reached in the set time; the pump needs manual cleaning.",
   "what_to_do": "Check the pump for blockages and clean it manually if needed; check 83.35–83.37.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d401"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D404",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Running dry: dry run protection is activated.",
   "what_to_do": "Check the pump inlet has enough water; check 82.20 and 82.21.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d404"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D405",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Pipe fill-timeout: soft pipe fill reached its timeout limit without the PID output reaching the setpoint.",
   "what_to_do": "Check the pipe for leakage; see 82.25 and 82.26.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d405"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D40C",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Cavitation detected: the pump is not getting enough liquid.",
   "what_to_do": "Check the fluid level, restart the pump and see if cavitation continues; adjust 86.12–86.30 if needed.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d40c"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "FA81",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Safe torque off 1: STO circuit 1 is broken.",
   "what_to_do": "Check safety circuit connections and parameter 95.04.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-fa81"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "FA82",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "Safe torque off 2: STO circuit 2 is broken.",
   "what_to_do": "Check safety circuit connections and parameter 95.04.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-fa82"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "FF61",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "ID run: motor ID run was not completed.",
   "what_to_do": "Check motor data in group 99, no external control system connected, motor shaft not locked, and the auxiliary code; cycle the power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-ff61"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "FF63",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "STO diagnostics failure: software internal malfunction.",
   "what_to_do": "Reboot the control unit (96.08) or cycle power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-ff63"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "FF81",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "FB A force trip: a fault trip command was received through fieldbus adapter A.",
   "what_to_do": "Check the fault information from the PLC.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-ff81"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "FF8E",
   "also_shown_as": "",
   "model": "ACS580",
   "meaning": "EFB force trip: a fault trip command was received through the embedded fieldbus.",
   "what_to_do": "Check the fault information from the PLC.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-ff8e"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "64FF",
   "also_shown_as": "",
   "model": "ACS580 event",
   "meaning": "Fault reset: a fault has been reset from the control panel, Drive composer, fieldbus or I/O. Informative only.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-64ff"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "B686",
   "also_shown_as": "",
   "model": "ACS580 event",
   "meaning": "Checksum mismatch: parameter checksum does not match the approved checksum. Event, informative only.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-b686"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "B5A0",
   "also_shown_as": "",
   "model": "ACS580 event",
   "meaning": "STO event: Safe torque off is active (STO signal lost). Informative.",
   "what_to_do": "Check safety circuit connections.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-b5a0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A2A1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Current calibration: current offset and gain calibration will occur at next start. Informative.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a2a1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A2B1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Overcurrent: output current has exceeded the internal fault limit; can also be caused by an earth fault or supply phase loss.",
   "what_to_do": "Same checks as fault 2310: motor load, acceleration times, motor and cable, insulation, group 99.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a2b1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A2B3",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Earth leakage: load unbalance, typically an earth fault in the motor or motor cable.",
   "what_to_do": "Check for power factor capacitors or surge absorbers in the motor cable and measure insulation. If no earth fault is found, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a2b3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A2B4",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Short circuit: short circuit in motor cable(s) or motor.",
   "what_to_do": "Check motor and cable for cabling errors, phasing, insulation and power factor capacitors; on frames R6–R11 check the auxiliary code.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a2b4"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A2BA",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "IGBT overload: excessive IGBT junction to case temperature; can be caused by a short circuit in the motor cable.",
   "what_to_do": "Check motor cable, ambient, air flow, fan, heatsink dust, motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a2ba"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A3A1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "DC link overvoltage: DC voltage too high while the drive is stopped.",
   "what_to_do": "Check the supply voltage setting (95.01) and the supply voltage. ABB notes a wrong 95.01 setting may make the motor rush uncontrollably or overload the brake chopper or resistor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a3a1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A3A2",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "DC link undervoltage: DC voltage too low while the drive is stopped.",
   "what_to_do": "Check the supply voltage setting (95.01) and the supply voltage. ABB notes a wrong 95.01 setting may make the motor rush uncontrollably or overload the brake chopper or resistor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a3a2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A3AA",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "DC not charged: DC circuit voltage has not yet risen to operating level.",
   "what_to_do": "If the problem persists, contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a3aa"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A490",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Incorrect temperature sensor setup: temperature cannot be supervised because of wrong adapter or AO setup.",
   "what_to_do": "Check 35.11 and 35.21 against AO parameters 13.12 and 13.22.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a490"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A491",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "External temperature 1: measured temperature 1 has exceeded the warning limit.",
   "what_to_do": "Check 35.02, the cooling of the measured equipment and 35.13.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a491"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A492",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "External temperature 2: measured temperature 2 has exceeded the warning limit.",
   "what_to_do": "Check 35.03, the cooling of the measured equipment and 35.23.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a492"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A4A0",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Control board temperature: control unit temperature is too high (aux code 1 = thermistor broken).",
   "what_to_do": "Check ambient, air flow, fan and heatsink dust. Aux code 1: contact ABB for control unit replacement.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a4a0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A4A1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "IGBT overtemperature: estimated drive IGBT temperature is excessive.",
   "what_to_do": "Check ambient, air flow and fan, heatsink dust, motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a4a1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A4A9",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Cooling: drive module temperature is excessive.",
   "what_to_do": "Check ambient temperature and derating, cooling air flow and fan, and dust in the cabinet and heatsink.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a4a9"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A4B0",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Excess temperature: power unit module temperature is excessive.",
   "what_to_do": "Check ambient, air flow and fan, heatsink dust, motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a4b0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A4B1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Excess temperature difference: high temperature difference between IGBTs of different phases.",
   "what_to_do": "Check the motor cabling and drive module cooling.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a4b1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A4F6",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "IGBT temperature: drive IGBT temperature is excessive.",
   "what_to_do": "Check ambient, air flow and fan, heatsink dust, motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a4f6"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A581",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Fan: cooling fan feedback missing (frame R6 or larger).",
   "what_to_do": "Check the auxiliary code, fan operation and connection; replace the fan if faulty.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a581"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A582",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Auxiliary fan missing: an auxiliary cooling fan (IP55 internal fan) is stuck or disconnected.",
   "what_to_do": "Check the fan and connection; replace a faulty fan; make sure the front cover is in place and tightened.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a582"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A5A0",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Safe torque off: STO is active, the safety circuit signal to the STO connector is lost.",
   "what_to_do": "Check safety circuit connections and parameter 95.04.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a5a0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A5EA",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Measurement circuit temperature: problem with the drive's internal temperature measurement.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a5ea"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A5EB",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "PU board powerfail: power unit power supply failure.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a5eb"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A5ED",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Measurement circuit ADC: measurement circuit fault.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a5ed"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A5EE",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Measurement circuit DFF: measurement circuit fault.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a5ee"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A5EF",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "PU state feedback: state feedback from output phases does not match control signals.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a5ef"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A5F0",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Charging feedback: charging feedback signal missing.",
   "what_to_do": "Check the feedback signal from the charging system.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a5f0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A682",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Flash erase speed exceeded: the flash memory has been erased too often, shortening its life.",
   "what_to_do": "Avoid unnecessary forced parameter saves (96.07) and cyclic parameter writes.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a682"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A686",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Checksum mismatch: actual parameter checksum does not match the approved checksum.",
   "what_to_do": "Revert parameter changes, or approve the new checksum (96.55 bits 12/13).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a686"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6A4",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Motor nominal value: motor parameters are set wrong, or the drive is not sized correctly.",
   "what_to_do": "Check the auxiliary code, groups 98 and 99, and that the drive suits the motor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6a4"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6A5",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "No motor data: parameters in group 99 have not been set. Normal during start-up until motor data is entered.",
   "what_to_do": "Set all required parameters in group 99.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6a5"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6A6",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Voltage category unselected: the voltage category has not been defined.",
   "what_to_do": "Set it in parameter 95.01 Supply voltage.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6a6"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6A7",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "System time not set: timed functions cannot be used and fault log dates are wrong.",
   "what_to_do": "Set the time manually or connect the control panel; or disable timed functions (34.10).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6a7"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6B0",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "User lock is open: user lock configuration parameters 96.100–96.102 are visible.",
   "what_to_do": "Close the user lock by entering an invalid pass code in 96.02.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6b0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6B1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "User pass code not confirmed: a new pass code was entered in 96.100 but not confirmed in 96.101.",
   "what_to_do": "Enter the same code in 96.101, or close the user lock to cancel.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6b1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6D1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "FBA A parameter conflict: the drive lacks a function the PLC requests, or it is not activated.",
   "what_to_do": "Check PLC programming and parameter group 50.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6d1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6E5",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "AI parametrization: an analog input's current/voltage hardware setting does not match the parameter settings.",
   "what_to_do": "Adjust the hardware setting or 12.15/12.25, then reboot the control unit.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6e5"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A6E6",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ULC configuration: user load curve configuration error.",
   "what_to_do": "Check the auxiliary code and the points in group 37.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a6e6"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A780",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Motor stall: motor is operating in the stall region (for example excessive load or too small motor power).",
   "what_to_do": "Check motor load, drive ratings and fault function parameters.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a780"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A783",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Motor overload: motor current is too high.",
   "what_to_do": "Check for an overloaded motor; adjust 35.51–35.53 and 35.55–35.56.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a783"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A784",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Motor disconnect: all three output phases are disconnected from the motor.",
   "what_to_do": "Check switches between drive and motor are closed and all motor cables are connected.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a784"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A793",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "BR excess temperature: brake resistor temperature has exceeded the warning limit (43.12).",
   "what_to_do": "Stop the drive and let the resistor cool; check group 43, resistor sizing and braking cycle.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a793"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A794",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "BR data: brake resistor data has not been given.",
   "what_to_do": "Check 43.08–43.10 (the auxiliary code names the parameter).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a794"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A79C",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "BC IGBT excess temperature: brake chopper IGBT temperature has exceeded the internal warning limit.",
   "what_to_do": "Let the chopper cool; check ambient, fan, air flow, cabinet cooling, 43.06–43.10, braking cycle and supply voltage.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a79c"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A7A2",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Mechanical brake opening failed: brake acknowledgement is not as expected when opening.",
   "what_to_do": "Check brake connection, group 44 and the acknowledgement signal.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a7a2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A7AB",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Extension I/O configuration failure: installed C-type module is not as configured, or communication is disturbed.",
   "what_to_do": "Check 15.02 matches 15.01; remove disturbance sources.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a7ab"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A7C1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "FBA A communication: cyclical communication with fieldbus adapter A is lost.",
   "what_to_do": "Check fieldbus status, groups 50–53, cables and the master.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a7c1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A7CE",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "EFB comm loss: communication break in embedded fieldbus.",
   "what_to_do": "Check the master status and cables to EIA-485/X5 terminals 29, 30 and 31.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a7ce"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A7EE",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Panel loss: control panel or PC tool selected as control location has stopped communicating.",
   "what_to_do": "Check the panel or PC tool connection, connector and mounting platform; reconnect the panel.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a7ee"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A88F",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Cooling fan: maintenance timer limit exceeded.",
   "what_to_do": "Consider changing the cooling fan (05.04 shows fan running time).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a88f"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8A0",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "AI supervision: an analog signal is outside the limits set for the analog input.",
   "what_to_do": "Check signal level, wiring and limits in group 12.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8a0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8A1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "RO life warning: a relay output has changed state more than the recommended number of times.",
   "what_to_do": "Change the control unit or stop using that relay output.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8a1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8A2",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "RO toggle warning: a relay output is switching faster than recommended; relay life will be exceeded soon.",
   "what_to_do": "Connect a less frequently changing signal (10.24, 10.27 or 10.30).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8a2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8B0",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ABB Signal supervision 1: warning generated by signal supervision function 1.",
   "what_to_do": "Check the source of the warning (parameter 32.07).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8b0"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8B1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ABB Signal supervision 2: warning generated by signal supervision function 2.",
   "what_to_do": "Check the source of the warning (parameter 32.17).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8b1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8B2",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ABB Signal supervision 3: warning generated by signal supervision function 3.",
   "what_to_do": "Check the source of the warning (parameter 32.27).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8b2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8B3",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ABB Signal supervision 4: warning generated by signal supervision function 4.",
   "what_to_do": "Check the source of the warning (parameter 32.37).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8b3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8B4",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ABB Signal supervision 5: warning generated by signal supervision function 5.",
   "what_to_do": "Check the source of the warning (parameter 32.47).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8b4"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8B5",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ABB Signal supervision 6: warning generated by signal supervision function 6.",
   "what_to_do": "Check the source of the warning (parameter 32.57).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8b5"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8BE",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ULC overload warning: selected signal has exceeded the user overload curve.",
   "what_to_do": "Check for conditions raising the signal (for example motor load) and the curve in group 37.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8be"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A8BF",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "ULC underload warning: selected signal has fallen below the user underload curve.",
   "what_to_do": "Check for conditions lowering the signal (for example loss of load) and the curve in group 37.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a8bf"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A981",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "External warning 1: fault in external device 1.",
   "what_to_do": "Check the external device and parameter 31.01.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a981"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A982",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "External warning 2: fault in external device 2.",
   "what_to_do": "Check the external device and parameter 31.03.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a982"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A983",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "External warning 3: fault in external device 3.",
   "what_to_do": "Check the external device and parameter 31.05.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a983"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A984",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "External warning 4: fault in external device 4.",
   "what_to_do": "Check the external device and parameter 31.07.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a984"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "A985",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "External warning 5: fault in external device 5.",
   "what_to_do": "Check the external device and parameter 31.09.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-a985"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AF88",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Season configuration warning: a season is set to start before the previous season.",
   "what_to_do": "Set increasing start dates in 34.60–34.63.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-af88"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AF90",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Speed controller autotuning: the speed controller autotune did not complete.",
   "what_to_do": "Check the auxiliary code.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-af90"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFAA",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Autoreset: a fault is about to be autoreset. Informative.",
   "what_to_do": "See parameter group 31.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-afaa"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFE1",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Emergency stop (off2): the drive has received an emergency stop (off2) command.",
   "what_to_do": "Check it is safe to continue, return the emergency stop button to normal, restart the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-afe1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFE2",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Emergency stop (off1 or off3): the drive has received an emergency stop (off1 or off3) command.",
   "what_to_do": "If unintentional, check the source in 21.05.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-afe2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFE9",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Start delay: start delay is active; the drive will start the motor after a set delay. Informative.",
   "what_to_do": "See parameter 21.22.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-afe9"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFEB",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Run enable missing: no run enable signal is received.",
   "what_to_do": "Check 20.12 and switch the signal on, or check wiring of the source.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-afeb"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFED",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Enable to rotate: the enable to rotate signal was not received within 240 s.",
   "what_to_do": "Switch the signal on and check 20.22.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-afed"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFF6",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Identification run: motor ID run will occur at next start. Informative.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-aff6"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "AFF8",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Motor heating active: motor pre-heating current (21.16) is passing through the motor. Informative.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-aff8"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D501",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "No more available PFC motors: no more PFC motors can start (interlocked or in Hand mode).",
   "what_to_do": "Check interlocks 76.81–76.84; if all motors are in use, the PFC system is too small for the demand.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d501"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D502",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "All motors interlocked: all motors in the PFC system are interlocked.",
   "what_to_do": "Check interlocks 76.81–76.84.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d502"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D503",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "VSD controlled PFC motor interlocked: the motor on the drive is interlocked and cannot start.",
   "what_to_do": "Remove the interlock (76.81–76.84).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d503"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D505",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Max cleaning warning: maximum number of pump cleanings reached in the set time; manual cleaning needed.",
   "what_to_do": "Check the pump for blockages, clean it manually if needed; check 83.35–83.37.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d505"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D506",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Pump cleaning not possible: drive must be in remote control with the start signal on.",
   "what_to_do": "Change control location to Auto.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d506"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D507",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Pump cleaning needed: dirt detection says the pump needs cleaning but automatic cleaning is not allowed.",
   "what_to_do": "Clean the pump manually, or start cleaning with 83.12.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d507"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D50A",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Running dry: dry run protection is activated.",
   "what_to_do": "Check the pump inlet has enough water; check 82.20 and 82.21.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d50a"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D50B",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Pipe fill-timeout: soft pipe fill reached its timeout limit.",
   "what_to_do": "Check the pipe for leakage; see 82.25 and 82.26.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d50b"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D511",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Cavitation control: cavitation control warning.",
   "what_to_do": "Check the auxiliary code, the fluid level and group 86 settings.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d511"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D58B",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Gas pressure outside limits: compressor gas pressure is outside the limits.",
   "what_to_do": "Check the limits set as AI min and max values.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d58b"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D590",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Restart delay: compressor restart delay; the drive cannot start until it has passed.",
   "what_to_do": "Wait, and check parameter 21.40.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d590"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D591",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Min. run time: compressor minimum run time; the drive runs at minimum speed during it.",
   "what_to_do": "Check parameter 21.41.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d591"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "D602",
   "also_shown_as": "",
   "model": "ACS580 warning",
   "meaning": "Cavitation tune completed: cavitation auto tune has finished and stopped the drive. Information only.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-d602"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0001",
   "also_shown_as": "fieldbus code 2310",
   "model": "ACS355",
   "meaning": "OVERCURRENT: output current has exceeded the trip level (sudden load change or stall, short acceleration time, wrong motor data, motor or drive too small, damaged motor or cables, wrong star/delta, internal fault, or noise in STO lines).",
   "what_to_do": "Check motor load, acceleration time (2202, 2205), motor data (group 99), sizing, motor, cables and connections.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0001"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0002",
   "also_shown_as": "fieldbus code 3210",
   "model": "ACS355",
   "meaning": "DC OVERVOLT: DC voltage too high (trip at 420 V on 200 V drives, 840 V on 400 V drives): high or noisy supply, floating network, or during deceleration: overvoltage controller off, short deceleration time, faulty or undersized brake chopper.",
   "what_to_do": "Check input voltage, overvoltage controller (2005), deceleration time (2203, 2206), brake chopper and resistor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0002"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0003",
   "also_shown_as": "fieldbus code 4210",
   "model": "ACS355",
   "meaning": "DEV OVERTEMP: drive IGBT temperature is excessive (high ambient, blocked air flow, fan not working, or drive overload).",
   "what_to_do": "Check ambient, free space and air flow, fan operation. ABB allows 50% overload for one minute in ten minutes.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0003"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0004",
   "also_shown_as": "fieldbus code 2340",
   "model": "ACS355",
   "meaning": "SHORT CIRC: short circuit in motor cable(s) or motor; also internal drive fault or noise in STO lines.",
   "what_to_do": "Check motor and cable insulation and the motor winding.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0004"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0006",
   "also_shown_as": "fieldbus code 3220",
   "model": "ACS355",
   "meaning": "DC UNDERVOLT: DC voltage not sufficient (undervoltage controller off, missing input phase, blown fuse, or rectifier bridge fault).",
   "what_to_do": "Check input supply and fuses, undervoltage controller (2006); measure input and DC voltage (0107).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0006"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0007",
   "also_shown_as": "fieldbus code 8110",
   "model": "ACS355",
   "meaning": "AI1 LOSS: analog input AI1 has fallen below 3021 AI1 FAULT LIMIT (signal weak or missing).",
   "what_to_do": "Check the signal source and wiring, and parameters 3001 and 3021.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0007"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0008",
   "also_shown_as": "fieldbus code 8110",
   "model": "ACS355",
   "meaning": "AI2 LOSS: analog input AI2 has fallen below 3022 AI2 FAULT LIMIT (signal weak or missing).",
   "what_to_do": "Check the signal source and wiring, and parameter 3001.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0008"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0009",
   "also_shown_as": "fieldbus code 4310",
   "model": "ACS355",
   "meaning": "MOT OVERTEMP: motor temperature estimate too high (excessive load, too small motor, wrong start-up data), or measured motor temperature above 3504 FAULT LIMIT.",
   "what_to_do": "Check motor ratings, load, cooling and start-up data; let the motor cool down.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0009"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0010",
   "also_shown_as": "fieldbus code 5300",
   "model": "ACS355",
   "meaning": "PANEL LOSS: control panel selected as control location has stopped communicating.",
   "what_to_do": "Check panel connection and connector, parameter 3002; refit the panel.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0010"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0011",
   "also_shown_as": "fieldbus code FF84",
   "model": "ACS355",
   "meaning": "ID RUN FAIL: motor ID run did not complete.",
   "what_to_do": "Check motor connection, group 99, and that 2002 is at least 80% of motor nominal speed (9908).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0011"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0012",
   "also_shown_as": "fieldbus code 7121",
   "model": "ACS355",
   "meaning": "MOTOR STALL: motor is operating in the stall region (excessive load or too small motor).",
   "what_to_do": "Check motor load, drive ratings and 3010–3012.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0012"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0014",
   "also_shown_as": "fieldbus code 9000",
   "model": "ACS355",
   "meaning": "EXT FAULT 1: external fault 1.",
   "what_to_do": "Check external devices and parameter 3003.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0014"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0015",
   "also_shown_as": "fieldbus code 9001",
   "model": "ACS355",
   "meaning": "EXT FAULT 2: external fault 2.",
   "what_to_do": "Check external devices and parameter 3004.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0015"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0016",
   "also_shown_as": "fieldbus code 2330",
   "model": "ACS355",
   "meaning": "EARTH FAULT: earth (ground) fault in motor or motor cable, or a drive internal fault.",
   "what_to_do": "Check motor and motor cable; cable must not exceed maximum length. ABB notes disabling earth fault may damage the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0016"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0017",
   "also_shown_as": "fieldbus code FF6A",
   "model": "ACS355",
   "meaning": "UNDERLOAD: motor load too low, for example a release mechanism in the driven equipment.",
   "what_to_do": "Check the driven equipment, fault function parameters, motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0017"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0018",
   "also_shown_as": "fieldbus code 5210",
   "model": "ACS355",
   "meaning": "THERM FAIL: drive temperature exceeds the operating level of the thermistor, or the internal thermistor is open or shorted.",
   "what_to_do": "Check the ambient temperature is not too low. Internal fault: replace the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0018"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0021",
   "also_shown_as": "fieldbus code 2211",
   "model": "ACS355",
   "meaning": "CURR MEAS: drive internal fault, current measurement out of range.",
   "what_to_do": "Replace the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0021"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0022",
   "also_shown_as": "fieldbus code 3130",
   "model": "ACS355",
   "meaning": "SUPPLY PHASE: DC voltage oscillating because an input phase is missing or a fuse is blown (ripple above 14% of nominal).",
   "what_to_do": "Check input fuses, installation, supply imbalance, load, and 2619 DC STABILIZER.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0022"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0023",
   "also_shown_as": "fieldbus code 7301",
   "model": "ACS355",
   "meaning": "ENCODER ERR: communication fault between pulse encoder and interface module, or module and drive.",
   "what_to_do": "Check encoder, wiring, interface module and group 50.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0023"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0024",
   "also_shown_as": "fieldbus code 7310",
   "model": "ACS355",
   "meaning": "OVERSPEED: motor turning faster than 120% of the highest allowed speed.",
   "what_to_do": "Check min/max speed (2001, 2002) or frequency (2007, 2008), braking torque, torque control, brake chopper and resistor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0024"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0027",
   "also_shown_as": "fieldbus code 630F",
   "model": "ACS355",
   "meaning": "CONFIG FILE: internal configuration file error.",
   "what_to_do": "Replace the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0027"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0028",
   "also_shown_as": "fieldbus code 7510",
   "model": "ACS355",
   "meaning": "SERIAL 1 ERR: fieldbus communication break.",
   "what_to_do": "Check fieldbus status, 3018 and 3019, connections and noise, and that the master can communicate.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0028"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0029",
   "also_shown_as": "fieldbus code 6306",
   "model": "ACS355",
   "meaning": "EFB CON FILE: error reading the embedded fieldbus configuration file.",
   "what_to_do": "See the fieldbus user's manual.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0029"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0030",
   "also_shown_as": "fieldbus code FF90",
   "model": "ACS355",
   "meaning": "FORCE TRIP: trip command received from fieldbus.",
   "what_to_do": "See the fieldbus user's manual.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0030"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0034",
   "also_shown_as": "fieldbus code FF56",
   "model": "ACS355",
   "meaning": "MOTOR PHASE: motor circuit fault, missing motor phase or motor thermistor relay fault.",
   "what_to_do": "Check motor, motor cable and thermistor relay (if used).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0034"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0035",
   "also_shown_as": "fieldbus code FF95",
   "model": "ACS355",
   "meaning": "OUTP WIRING: input power cable connected to the drive's motor terminals. Can also show on a delta grounded supply with high motor cable capacitance.",
   "what_to_do": "Check input power is not connected to the drive output. Can be disabled with 3023.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0035"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0036",
   "also_shown_as": "fieldbus code 630F",
   "model": "ACS355",
   "meaning": "INCOMPATIBLE SW: loaded software is not compatible with the drive.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0036"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0037",
   "also_shown_as": "fieldbus code 4110",
   "model": "ACS355",
   "meaning": "CB OVERTEMP: control board overheated (95 °C on IP20, 102 °C on IP66), with 3024 set to fault.",
   "what_to_do": "Check ambient, fan, air flow and cabinet cooling.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0037"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0044",
   "also_shown_as": "fieldbus code FFA0",
   "model": "ACS355",
   "meaning": "SAFE TORQUE OFF: STO requested and working; 3025 STO OPERATION set to fault.",
   "what_to_do": "If unexpected, check STO safety circuit cabling (terminals X1C). Reset the fault before starting.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0044"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0045",
   "also_shown_as": "fieldbus code FFA1",
   "model": "ACS355",
   "meaning": "STO1 LOST: STO channel 1 has not de-energized but channel 2 has (damaged contacts or short circuit).",
   "what_to_do": "Check STO circuit cabling and contacts.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0045"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0046",
   "also_shown_as": "fieldbus code FFA2",
   "model": "ACS355",
   "meaning": "STO2 LOST: STO channel 2 has not de-energized but channel 1 has (damaged contacts or short circuit).",
   "what_to_do": "Check STO circuit cabling and contacts.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0046"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0101",
   "also_shown_as": "fieldbus code FF55",
   "model": "ACS355",
   "meaning": "SERF CORRUPT: drive internal error.",
   "what_to_do": "Replace the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0101"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0103",
   "also_shown_as": "fieldbus code FF55",
   "model": "ACS355",
   "meaning": "SERF MACRO: drive internal error (ABB's table gives one shared cause and action for 0101 and 0103).",
   "what_to_do": "Replace the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0103"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0201",
   "also_shown_as": "fieldbus code 6100",
   "model": "ACS355",
   "meaning": "DSP T1 OVERLOAD: drive internal error.",
   "what_to_do": "If fieldbus is used, check it; note the code and contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0201"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0202",
   "also_shown_as": "fieldbus code 6100",
   "model": "ACS355",
   "meaning": "DSP T2 OVERLOAD: drive internal error (ABB's table gives one shared cause and action for 0201–0204).",
   "what_to_do": "If fieldbus is used, check it; note the code and contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0202"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0203",
   "also_shown_as": "fieldbus code 6100",
   "model": "ACS355",
   "meaning": "DSP T3 OVERLOAD: drive internal error (ABB's table gives one shared cause and action for 0201–0204).",
   "what_to_do": "If fieldbus is used, check it; note the code and contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0203"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0204",
   "also_shown_as": "fieldbus code 6100",
   "model": "ACS355",
   "meaning": "DSP STACK ERROR: drive internal error (ABB's table gives one shared cause and action for 0201–0204).",
   "what_to_do": "If fieldbus is used, check it; note the code and contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0204"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "0206",
   "also_shown_as": "fieldbus code 5000",
   "model": "ACS355",
   "meaning": "CB ID ERROR: drive internal error.",
   "what_to_do": "Replace the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-0206"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1000",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR HZRPM: wrong speed or frequency limit setting.",
   "what_to_do": "Check 2001 < 2002, 2007 < 2008, and the ratios to 9907/9908 are in range.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1000"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1003",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR AI SCALE: wrong analog input scaling.",
   "what_to_do": "Check 1301 < 1302 and 1304 < 1305.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1003"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1004",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR AO SCALE: wrong analog output scaling.",
   "what_to_do": "Check 1504 < 1505.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1004"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1005",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR PCU 2: wrong motor nominal power setting.",
   "what_to_do": "Check 9909 MOTOR NOM POWER against motor current and voltage.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1005"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1006",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR EXT RO: wrong relay output extension parameters.",
   "what_to_do": "Check MREL-01 module is connected (0181) and relay outputs 1402, 1403, 1410.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1006"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1007",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR FBUSMISS: fieldbus control has not been activated.",
   "what_to_do": "Check fieldbus parameter settings.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1007"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1009",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR PCU 1: wrong motor nominal speed or frequency setting.",
   "what_to_do": "Check 9907, 9908 and 9913.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1009"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1015",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR USER U/F: wrong voltage to frequency (U/f) ratio setting.",
   "what_to_do": "Check 2610–2617.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1015"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1017",
   "also_shown_as": "fieldbus code 6320",
   "model": "ACS355",
   "meaning": "PAR SETUP 1: only two of MTAC-01 encoder module, frequency input and frequency output can be used at the same time.",
   "what_to_do": "Disable the frequency output, frequency input or encoder.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1017"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2001",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "OVERCURRENT: output current limit controller is active; high ambient temperature.",
   "what_to_do": "Check ambient; load capacity drops above 40 °C. See fault 0001.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2001"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2002",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "OVERVOLTAGE: DC overvoltage controller is active.",
   "what_to_do": "See fault 0002.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2002"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2003",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "UNDERVOLTAGE: DC undervoltage controller is active.",
   "what_to_do": "See fault 0006.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2003"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2004",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "DIR LOCK: change of direction is not allowed.",
   "what_to_do": "Check parameter 1003 DIRECTION.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2004"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2005",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "IO COMM: fieldbus communication break.",
   "what_to_do": "Check fieldbus status, fault function parameters, connections and the master.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2005"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2006",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "AI1 LOSS: analog input AI1 below the 3021 limit.",
   "what_to_do": "See fault 0007.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2006"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2007",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "AI2 LOSS: analog input AI2 below the 3022 limit.",
   "what_to_do": "See fault 0008.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2007"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2008",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "PANEL LOSS: control panel selected as control location has stopped communicating.",
   "what_to_do": "See fault 0010.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2008"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2009",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "DEVICE OVERTEMP: drive IGBT temperature is excessive.",
   "what_to_do": "Check ambient, air flow and fan, motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2009"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2010",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "MOTOR TEMP: motor temperature too high (or appears so), or measured temperature above 3503 ALARM LIMIT.",
   "what_to_do": "See fault 0009.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2010"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2011",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "UNDERLOAD: motor load is too low.",
   "what_to_do": "Check the driven equipment, fault function parameters, motor power against drive power.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2011"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2012",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "MOTOR STALL: motor operating in the stall region.",
   "what_to_do": "Check motor load, drive ratings and fault function parameters.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2012"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2013",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "AUTORESET: automatic reset alarm.",
   "what_to_do": "Check parameter group 31.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2013"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2018",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "PID SLEEP: sleep function has entered sleeping mode.",
   "what_to_do": "See parameter groups 40 and 41.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2018"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2019",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "ID RUN: motor identification run is on. Normal during start-up.",
   "what_to_do": "Wait until the drive shows identification is completed.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2019"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2021",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "START ENABLE 1 MISSING: no Start enable 1 signal received.",
   "what_to_do": "Check 1608, digital inputs and fieldbus settings.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2021"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2022",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "START ENABLE 2 MISSING: no Start enable 2 signal received.",
   "what_to_do": "Check 1609, digital inputs and fieldbus settings.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2022"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2023",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "EMERGENCY STOP: drive received an emergency stop command and ramps to stop (2208).",
   "what_to_do": "Check it is safe to continue, then return the emergency stop button to normal.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2023"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2024",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "ENCODER ERROR: communication fault between pulse encoder and interface module, or module and drive.",
   "what_to_do": "Check encoder, wiring, module and group 50.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2024"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2025",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "FIRST START: motor identification magnetization is on. Normal during start-up.",
   "what_to_do": "Wait until the drive shows identification is completed.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2025"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2026",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "INPUT PHASE LOSS: DC voltage oscillating because an input phase is missing or a fuse is blown.",
   "what_to_do": "Check input fuses, supply imbalance and fault function parameters.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2026"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2029",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "MOTOR BACK EMF: a permanent magnet motor is rotating with start mode DC MAGN selected; it cannot be magnetized with DC.",
   "what_to_do": "To start a rotating motor, set 2101 START FUNCTION to 1 (AUTO); otherwise the drive starts after the motor stops.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2029"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2035",
   "also_shown_as": "",
   "model": "ACS355 alarm",
   "meaning": "SAFE TORQUE OFF: STO requested and working; 3025 set to alarm.",
   "what_to_do": "If unexpected, check STO cabling (X1C). Toggle the start signal if STO was used while running.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2035"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5001",
   "also_shown_as": "A5001 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Drive is not responding.",
   "what_to_do": "Check panel connection.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5001"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5002",
   "also_shown_as": "A5002 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Incompatible communication profile.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5002"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5010",
   "also_shown_as": "A5010 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Corrupted panel parameter backup file.",
   "what_to_do": "Retry parameter upload or download.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5010"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5011",
   "also_shown_as": "A5011 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Drive is controlled from another source.",
   "what_to_do": "Change drive control to local control mode.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5011"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5012",
   "also_shown_as": "A5012 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Direction of rotation is locked.",
   "what_to_do": "Enable change of direction (1003).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5012"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5013",
   "also_shown_as": "A5013 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Panel control disabled because start inhibit is active.",
   "what_to_do": "Reset the emergency stop or remove the 3-wire stop command before starting from the panel.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5013"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5014",
   "also_shown_as": "A5014 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Panel control disabled because of a drive fault.",
   "what_to_do": "Reset the drive fault and retry.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5014"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5015",
   "also_shown_as": "A5015 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Panel control disabled because local control mode lock is active.",
   "what_to_do": "Deactivate the lock (1606) and retry.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5015"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5018",
   "also_shown_as": "A5018 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter default value not found.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5018"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5019",
   "also_shown_as": "A5019 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Writing a non-zero parameter value is prohibited.",
   "what_to_do": "Only parameter reset is allowed.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5019"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5020",
   "also_shown_as": "A5020 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter or group does not exist, or value is inconsistent.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5020"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5021",
   "also_shown_as": "A5021 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter or group is hidden.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5021"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5022",
   "also_shown_as": "A5022 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter is write protected.",
   "what_to_do": "The value is read-only.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5022"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5023",
   "also_shown_as": "A5023 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter change not allowed while the drive is running.",
   "what_to_do": "Stop the drive, then change the value.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5023"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5024",
   "also_shown_as": "A5024 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Drive is executing a task.",
   "what_to_do": "Wait until the task is completed.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5024"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5025",
   "also_shown_as": "A5025 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Software is being uploaded or downloaded.",
   "what_to_do": "Wait until upload/download is complete.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5025"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5026",
   "also_shown_as": "A5026 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Value is at or below minimum limit.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5026"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5027",
   "also_shown_as": "A5027 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Value is at or above maximum limit.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5027"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5028",
   "also_shown_as": "A5028 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Invalid value.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5028"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5029",
   "also_shown_as": "A5029 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Memory is not ready.",
   "what_to_do": "Retry.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5029"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5030",
   "also_shown_as": "A5030 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Invalid request.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5030"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5031",
   "also_shown_as": "A5031 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Drive not ready for operation, for example low DC voltage.",
   "what_to_do": "Check input power supply.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5031"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5032",
   "also_shown_as": "A5032 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5032"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5040",
   "also_shown_as": "A5040 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download error: selected parameter set is not in the backup file.",
   "what_to_do": "Upload before download.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5040"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5041",
   "also_shown_as": "A5041 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter backup file does not fit into memory.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5041"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5042",
   "also_shown_as": "A5042 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download error: selected parameter set is not in the backup file.",
   "what_to_do": "Upload before download.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5042"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5043",
   "also_shown_as": "A5043 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "No start inhibit.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5043"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5044",
   "also_shown_as": "A5044 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter backup file restoring error.",
   "what_to_do": "Check the file is compatible with the drive.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5044"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5050",
   "also_shown_as": "A5050 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter upload aborted.",
   "what_to_do": "Retry upload.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5050"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5051",
   "also_shown_as": "A5051 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "File error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5051"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5052",
   "also_shown_as": "A5052 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter upload has failed.",
   "what_to_do": "Retry upload.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5052"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5060",
   "also_shown_as": "A5060 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download aborted.",
   "what_to_do": "Retry download.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5060"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5062",
   "also_shown_as": "A5062 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download has failed.",
   "what_to_do": "Retry download.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5062"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5070",
   "also_shown_as": "A5070 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Panel backup memory write error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5070"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5071",
   "also_shown_as": "A5071 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Panel backup memory read error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5071"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5080",
   "also_shown_as": "A5080 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Not allowed: drive is not in local control mode.",
   "what_to_do": "Switch to local control mode.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5080-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5081",
   "also_shown_as": "A5081 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Not allowed because of an active fault.",
   "what_to_do": "Check the cause and reset the fault.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5081-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5083",
   "also_shown_as": "A5083 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Not allowed: parameter lock is on.",
   "what_to_do": "Check 1602 PARAMETER LOCK.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5083"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5084",
   "also_shown_as": "A5084 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Not allowed: drive is performing a task.",
   "what_to_do": "Wait and retry.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5084"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5085",
   "also_shown_as": "A5085 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download between drives failed.",
   "what_to_do": "Check both drives are the same type (ACS355).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5085"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5086",
   "also_shown_as": "A5086 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download between drives failed.",
   "what_to_do": "Check both drives have the same type designation.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5086"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5087",
   "also_shown_as": "A5087 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download failed: parameter sets incompatible.",
   "what_to_do": "Check drive information in group 33 is the same.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5087"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5088",
   "also_shown_as": "A5088 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Operation failed: drive memory error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5088"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5089",
   "also_shown_as": "A5089 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Download failed: CRC error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5089-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5090",
   "also_shown_as": "A5090 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Download failed: data processing error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5090-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5091",
   "also_shown_as": "A5091 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Operation failed: parameter error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5091-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5092",
   "also_shown_as": "A5092 on basic panel",
   "model": "ACS355 panel alarm",
   "meaning": "Parameter download failed: parameter sets incompatible.",
   "what_to_do": "Check drive information in group 33 is the same.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5092-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1",
   "also_shown_as": "F0001 on basic panel",
   "model": "ACS550",
   "meaning": "OVERCURRENT: output current is excessive.",
   "what_to_do": "Check motor load, acceleration time (2202, 2205), motor, motor cables and connections.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2",
   "also_shown_as": "F0002 on basic panel",
   "model": "ACS550",
   "meaning": "DC OVERVOLT: intermediate circuit DC voltage is excessive.",
   "what_to_do": "Check supply for overvoltage, deceleration time (2203, 2206), brake chopper size, and overvoltage controller ON (2005).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "3",
   "also_shown_as": "F0003 on basic panel",
   "model": "ACS550",
   "meaning": "DEV OVERTEMP: drive heatsink overheated (115 °C on R1–R4, 125 °C on R5–R6).",
   "what_to_do": "Check fan, air flow, dust on heatsink, ambient temperature, motor load.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "4",
   "also_shown_as": "F0004 on basic panel",
   "model": "ACS550",
   "meaning": "SHORT CIRC: fault current.",
   "what_to_do": "Check for a short circuit in motor cable(s) or motor, and supply disturbances.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-4"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "6",
   "also_shown_as": "F0006 on basic panel",
   "model": "ACS550",
   "meaning": "DC UNDERVOLT: intermediate circuit DC voltage is not sufficient.",
   "what_to_do": "Check for a missing input phase, blown fuse, low mains voltage.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-6"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "7",
   "also_shown_as": "F0007 on basic panel",
   "model": "ACS550",
   "meaning": "AI1 LOSS: analog input 1 is below AI1 FAULT LIMIT (3021).",
   "what_to_do": "Check the input source and connection, 3021 and 3001.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-7"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "8",
   "also_shown_as": "F0008 on basic panel",
   "model": "ACS550",
   "meaning": "AI2 LOSS: analog input 2 is below AI2 FAULT LIMIT (3022).",
   "what_to_do": "Check the input source and connection, 3022 and 3001.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-8"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "9",
   "also_shown_as": "F0009 on basic panel",
   "model": "ACS550",
   "meaning": "MOT OVERTEMP: motor is too hot (drive estimate or temperature feedback).",
   "what_to_do": "Check for an overloaded motor, 3005–3009, temperature sensors and group 35.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-9"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "10",
   "also_shown_as": "F0010 on basic panel",
   "model": "ACS550",
   "meaning": "PANEL LOSS: panel communication lost while in local control, or in remote control set to take commands from the panel.",
   "what_to_do": "Check communication lines, 3002, and groups 10 and 11.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-10"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "11",
   "also_shown_as": "F0011 on basic panel",
   "model": "ACS550",
   "meaning": "ID RUN FAIL: motor ID run was not completed.",
   "what_to_do": "Check motor connections and 9905–9909.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-11"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "12",
   "also_shown_as": "F0012 on basic panel",
   "model": "ACS550",
   "meaning": "MOTOR STALL: motor or process stall, motor in the stall region.",
   "what_to_do": "Check for excessive load, too small motor, and 3010–3012.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-12"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "14",
   "also_shown_as": "F0014 on basic panel",
   "model": "ACS550",
   "meaning": "EXT FAULT 1: digital input set for external fault 1 is active.",
   "what_to_do": "See parameter 3003.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-14"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "15",
   "also_shown_as": "F0015 on basic panel",
   "model": "ACS550",
   "meaning": "EXT FAULT 2: digital input set for external fault 2 is active.",
   "what_to_do": "See parameter 3004.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-15"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "16",
   "also_shown_as": "F0016 on basic panel",
   "model": "ACS550",
   "meaning": "EARTH FAULT: possible ground fault in the motor or motor cables. More sensitive when stopped; can give false trips.",
   "what_to_do": "Check input wiring and motor cable length; detection level 3028. ABB notes disabling it (3023, 3017) may void the warranty.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-16"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "18",
   "also_shown_as": "F0018 on basic panel",
   "model": "ACS550",
   "meaning": "THERM FAIL: internal fault, drive temperature thermistor open or shorted.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-18"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "19",
   "also_shown_as": "F0019 on basic panel",
   "model": "ACS550",
   "meaning": "OPEX LINK: internal fault on the fiber optic link between control and OINT boards.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-19"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "20",
   "also_shown_as": "F0020 on basic panel",
   "model": "ACS550",
   "meaning": "OPEX PWR: internal fault, very low voltage on the OINT power supply.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-20"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "21",
   "also_shown_as": "F0021 on basic panel",
   "model": "ACS550",
   "meaning": "CURR MEAS: internal fault, current measurement out of range.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-21"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "22",
   "also_shown_as": "F0022 on basic panel",
   "model": "ACS550",
   "meaning": "SUPPLY PHASE: ripple voltage in the DC link is too high.",
   "what_to_do": "Check for a missing mains phase or blown fuse.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-22"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "23",
   "also_shown_as": "F0023 on basic panel",
   "model": "ACS550",
   "meaning": "ENCODER ERR: no valid encoder signal.",
   "what_to_do": "Check encoder connection, logic levels, OTAC-01 module, 5001 PULSE NR and 5002.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-23"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "24",
   "also_shown_as": "F0024 on basic panel",
   "model": "ACS550",
   "meaning": "OVERSPEED: motor speed above 120% of the larger of 2001 and 2002.",
   "what_to_do": "Check 2001 and 2002, braking torque, torque control, brake chopper and resistor.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-24"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "26",
   "also_shown_as": "F0026 on basic panel",
   "model": "ACS550",
   "meaning": "DRIVE ID: internal fault, configuration block drive ID not valid.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-26"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "27",
   "also_shown_as": "F0027 on basic panel",
   "model": "ACS550",
   "meaning": "CONFIG FILE: internal configuration file has an error.",
   "what_to_do": "Contact ABB.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-27"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "28",
   "also_shown_as": "F0028 on basic panel",
   "model": "ACS550",
   "meaning": "SERIAL 1 ERR: fieldbus communication has timed out.",
   "what_to_do": "Check 3018 and 3019, group 51 or 53, connections and noise.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-28"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "29",
   "also_shown_as": "F0029 on basic panel",
   "model": "ACS550",
   "meaning": "EFB CON FILE: error reading the embedded fieldbus configuration file.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-29"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "30",
   "also_shown_as": "F0030 on basic panel",
   "model": "ACS550",
   "meaning": "FORCE TRIP: fault trip forced by the fieldbus.",
   "what_to_do": "See the fieldbus user's manual.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-30"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "31",
   "also_shown_as": "F0031 on basic panel",
   "model": "ACS550",
   "meaning": "EFB 1: reserved for the embedded fieldbus protocol; meaning depends on the protocol.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-31"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "32",
   "also_shown_as": "F0032 on basic panel",
   "model": "ACS550",
   "meaning": "EFB 2: reserved for the embedded fieldbus protocol; meaning depends on the protocol (description shared with 31 EFB 1).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-32"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "33",
   "also_shown_as": "F0033 on basic panel",
   "model": "ACS550",
   "meaning": "EFB 3: reserved for the embedded fieldbus protocol; meaning depends on the protocol (description shared with 31 EFB 1).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-33"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "34",
   "also_shown_as": "F0034 on basic panel",
   "model": "ACS550",
   "meaning": "MOTOR PHASE: one motor phase is lost.",
   "what_to_do": "Check motor, motor cable, thermal relay (if used); can be an internal fault.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-34"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "35",
   "also_shown_as": "F0035 on basic panel",
   "model": "ACS550",
   "meaning": "OUTP WIRING: input power cable connected to the drive's motor terminals. Can be falsely declared on a delta grounded supply with large cable capacitance.",
   "what_to_do": "Check input power connections and grounding. Can be disabled with 3023.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-35"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "36",
   "also_shown_as": "F0036 on basic panel",
   "model": "ACS550",
   "meaning": "INCOMPATIBLE SW: the drive cannot use the loaded software.",
   "what_to_do": "Call ABB support.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-36"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "37",
   "also_shown_as": "F0037 on basic panel",
   "model": "ACS550",
   "meaning": "CB OVERTEMP: control board overheated (trip at 88 °C). Not for OMIO control boards.",
   "what_to_do": "Check ambient temperature, fan, air flow.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-37"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "38",
   "also_shown_as": "F0038 on basic panel",
   "model": "ACS550",
   "meaning": "USER LOAD CURVE: condition in 3701 has been valid longer than 3703.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-38"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "101…199",
   "also_shown_as": "",
   "model": "ACS550",
   "meaning": "SYSTEM ERROR: error internal to the drive.",
   "what_to_do": "Contact ABB and report the error number.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-101-199"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "201…299",
   "also_shown_as": "",
   "model": "ACS550",
   "meaning": "SYSTEM ERROR: error in the system.",
   "what_to_do": "Contact ABB and report the error number.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-201-299"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "UNKNOWN DRIVE TYPE",
   "also_shown_as": "",
   "model": "ACS550",
   "meaning": "Wrong type of control panel connected (supports another drive, not the ACS550).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-unknown-drive-type"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1000",
   "also_shown_as": "F1000 on basic panel",
   "model": "ACS550",
   "meaning": "PAR HZRPM: speed or frequency limit parameters are inconsistent.",
   "what_to_do": "Check 2001 < 2002, 2007 < 2008, and ratios to 9907/9908.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1000-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1001",
   "also_shown_as": "F1001 on basic panel",
   "model": "ACS550",
   "meaning": "PAR PFC REF NEG: 2007 MINIMUM FREQ is negative while PFC (8123) is active.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1001"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1003",
   "also_shown_as": "F1003 on basic panel",
   "model": "ACS550",
   "meaning": "PAR AI SCALE: analog input scaling inconsistent.",
   "what_to_do": "Check 1301 < 1302 and 1304 < 1305.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1003-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1004",
   "also_shown_as": "F1004 on basic panel",
   "model": "ACS550",
   "meaning": "PAR AO SCALE: analog output scaling inconsistent.",
   "what_to_do": "Check 1504 < 1505 and 1510 < 1511.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1004-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1005",
   "also_shown_as": "F1005 on basic panel",
   "model": "ACS550",
   "meaning": "PAR PCU 2: motor nominal kVA or power inconsistent.",
   "what_to_do": "Check 9905, 9906 and 9909.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1005-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1006",
   "also_shown_as": "F1006 on basic panel",
   "model": "ACS550",
   "meaning": "PAR EXT RO: extension relay module not connected but 1410–1412 are non-zero.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1006-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1007",
   "also_shown_as": "F1007 on basic panel",
   "model": "ACS550",
   "meaning": "PAR FIELDBUS MISSING: a parameter is set for fieldbus control but 9802 COMM PROT SEL = 0.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1007-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1008",
   "also_shown_as": "F1008 on basic panel",
   "model": "ACS550",
   "meaning": "PAR PFC MODE: 9904 must be 3 (SCALAR:FREQ) when PFC (8123) is active.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1008"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1009",
   "also_shown_as": "F1009 on basic panel",
   "model": "ACS550",
   "meaning": "PAR PCU 1: motor nominal frequency or speed inconsistent.",
   "what_to_do": "Check 9907 and 9908.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1009-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1012",
   "also_shown_as": "F1012 on basic panel",
   "model": "ACS550",
   "meaning": "PAR PFC IO 1: not enough relays set for PFC, or conflict between group 14, 8117 and 8118.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1012"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1013",
   "also_shown_as": "F1013 on basic panel",
   "model": "ACS550",
   "meaning": "PAR PFC IO 2: number of PFC motors (8127) does not match group 14 and 8118.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1013"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1014",
   "also_shown_as": "F1014 on basic panel",
   "model": "ACS550",
   "meaning": "PAR PFC IO 3: the drive cannot allocate an interlock digital input for each PFC motor (8120, 8127).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1014"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "1016",
   "also_shown_as": "F1016 on basic panel",
   "model": "ACS550",
   "meaning": "PAR USER LOAD C: user load curve parameters inconsistent.",
   "what_to_do": "Check load frequencies 3704 < 3707 < 3710 < 3713 < 3716 and each low torque below its high torque.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-1016"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2001",
   "also_shown_as": "A2001",
   "model": "ACS550 alarm",
   "meaning": "OVERCURRENT: current limiting controller is active.",
   "what_to_do": "Check motor load, acceleration time (2202, 2205), motor, cables and connections.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2001-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2002",
   "also_shown_as": "A2002",
   "model": "ACS550 alarm",
   "meaning": "OVERVOLTAGE: overvoltage controller is active.",
   "what_to_do": "Check supply for overvoltage and deceleration time (2203, 2206).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2002-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2003",
   "also_shown_as": "A2003",
   "model": "ACS550 alarm",
   "meaning": "UNDERVOLTAGE: undervoltage controller is active.",
   "what_to_do": "Check for undervoltage on mains.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2003-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2004",
   "also_shown_as": "A2004",
   "model": "ACS550 alarm",
   "meaning": "DIR LOCK: the direction change is not allowed.",
   "what_to_do": "Do not change direction, or allow it in 1003 (if reverse is safe).",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2004-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2005",
   "also_shown_as": "A2005",
   "model": "ACS550 alarm",
   "meaning": "IO COMM: fieldbus communication has timed out.",
   "what_to_do": "Check 3018 and 3019, group 51 or 53, connections and noise.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2005-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2006",
   "also_shown_as": "A2006",
   "model": "ACS550 alarm",
   "meaning": "AI1 LOSS: analog input 1 lost or below the minimum.",
   "what_to_do": "Check input source and connections, 3021 and 3001.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2006-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2007",
   "also_shown_as": "A2007",
   "model": "ACS550 alarm",
   "meaning": "AI2 LOSS: analog input 2 lost or below the minimum.",
   "what_to_do": "Check input source and connections, 3022 and 3001.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2007-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2008",
   "also_shown_as": "A2008",
   "model": "ACS550 alarm",
   "meaning": "PANEL LOSS: panel communication lost (local control, or remote set to take panel commands).",
   "what_to_do": "Check communication lines, 3002, and groups 10 and 11.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2008-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2009",
   "also_shown_as": "A2009",
   "model": "ACS550 alarm",
   "meaning": "DEVICE OVERTEMP: drive heatsink is hot (100 °C R1–R4, 110 °C R5–R6); a DEV OVERTEMP fault may be near.",
   "what_to_do": "Check fan, air flow, heatsink dust, ambient, motor load.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2009-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2010",
   "also_shown_as": "A2010",
   "model": "ACS550 alarm",
   "meaning": "MOTOR TEMP: motor is hot; a MOT OVERTEMP fault may be near.",
   "what_to_do": "Check for overload, 3005–3009, sensors and group 35.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2010-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2012",
   "also_shown_as": "A2012",
   "model": "ACS550 alarm",
   "meaning": "MOTOR STALL: motor in the stall region; a MOTOR STALL fault may be near.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2012-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2013",
   "also_shown_as": "A2013",
   "model": "ACS550 alarm",
   "meaning": "AUTORESET: the drive is about to auto-reset a fault, which may start the motor.",
   "what_to_do": "Use group 31 to control automatic reset.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2013-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2014",
   "also_shown_as": "A2014",
   "model": "ACS550 alarm",
   "meaning": "AUTOCHANGE: PFC autochange function is active.",
   "what_to_do": "Use group 81 to control PFC.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2014"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2015",
   "also_shown_as": "A2015",
   "model": "ACS550 alarm",
   "meaning": "PFC I LOCK: PFC interlocks are active; the drive cannot start the motor(s).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2015"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2018",
   "also_shown_as": "A2018",
   "model": "ACS550 alarm",
   "meaning": "PID SLEEP: PID sleep is active; the motor could accelerate when it ends.",
   "what_to_do": "Use 4022–4026 or 4122–4126.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2018-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2019",
   "also_shown_as": "A2019",
   "model": "ACS550 alarm",
   "meaning": "ID RUN: performing ID run.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2019-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2021",
   "also_shown_as": "A2021",
   "model": "ACS550 alarm",
   "meaning": "START ENABLE 1 MISSING: the Start Enable 1 signal is missing.",
   "what_to_do": "Check 1608, digital input configuration and communication settings.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2021-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2022",
   "also_shown_as": "A2022",
   "model": "ACS550 alarm",
   "meaning": "START ENABLE 2 MISSING: the Start Enable 2 signal is missing.",
   "what_to_do": "Check 1609, digital input configuration and communication settings.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2022-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2023",
   "also_shown_as": "A2023",
   "model": "ACS550 alarm",
   "meaning": "EMERGENCY STOP: emergency stop activated.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2023-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2024",
   "also_shown_as": "A2024",
   "model": "ACS550 alarm",
   "meaning": "ENCODER ERROR: no valid encoder signal.",
   "what_to_do": "Check encoder connection, logic levels, OTAC-01, 5001 and 5002.",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2024-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2025",
   "also_shown_as": "A2025",
   "model": "ACS550 alarm",
   "meaning": "FIRST START: First Start evaluation of motor characteristics. Normal the first time after motor data is entered or changed.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2025-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2027",
   "also_shown_as": "A2027",
   "model": "ACS550 alarm",
   "meaning": "USER LOAD CURVE: condition in 3701 valid longer than half the time in 3703.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2027"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "2028",
   "also_shown_as": "A2028",
   "model": "ACS550 alarm",
   "meaning": "START DELAY: shown during the start delay (2113).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-2028"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5001",
   "also_shown_as": "A5001 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Drive is not responding.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5001-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5002",
   "also_shown_as": "A5002 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "The communication profile is incompatible with the drive.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5002-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5010",
   "also_shown_as": "A5010 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "The panel's parameter backup file is corrupted.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5010-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5011",
   "also_shown_as": "A5011 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Drive is controlled from another source.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5011-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5012",
   "also_shown_as": "A5012 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Rotation direction is locked.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5012-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5013",
   "also_shown_as": "A5013 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Button disabled because start is inhibited.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5013-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5014",
   "also_shown_as": "A5014 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Button disabled because the drive is faulted.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5014-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5015",
   "also_shown_as": "A5015 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Button disabled because local mode lock is on.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5015-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5018",
   "also_shown_as": "A5018 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter default value can't be found.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5018-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5019",
   "also_shown_as": "A5019 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Writing a non-zero value is prohibited (only zero can be written).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5019-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5020",
   "also_shown_as": "A5020 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Group or parameter does not exist, or parameter value is inconsistent.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5020-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5021",
   "also_shown_as": "A5021 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Group or parameter is hidden.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5021-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5022",
   "also_shown_as": "A5022 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Group or parameter is write protected.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5022-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5023",
   "also_shown_as": "A5023 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Modification not allowed while the drive is running.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5023-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5024",
   "also_shown_as": "A5024 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Drive is busy, try again.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5024-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5025",
   "also_shown_as": "A5025 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Write not allowed while upload or download is in progress.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5025-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5026",
   "also_shown_as": "A5026 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Value is at or below low limit.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5026-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5027",
   "also_shown_as": "A5027 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Value is at or above high limit.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5027-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5028",
   "also_shown_as": "A5028 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Value is invalid (not in the list of allowed values).",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5028-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5029",
   "also_shown_as": "A5029 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Memory is not ready, try again.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5029-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5030",
   "also_shown_as": "A5030 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Request is invalid.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5030-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5031",
   "also_shown_as": "A5031 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Drive is not ready, for example due to low DC voltage.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5031-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5032",
   "also_shown_as": "A5032 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter error was detected.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5032-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5040",
   "also_shown_as": "A5040 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Selected parameter set can't be found in the current parameter backup.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5040-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5041",
   "also_shown_as": "A5041 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter backup doesn't fit into memory.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5041-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5042",
   "also_shown_as": "A5042 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Selected parameter set can't be found in the current parameter backup.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5042-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5043",
   "also_shown_as": "A5043 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "No start inhibit was granted.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5043-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5044",
   "also_shown_as": "A5044 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter backup versions do not match.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5044-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5050",
   "also_shown_as": "A5050 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter upload was aborted.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5050-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5051",
   "also_shown_as": "A5051 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "File error was detected.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5051-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5052",
   "also_shown_as": "A5052 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter upload attempt has failed.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5052-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5060",
   "also_shown_as": "A5060 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter download was aborted.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5060-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5062",
   "also_shown_as": "A5062 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Parameter download attempt has failed.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5062-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5070",
   "also_shown_as": "A5070 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Panel backup memory write error.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5070-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5071",
   "also_shown_as": "A5071 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Panel backup memory read error.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5071-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5080",
   "also_shown_as": "A5080 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Not allowed because the drive is not in local mode.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5080-3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5081",
   "also_shown_as": "A5081 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Not allowed because a fault is active.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5081-3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5083",
   "also_shown_as": "A5083 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Not allowed because parameter lock is not open.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5083-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5084",
   "also_shown_as": "A5084 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Not allowed because the drive is busy, try again.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5084-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5085",
   "also_shown_as": "A5085 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Download not allowed: drive types are incompatible.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5085-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5086",
   "also_shown_as": "A5086 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Download not allowed: drive models are incompatible.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5086-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5087",
   "also_shown_as": "A5087 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Download not allowed: parameter sets do not match.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5087-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5088",
   "also_shown_as": "A5088 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Operation failed: drive memory error.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5088-2"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5089",
   "also_shown_as": "A5089 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Download failed: CRC error.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5089-3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5090",
   "also_shown_as": "A5090 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Download failed: data processing error.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5090-3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5091",
   "also_shown_as": "A5091 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Operation failed: parameter error.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5091-3"
  },
  {
   "appliance": "vfd",
   "brand": "ABB",
   "code": "5092",
   "also_shown_as": "A5092 on basic panel",
   "model": "ACS550 panel alarm",
   "meaning": "Download failed: parameter sets do not match.",
   "what_to_do": "",
   "source": "https://library.e.abb.com/public/805f31a82d524d8aa8a750011e2cd001/EN_ACS355_UM_E_A5.pdf https://library.e.abb.com/public/313b6ebaf237059fc1257d0a0048fd68/EN_ACS550_01_UM_H_A4.pdf https://library.e.abb.com/public/d03c76db17d34239a838ed3baf814028/EN_ACS580_FW_J_A5.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/abb/#code-5092-3"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CrF1",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Precharge: charging relay control fault or charging resistor damaged",
   "what_to_do": "Turn the drive off and back on; check the connections and the stability of the main supply. Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-crf1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InFI",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Unknown drive rating: the power card is different from the card stored",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-infi"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InF2",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Unknown or incompatible power board: the power card is incompatible with the control card",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InF3",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Internal serial link: communication interruption between the internal cards",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf3"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InF4",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Invalid industrialization zone: inconsistent internal data",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf4"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InF9",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Current measurement circuit: current measurement is not correct due to the hardware circuit",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf9"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "----",
   "also_shown_as": "",
   "model": "ATV12, ATV310",
   "meaning": "Problem with the application firmware: invalid application firmware update using the Multi-Loader tool",
   "what_to_do": "Flash (re-download) the application firmware of the product again.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-dashes"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InFb",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Internal thermal sensor fault: the drive temperature sensor is not operating correctly, or is in short circuit or open",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-infb"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InFE",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Internal CPU: internal microprocessor fault",
   "what_to_do": "Turn the drive off and back on. Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-infe"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OCF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Overcurrent: motor control parameters (drC- menu) not correct, inertia or load too high, or mechanical locking",
   "what_to_do": "Check the parameters, the size of the motor/drive/load and the state of the mechanism; connect line chokes; reduce the switching frequency SFr; check the ground connection of the drive, the motor cable and the motor insulation.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ocf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF1",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Motor or ground short circuit: short circuit or grounding at the drive output",
   "what_to_do": "Check the cables connecting the drive to the motor, and the motor insulation; connect motor chokes. (The ATV12 manual prints SCF1 and SCF3 in one shared cell.)",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF3",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Ground short circuit: ground fault while running, motors switched while running, or significant current leakage to ground with several motors in parallel",
   "what_to_do": "Check the cables connecting the drive to the motor, and the motor insulation; connect motor chokes. (The ATV12 manual prints SCF1 and SCF3 in one shared cell.)",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf3"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF4",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "IGBT short circuit: internal power component short circuit detected at power-on",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf4"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SOF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Overspeed: instability, or overspeed linked to the inertia of the application",
   "what_to_do": "Check the motor; overspeed is 10% above Maximum frequency tFr, so adjust tFr if needed; add a braking resistor; check the size of the motor/drive/load and the speed loop parameters (gain and stability).",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-sof"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "tnF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Auto-tuning fault: motor not connected, one motor phase lost, special motor, or motor rotating (for example driven by the load)",
   "what_to_do": "Check that the motor and drive are compatible and that the motor is present and completely stopped during auto-tuning; if an output contactor is used, close it during auto-tuning.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-tnf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "LFF1",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "AI current lost: AI1 is set as a current input, its 0% scaling CrL1 is above 3 mA, and the input current is below 2 mA",
   "what_to_do": "Check the terminal connection.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-lff1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "ObF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Overbraking: braking too sudden or driving load too high",
   "what_to_do": "Increase the deceleration time; install a module unit with a braking resistor if necessary; check that the line supply voltage is under the maximum acceptable.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-obf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OHF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Drive overheat: drive temperature too high",
   "what_to_do": "Check the motor load, the drive ventilation and the ambient temperature. Wait for the drive to cool down before restarting.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ohf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OLC",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Process overload",
   "what_to_do": "Check that the process and the drive parameters are in phase.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-olc"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OLF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Motor overload: triggered by excessive motor current",
   "what_to_do": "Check the setting of the motor thermal protection and the motor load.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-olf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OPF1",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "1 output phase loss: loss of one phase at the drive output",
   "what_to_do": "Check the connections from the drive to the motor; with a downstream contactor, check the connection, cable and contactor.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-opf1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OPF2",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "3 output phase loss: motor not connected, motor power below 6% of the drive nominal current, output contactor open, or instantaneous instability in the motor current",
   "what_to_do": "Check the connections from the drive to the motor. To test without a matching motor, set Output Phase loss detection OPL = nO. Check UFr, UnS and nCr and perform Auto-tuning tUn.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-opf2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OSF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Main overvoltage: line voltage too high (10% over the maximum at power-on, or 20% over the maximum with no run order) or disturbed line supply",
   "what_to_do": "Turn off the drive; check and adjust the line voltage; power on again once it is back to nominal. If OSF comes and goes, relay R1 can be set to FLt and connected to upstream protection.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-osf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "PHF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Input phase loss: drive incorrectly supplied or a fuse blown, one phase failed, 3-phase ATV12 on a 1-phase supply, or unbalanced load (only operates with the drive on load)",
   "what_to_do": "Check the power connection and the fuses; use a 3-phase supply. The fault can be disabled with Input Phase loss detection IPL = nO.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-phf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF5",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Load short circuit: short circuit at the drive output (also detected at the run or DC injection order if IGBT test Strt = YES)",
   "what_to_do": "Check the cables connecting the drive to the motor, and the motor insulation.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf5"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SLF1",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Modbus communication: interruption in communication on the Modbus network",
   "what_to_do": "Check the bus connections and the time-out (Modbus time out ttO); refer to the Modbus user manual.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-slf1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SLF2",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "SoMove communication: communication interruption with SoMove",
   "what_to_do": "Check the SoMove connecting cable and the time-out.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-slf2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SLF3",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "HMI communication: communication interruption with the external display terminal",
   "what_to_do": "Check the terminal connection.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-slf3"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SPIF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "PI feedback fault: PID feedback below the lower limit",
   "what_to_do": "Check the PID function feedback, the PI feedback supervision threshold LPI and time delay tPI.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-spif"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "ULF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Process underload: motor current below the underload threshold LUL for the time set in ULt",
   "what_to_do": "Check that the process and the drive parameters are in phase.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ulf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "tJF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "IGBT overheat: drive overheated; IGBT internal temperature too high for the ambient temperature and load",
   "what_to_do": "Check the size of the load/motor/drive; reduce the switching frequency SFr; wait for the drive to cool before restarting.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-tjf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "EPF1",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "External fault by logic input: event triggered by an external device",
   "what_to_do": "Check the device which caused the trip and reset.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-epf1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CFF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Incorrect configuration: HMI block replaced by one configured on a drive with a different rating, or customer parameters inconsistent",
   "what_to_do": "Return to factory settings or retrieve the backup configuration, if it is valid. If the fault remains after factory settings, contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cff"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CFI",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Invalid configuration: the configuration loaded through the bus or network is inconsistent, or the upload was interrupted or not finished",
   "what_to_do": "Check the configuration loaded previously; load a compatible configuration.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cfi"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CFI2",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Download invalid configuration: download with Loader or SoMove was interrupted",
   "what_to_do": "Check the connection with Loader or SoMove; restart the download or restore the factory setting.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cfi2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "USF",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Undervoltage: line supply too low, or transient voltage dip",
   "what_to_do": "Check the voltage and the parameters of the Undervoltage/Phase Loss menu USb-.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-usf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F001",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Precharge: charging relay control fault or charging resistor damaged",
   "what_to_do": "Turn the drive off and back on; check the connections and the stability of the main supply. Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f001"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F002",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Unknown drive rating: power card and stored card versions different",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f002"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F003",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Unknown or incompatible power board: the power card is incompatible with the control card",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f003"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F004",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Internal serial link fault: communication interruption between the internal cards",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f004"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F005",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Invalid industrialization zone: internal data inconsistent",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f005"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F006",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Current measurement circuit fault: current measurement is not correct due to the hardware circuit",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f006"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F007",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Internal thermal sensor fault: the drive temperature sensor is not operating correctly, or is in short circuit or open",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f007"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F008",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Internal CPU: internal microprocessor fault",
   "what_to_do": "Turn the drive off and back on. Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f008"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F010",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Overcurrent: motor control parameters (menu 300-) not correct, inertia or load too high, or mechanical locking",
   "what_to_do": "Check the parameters, the size of the motor/drive/load and the state of the mechanism; connect line motor chokes; reduce the switching frequency range 315; check the ground connection of the drive, the motor cable and the motor insulation.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f010"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F018",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Motor short-circuit: short circuit or grounding at the drive output",
   "what_to_do": "Verify the cables connecting the drive to the motor and the motor insulation; adjust the switching frequency; connect chokes in series with the motor; verify the adjustment of the speed loop. (The ATV310 manual prints F018 and F019 in one shared cell.)",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f018"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F019",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Ground short-circuit: ground fault while running, motor switching while running, or significant current leakage to ground with several motors in parallel",
   "what_to_do": "Verify the cables connecting the drive to the motor and the motor insulation; adjust the switching frequency; connect chokes in series with the motor; verify the adjustment of the speed loop. (The ATV310 manual prints F018 and F019 in one shared cell.)",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f019"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F020",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "IGBT short circuit: internal power component short circuit detected at power on",
   "what_to_do": "Contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f020"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F025",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Overspeed: instability, or overspeed linked to the inertia of the application",
   "what_to_do": "Check the motor; if overspeed is 10% above Top frequency 308, adjust it if needed; add a braking resistor; check the size of the motor/drive/load and the speed loop parameters (gain and stability).",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f025"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F028",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Autotuning fault: motor not connected, motor phase loss, special motor, or motor rotating (for example driven by the load)",
   "what_to_do": "Check that the motor and drive are compatible and that the motor is present and completely stopped; if a downstream output contactor is used, close it during auto-tuning.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f028"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F036",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Angle setting fault: during the phase-shift angle measurement, a motor phase is disconnected or the motor inductance is too high",
   "what_to_do": "Check the motor phases and the maximum current allowed by the drive.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f036"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F009",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Overbraking: sudden braking or load inertia too high",
   "what_to_do": "Increase the deceleration time; install a module unit with a braking resistor if necessary; check that the main supply voltage is under the maximum acceptable.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f009"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F011",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Drive overheat: drive temperature too high",
   "what_to_do": "Check the motor load, the drive ventilation and the ambient temperature. Wait for the drive to cool down before restarting.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f011"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F012",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Process overload fault",
   "what_to_do": "Check that the drive parameters and the application process are compatible.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f012"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F013",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Motor overload: triggered by excessive motor current",
   "what_to_do": "Check the configuration of the motor thermal protection and the motor load.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f013"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F014",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "1 output phase loss: loss of one phase on the drive output",
   "what_to_do": "Check the connections from the drive to the motor; with a downstream contactor, make sure the connection, cable and contactor are right.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f014"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F015",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "3 output phases loss: motor not connected, motor power below 6% of the rated drive current, output contactor open, or transient instability in the motor current",
   "what_to_do": "Check the connections from the drive to the motor. To test without a matching motor, set Output Phase loss detection 605 = 00. Check IR compensation 310, Rated motor voltage 304 and Rated motor current 305, then perform Auto-tuning 318.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f015"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F016",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Main overvoltage: line voltage too high (10% over the maximum at power on, or 20% over the maximum with no run command) or disturbed mains supply",
   "what_to_do": "Turn off the drive; check and adjust the line voltage; power on again once it is back to nominal. If F016 comes and goes, R1 assignment 205.0 can be set to 01 and connected to upstream protection.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f016"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F017",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Input phase loss: drive incorrectly supplied or a fuse blown, one phase failed, 3-phase ATV310 on a single-phase supply, or unbalanced load (only operates with the drive on load)",
   "what_to_do": "Check the power connection and the fuses; use a 3-phase supply. Reporting can be disabled with Input Phase loss detection 606 = 00.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f017"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F021",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Load short circuit: short circuit at the drive output (also detected at the run or DC injection command if IGBT Test 608 = 01)",
   "what_to_do": "Check the cables connecting the drive to the motor and the condition of the motor insulation.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f021"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F022",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Modbus interruption: interrupted communication on the Modbus network",
   "what_to_do": "Check the bus connections and the time-out (Modbus time out 704); refer to the Modbus user manual.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f022"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F024",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "HMI communication: communication interruption with the external display terminal",
   "what_to_do": "Check the terminal connection.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f024"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F026",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "PI feedback fault: PID feedback below the lower limit",
   "what_to_do": "Verify the PID function feedback, PID feedback supervision 59.25 and time delay 59.23.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f026"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F027",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "IGBT overheat: drive overheated; IGBT internal temperature too high for the ambient temperature and load",
   "what_to_do": "Check the size of the load/motor/drive; reduce the switching frequency 315; wait for the drive to cool down before restarting.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f027"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F029",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Process underload fault: motor current below the underload threshold 211 for longer than the time delay 210",
   "what_to_do": "Check that the drive parameters and the application process are compatible.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f029"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F033",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "AI1 current loss: AI1 is set as a current input, its 0% scaling 204.1 is above 3 mA, and the input current is below 2 mA",
   "what_to_do": "Check the terminal connection.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f033"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F030",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Undervoltage: line supply too low, or transient voltage dip",
   "what_to_do": "Check the voltage and the parameters in the Undervoltage phase loss menu 607-.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f030"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F031",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Incorrect configuration: HMI block replaced by one configured on a drive with a different rating, or customer parameters inconsistent",
   "what_to_do": "Return to factory settings or retrieve the backup configuration, if it is valid. If the fault remains after factory settings, contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f031"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F032",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Invalid configuration: the configuration loaded through the bus or network is inconsistent, or the upload was interrupted or not finished",
   "what_to_do": "Check the configuration loaded previously; load a compatible configuration.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f032"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "F034",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Download invalid configuration: the drive found an invalid configuration while saving parameters or restoring factory settings",
   "what_to_do": "Power cycle the drive; restore the factory setting. If the fault remains, contact your local Schneider Electric representative.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-f034"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "ANF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Load slipping: the difference between the output frequency and the speed feedback is not correct",
   "what_to_do": "Check the motor, gain and stability parameters; add a braking resistor; check the size of the motor/drive/load; check the encoder coupling and wiring; check the parameter settings.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-anf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "ASF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Angle error: during the phase-shift angle measurement, a motor phase is disconnected or the motor inductance is too high",
   "what_to_do": "Check the motor phases and the maximum current allowed by the drive.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-asf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "BLF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Brake control error: brake release current not reached; the manual also lists the brake engage frequency threshold BEN (only regulated when brake logic control is assigned)",
   "what_to_do": "Check the drive/motor connection and the motor windings; check the IBR and IRD settings; apply the recommended settings for BEN.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-blf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "BRF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Brake feedback error: the brake feedback contact does not match the brake logic, or the brake does not stop the motor quickly enough",
   "what_to_do": "Check the feedback circuit and the brake logic control circuit; check the mechanical state of the brake and the brake linings.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-brf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CFF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Incorrect configuration: option module changed or removed, control block replaced by one from a drive with a different rating, or configuration inconsistent",
   "what_to_do": "Check that there are no module errors; return to factory settings (FCS-) or retrieve the backup configuration, if it is valid.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cff-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CFI",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Invalid configuration: the configuration loaded through the bus or network is inconsistent",
   "what_to_do": "Check the configuration loaded previously; load a compatible configuration.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cfi-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CFI2",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Configuration transfer error: the configuration loaded through the bus or network is inconsistent",
   "what_to_do": "Check the configuration loaded previously; load a compatible configuration.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cfi2-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CNF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Fieldbus module communication interruption",
   "what_to_do": "Check the environment (electromagnetic compatibility), the wiring and the time-out; replace the option module. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cnf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "COF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "CANopen communication interruption",
   "what_to_do": "Check the communication bus and the time-out; refer to the CANopen user manual.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cof"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CRF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Precharge capacitor error: charging relay control error or charging resistor damaged",
   "what_to_do": "Turn the drive off and on again; check the internal connections. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-crf1-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CSF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Channel switching error: switch to channels that are not valid",
   "what_to_do": "Check the function parameters.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-csf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "DLF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Dynamic load error: abnormal load variation",
   "what_to_do": "Check that the load is not blocked by an obstacle. Removing the run command causes a reset.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-dlf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "EEF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "EEprom control error: internal memory error, control block",
   "what_to_do": "Check the environment (electromagnetic compatibility); turn off, reset, return to factory settings. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-eef1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "EEF2",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "EEprom power error: internal memory error, power board",
   "what_to_do": "Check the environment (electromagnetic compatibility); turn off, reset, return to factory settings. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-eef2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "EPF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "External error: event triggered by an external device",
   "what_to_do": "Check the device which caused the trip and reset.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-epf1-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "EPF2",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Fieldbus external error: event triggered by a communication network",
   "what_to_do": "Check the cause of the trip and reset.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-epf2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "FBE",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Function block error",
   "what_to_do": "See [FB Error] FBFT for details.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-fbe"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "FBES",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Function block stop error: function blocks were stopped while the motor was running",
   "what_to_do": "Check the [FB Motor Stop Type] FBSM configuration.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-fbes"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "FCF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Output contactor closed: the output contactor stays closed although the opening conditions are met",
   "what_to_do": "Check the contactor and its wiring, and the feedback circuit.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-fcf1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "FCF2",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Output contactor opened: the output contactor stays open although the closing conditions are met",
   "what_to_do": "Check the contactor and its wiring, and the feedback circuit.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-fcf2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "HCF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Boards compatibility: Boards pairing (PPI-) is configured and a drive card has been changed",
   "what_to_do": "If a card is faulty, reinsert the original card; if the card was changed on purpose, confirm with the Pairing password PPI.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-hcf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "HDF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "IGBT desaturation: short circuit or grounding at the drive",
   "what_to_do": "Check the cables connecting the drive to the motor, and the motor insulation.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-hdf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "ILF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal link error: communication interruption between the option module and the drive",
   "what_to_do": "Check the environment (electromagnetic compatibility) and the connections; replace the option module. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ilf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 1 (Rating): the power board is different from the board stored",
   "what_to_do": "Check the reference of the power board.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INF2",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 2 (Soft): the power board is incompatible with the control block",
   "what_to_do": "Check the reference of the power board and its compatibility.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf2-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INF3",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 3 (Intern Comm): communication interruption between the internal cards",
   "what_to_do": "Check the internal connections. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf3-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INF4",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 4 (Manufacturing): internal data inconsistent",
   "what_to_do": "Re-calibrate the drive (done by Schneider Electric Product Support).",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf4-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INF6",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 6 (Option): the option installed in the drive is not recognized",
   "what_to_do": "Check the reference and compatibility of the option, and that it is well inserted.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf6"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INF9",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 9 (Measure): the current measurements are incorrect",
   "what_to_do": "Replace the current sensors or the power board. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-inf9-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INFA",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 10 (Mains): the input stage is not operating correctly",
   "what_to_do": "Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-infa"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INFB",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 11 (Temperature): the drive temperature sensor is not operating correctly",
   "what_to_do": "Replace the drive temperature sensor. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-infb-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "INFE",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Internal error 14 (CPU): internal microprocessor error",
   "what_to_do": "Turn off and reset. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-infe-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "LCF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Input contactor error: the drive is not turned on even though Mains V. time out LCT has elapsed",
   "what_to_do": "Check the contactor and its wiring, the time-out, and the supply mains/contactor/drive connection.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-lcf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "LFF3",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "AI3 4-20 mA loss: loss of the 4-20 mA reference on analog input AI3",
   "what_to_do": "Check the connection on the analog inputs.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-lff3"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OBF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "DC bus overvoltage: braking too sudden or driving load, or supply voltage too high",
   "what_to_do": "Increase the deceleration time; install a braking resistor if necessary; activate Dec.Ramp Adapt BRA if compatible with the application; check the supply voltage.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-obf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OCF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Overcurrent: parameters in the SET- and DRC- menus not correct, inertia or load too high, or mechanical locking",
   "what_to_do": "Check the parameters, the size of the motor/drive/load and the state of the mechanism; decrease Current Limitation CLI; increase the switching frequency.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ocf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OHF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Drive overheating: drive temperature too high",
   "what_to_do": "Check the motor load, the drive ventilation and the ambient temperature. Wait for the drive to cool down before restarting.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ohf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OLC",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Process overload",
   "what_to_do": "Check and remove the cause of the overload; check the parameters of the Process overload OLD- function.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-olc-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OLF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Motor overload: triggered by excessive motor current",
   "what_to_do": "Check the setting of the motor thermal protection and the motor load. Wait for the motor to cool down before restarting.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-olf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OPF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Single output phase loss: loss of one phase at the drive output",
   "what_to_do": "Check the connections from the drive to the motor.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-opf1-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OPF2",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Output phase loss: motor not connected or motor power too low, output contactor open, or instantaneous instability in the motor current",
   "what_to_do": "Check the connections from the drive to the motor. If an output contactor is used, set Output phase loss OPL to OAC. To test without a matching motor, set OPL = NO. Check UFR, UNS and NCR and perform Autotuning TUN.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-opf2-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OSF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Supply mains overvoltage: supply voltage too high, or disturbed mains supply",
   "what_to_do": "Check the supply voltage.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-osf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "OTFL",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "DI6=PTC overheat: overheating of the PTC probes detected on input DI6",
   "what_to_do": "Check the motor load, motor size and motor ventilation; wait for the motor to cool before restarting; check the type and state of the PTC probes.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-otfl"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "PHF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Input phase loss: drive incorrectly supplied or a fuse blown, one phase missing, 3-phase ATV320 on a single-phase supply, or unbalanced load (only operates with the drive on load)",
   "what_to_do": "Check the power connection and the fuses; use a 3-phase supply. The error can be disabled with InPhaseLoss Assign IPL = NO.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-phf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "PTFL",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "DI6=PTC probe error: the PTC probe on input DI6 is open or short-circuited",
   "what_to_do": "Check the PTC probe and the wiring between it and the motor/drive.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ptfl"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SAFF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Safety function error: debounce time exceeded, SS1 threshold exceeded, incorrect configuration, or SLS type overspeed",
   "what_to_do": "Check the safety functions configuration and the ATV320 Integrated Safety Functions manual. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-saff"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Motor short circuit: short circuit or grounding at the drive output",
   "what_to_do": "Check the cables connecting the drive to the motor, and the motor insulation; connect chokes in series with the motor; check the speed loop and brake adjustment; increase Time to restart TTR. The remedy list gives both reduce and increase the switching frequency.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf1-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF3",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Ground short circuit: significant earth leakage current at the drive output if several motors are connected in parallel",
   "what_to_do": "Check the cables connecting the drive to the motor, and the motor insulation; reduce the switching frequency; connect chokes in series with the motor; check the speed loop and brake adjustment; increase Time to restart TTR.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf3-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF4",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "IGBT short circuit: power component error",
   "what_to_do": "Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf4-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SCF5",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Motor short circuit: short circuit at the drive output",
   "what_to_do": "Check the cables connecting the drive to the motor, and the motor insulation. Contact Schneider Electric Product Support.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-scf5-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SLF1",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Modbus communication interruption",
   "what_to_do": "Check the communication bus and the time-out; refer to the Modbus user manual.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-slf1-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SLF2",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "PC communication interruption: communication interruption with the PC software",
   "what_to_do": "Check the PC software connecting cable and the time-out.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-slf2-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SLF3",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "HMI communication interruption: with the graphic display terminal or remote display terminal",
   "what_to_do": "Check the terminal connection and the time-out.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-slf3-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SOF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Motor overspeed: instability or driving load too high, downstream contactor not closed before the Run command, or overspeed threshold (110% of Max Frequency TFR) reached",
   "what_to_do": "Check the motor, gain and stability parameters; add a braking resistor; check the size of the motor/drive/load; check the Frequency meter FQF- settings if used; close the motor contacts before the Run command; Schneider recommends TFR at least 110% of High Speed HSP.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-sof-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SPF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Encoder feedback loss: signal on the Pulse input missing (if used for speed measurement), or encoder feedback signal missing",
   "what_to_do": "Check the input cable wiring and the detector, the encoder configuration parameters, the wiring between the encoder and the drive, and the encoder.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-spf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "SSF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Torque limitation error: switch to torque or current limitation",
   "what_to_do": "Check for mechanical problems; check the parameters of Torque limitation TOL- and Torque or I limit detect TID-.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ssf"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "TJF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "IGBT overheating: drive overheated",
   "what_to_do": "Check the size of the load/motor/drive; reduce the switching frequency. The manual then says: \"Wait for the motor to cool before restarting.\"",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-tjf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "TNF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Autotuning error: special motor or motor power not suitable for the drive, motor not connected, or motor not stopped",
   "what_to_do": "Check that the motor and drive are compatible, that the motor is present and stopped during auto-tuning; if an output contactor is used, close it during auto-tuning.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-tnf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "ULF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Process underload",
   "what_to_do": "Check and remove the cause of the underload; check the parameters of the Process underload ULD- function.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ulf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "USF",
   "also_shown_as": "",
   "model": "ATV320",
   "meaning": "Supply mains undervoltage: supply mains too low, or transient voltage dip",
   "what_to_do": "Check the voltage and the parameters of Undervoltage handling USB-.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-usf-2"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "InIt",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "Initializing: the microcontroller is initializing and searching for the communication configuration (not a fault)",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-init"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "COM.E",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "Communication error (flashing): 50 ms time-out. ATV12 and ATV310 manuals: shown after 220 retry attempts; ATV320 manual: after 20 attempts",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-com-e"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "A-17",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "Key alarm (flashing): a key held down for more than 10 seconds, keypad (membrane switch) disconnected, or keypad woken up while a key is pressed",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-a-17"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "cLr",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "Confirm fault reset (flashing): shown when the STOP key is pressed while there is a fault (ATV320: when the remote display terminal is the active command channel)",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-clr"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "dEU.E",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "Drive mismatch (flashing): the drive brand does not match the remote display terminal brand",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-deu-e"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "rOM.E",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "ROM abnormality (flashing): the terminal found a ROM problem by checksum calculation",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-rom-e"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "rAM.E",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "RAM abnormality (flashing): the terminal found a RAM problem",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-ram-e"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "CPU.E",
   "also_shown_as": "",
   "model": "ATV12, ATV310, ATV320",
   "meaning": "Other fault (flashing): other detected fault (shown on the remote display terminal)",
   "what_to_do": "",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-cpu-e"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "nSt",
   "also_shown_as": "",
   "model": "ATV12, ATV320",
   "meaning": "Not a fault: freewheel stop. Shown when the Freewheel stop input is not powered, or when control is on Modbus/fieldbus and the bus has not sent a command yet",
   "what_to_do": "Normal. Check the logic input assignment (ATV12: COnF/FULL/FUn-/Stt-), or wait for the bus to send a command.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-nst"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "FSt",
   "also_shown_as": "",
   "model": "ATV12, ATV320",
   "meaning": "Not a fault: fast stop. Shown when the Fast stop input is not powered",
   "what_to_do": "Normal. Check the logic input assignment (ATV12: COnF/FULL/FUn-/Stt-).",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-fst"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "rdY",
   "also_shown_as": "",
   "model": "ATV12",
   "meaning": "Not a fault: shown with the Fast stop/Freewheel functions. The ATV12 manual's sentence reads \"it will display rdY en freewheel stop\"; the ATV310 manual's matching sentence says this code shows at the end of a freewheel stop.",
   "what_to_do": "Normal. Check the logic input assignment (COnF/FULL/FUn-/Stt-) and that the run command input is active.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-rdy"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "502.1",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Not a fault: freewheel stop. Shown when the Freewheel stop input is not powered, or when control is on Modbus and the bus has not sent a command yet",
   "what_to_do": "Normal. Check the logic input assignment in COnF/FULL/500-/502-, or wait for the bus to send a command.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-502-1"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "--01",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Not a fault: fast stop mode",
   "what_to_do": "Normal. Check the logic input assignment in COnF/FULL/500-/502-.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-01"
  },
  {
   "appliance": "vfd",
   "brand": "Schneider Electric",
   "code": "--00",
   "also_shown_as": "",
   "model": "ATV310",
   "meaning": "Not a fault: shown at the end of a freewheel stop",
   "what_to_do": "Normal. Check that the run command input is active for the selected control mode.",
   "source": "https://download.se.com/files?p_Doc_Ref=BBV28581&p_enDocType=User+guide&p_File_Name=ATV12-user-manual-EN-BBV28581-06.pdf https://download.se.com/files?p_Doc_Ref=EAV94277&p_enDocType=User+guide&p_File_Name=ATV310-user-manual-EN-EAV94277-12.pdf https://download.se.com/files?p_Doc_Ref=NVE41295&p_enDocType=User+guide&p_File_Name=ATV320_Programming_Manual_EN_NVE41295_06.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/schneider/#code-00"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F1",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Overcurrent: motor power (P0307) does not match converter power (r0206), motor lead short circuit, or earth fault",
   "what_to_do": "Check P0307 matches r0206, cable length limits, motor cable and motor for short circuits or earth faults, motor parameters and stator resistance (P0350), that the motor is not obstructed or overloaded. Increase ramp-up time (P1120), reduce starting boost (P1312).",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f1"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F2",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Overvoltage: main supply voltage too high, or motor in regenerative mode",
   "what_to_do": "Check supply voltage (P0210) is within rating plate limits, ramp-down time (P1121) matches load inertia, braking power within limits, Vdc controller (P1240) enabled and set properly. Higher inertia needs longer ramp times, otherwise a braking resistor.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f2"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F3",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Undervoltage: main supply failed, or shock load outside specified limits",
   "what_to_do": "Check supply voltage.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f3"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F4",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Converter overtemperature: converter overloaded, poor ventilation, pulse frequency too high, surrounding temperature too high, or fan not working",
   "what_to_do": "Check load or load cycle, that P0307 matches r0206, pulse frequency at default, surrounding temperature, and that the fan turns when the converter runs.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f4"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F5",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Converter I2t: converter overloaded, load cycle too demanding, or motor power (P0307) exceeds converter power (r0206)",
   "what_to_do": "Load cycle must be within specified limits; P0307 must match r0206. F5 cannot be cleared until r0036 is lower than P0294.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f5"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F6",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Chip temperature rise exceeds critical levels: load at start-up or load step too high, or ramp-up too fast",
   "what_to_do": "Check load and load steps, increase ramp-up time (P1120), P0307 must match r0206. Siemens says P0290 = 0 or 2 prevents F6.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f6"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F11",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Motor overtemperature: motor overloaded (can also occur on small motors run below 15 Hz with motor temperature within limits)",
   "what_to_do": "Check load, P0626–P0628 and P0604. For small motors below 15 Hz: if motor current is within nameplate current and motor temperature is within limits, set P0335 = 1.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f11"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F12",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Converter temperature signal lost: wire breakage of heat sink temperature sensor",
   "what_to_do": "Contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f12"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F20",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "DC ripple too high, commonly caused by loss of one of the mains input phases",
   "what_to_do": "Check the mains supply wiring.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f20"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F23",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Output current ripple too high: output phase missing or high motor vibration",
   "what_to_do": "Check output wiring, motor mechanical vibration, and the converter response setting P0296.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f23"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F26",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Internal error",
   "what_to_do": "Power-cycle converter. Contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f26"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F35",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Maximum number of auto restart attempts (P1211) exceeded",
   "what_to_do": "Increase the number of restart attempts (P1211).",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f35"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F41",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Motor data identification failure",
   "what_to_do": "r0949 = 0: is the motor connected? r0949 = 1–49: are motor data P0304–P0311 correct? Check star or delta motor wiring.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f41"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F51",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Parameter EEPROM fault: read or write failure, or EEPROM full (too many parameters changed)",
   "what_to_do": "Power-cycle. If that does not clear it: factory reset (P0970 = 31) and new parameterization. If EEPROM is full, set some parameters back to default, then power-cycle. Otherwise change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f51"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F52",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Converter software fault: read failure for converter information or invalid data",
   "what_to_do": "Power-cycle converter. Contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f52"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F60",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Asic timeout: internal communications failure",
   "what_to_do": "If sporadic (EMC problems): improve EMC, use EMC filter. If it appears immediately at power-on and ON command: contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f60"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F61",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "SD card parameter cloning failed",
   "what_to_do": "Depends on r0949: use a FAT16/FAT32 SD card, check the card is not full, put the correct file in /USER/SINAMICS/DATA, or recreate the file.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f61"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F62",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Parameter cloning contents invalid (file exists but contents not valid)",
   "what_to_do": "Recopy and make sure the operation completes.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f62"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F63",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Parameter cloning contents incompatible (file from a different converter type)",
   "what_to_do": "Clone from a compatible converter type.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f63"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F64",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Converter attempted an automatic clone during startup but no Clone00.bin in /USER/SINAMICS/DATA",
   "what_to_do": "If automatic clone is needed, insert the SD card with the correct file and power-cycle. If not, remove the card if not needed and power-cycle, and reset P8458 = 0 and power-cycle. Cleared only by a power-cycle.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f64"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F70",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "I/O Extension Module communication fault",
   "what_to_do": "Reconnect the module and check it works. Acknowledge the fault. If it persists, replace the module.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f70"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F71",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "USS setpoint fault (on RS232): no setpoint values during telegram off time",
   "what_to_do": "Check USS master on RS232.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f71"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F72",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "USS/MODBUS setpoint fault (on RS485): no setpoint values during telegram off time",
   "what_to_do": "Check USS/MODBUS master on RS485.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f72"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F80",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Signal lost on analog input: broken wire or signal out of limits",
   "what_to_do": "Check the wiring and whether analog inputs exceed voltage and current limits. Contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f80"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F85",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "External fault triggered via control word 2, bit 13",
   "what_to_do": "Check P2106. Disable control word 2 bit 13 as command source, or disable the terminal input for fault trigger.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f85"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F100",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Watchdog reset: software error",
   "what_to_do": "Contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f100"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F101",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Stack overflow: software error or processor failure",
   "what_to_do": "Contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f101"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F200",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Script error: internal converter script stopped because of script errors",
   "what_to_do": "Check the script and correct it.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f200"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F221",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "PID feedback below minimum value (P2268)",
   "what_to_do": "Change P2268 or adjust feedback gain.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f221"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F222",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "PID feedback above maximum value (P2267)",
   "what_to_do": "Change P2267 or adjust feedback gain.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f222"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F350",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Configuration vector for the converter failed (hardware does not match programmed configuration; r0949 = 13: wrong power module fitted)",
   "what_to_do": "Internal failures cannot be fixed. r0949 = 13: make sure the right power module is fitted. Needs a power-cycle to acknowledge.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f350"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F395",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Acceptance test/confirmation pending: after a startup clone (or faulty EEPROM read) the parameter set must be checked",
   "what_to_do": "Check the current parameter set and confirm it by clearing the fault.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f395"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F410",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Cavitation protection failure: conditions exist for pump cavitation damage (fluid not flowing enough)",
   "what_to_do": "If cavitation is not occurring, reduce the threshold P2361 or increase the cavitation protection delay. Make sure sensor feedback works.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f410"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "F452",
   "also_shown_as": "",
   "model": "SINAMICS V20 (fault)",
   "meaning": "Load monitoring trip: load conditions indicate belt failure or mechanical fault (r0949 = 0 low, 1 high torque/speed)",
   "what_to_do": "Check for breakage, seizure or obstruction of the drive train, lubricate if required, and check P2182–P2192 settings.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-f452"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A501",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Current limit: motor power does not match converter power, motor leads too long, earth faults, or small motor (120 W) under FCC at light load",
   "what_to_do": "See F1. Use V/f operation for very small motors.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a501"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A502",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Overvoltage limit reached; can occur during ramp down if the Vdc controller is disabled (P1240 = 0)",
   "what_to_do": "If shown permanently, check converter input voltage.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a502"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A503",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Undervoltage limit: main supply failed, or supply and DC-link voltage (r0026) below specified limit",
   "what_to_do": "Check main supply voltage.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a503"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A504",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Converter overtemperature: heat sink or chip junction temperature warning level exceeded, so pulse frequency and/or output frequency is reduced (P0290)",
   "what_to_do": "Check surrounding temperature, load conditions and load steps, and that the fan turns when running. r0037[0] = heat sink, r0037[1] = chip junction temperature.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a504"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A505",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Converter I2t warning level exceeded; current will be reduced if P0610 = 1",
   "what_to_do": "Check the load cycle is within specified limits.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a505"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A506",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "IGBT junction temperature rise warning: heat sink to IGBT junction temperature difference exceeds warning limits",
   "what_to_do": "Check load steps and shock loads are within limits.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a506"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A507",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Converter temperature signal lost: heat sink temperature signal loss, sensor may have fallen off",
   "what_to_do": "Contact service department or change converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a507"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A511",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Motor overtemperature I2t: motor overloaded, or load cycles or load steps too high",
   "what_to_do": "Check P0604, P0625, nameplate data (quick commissioning, motor identification P1900 = 2), motor weight P0344; P0626–P0628 for non-Siemens motors.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a511"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A523",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Output current ripple too high: loss of one output phase or high motor vibration",
   "what_to_do": "Check output wiring and motor mechanical vibration.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a523"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A535",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Braking resistor overload: braking energy too large or resistor not suited",
   "what_to_do": "Reduce braking energy, or use a braking resistor with a higher rating.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a535"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A541",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Motor data identification active (P1900 selected or running)",
   "what_to_do": "Complete the motor data identification.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a541"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A600",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "RTOS overrun warning: internal time slice overrun",
   "what_to_do": "Contact service department.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a600"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A910",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Vdc_max controller de-activated: supply voltage (P0210) permanently too high, motor driven by an active load, or very high load inertia when ramping down",
   "what_to_do": "Input voltage must be within range, load must match, in some cases apply a braking resistor.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a910"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A911",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Vdc_max controller active: keeping DC-link voltage (r0026) below r1242",
   "what_to_do": "Check supply voltage is within rating plate limits and ramp-down time (P1121) matches load inertia; otherwise a braking resistor.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a911"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A912",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Vdc_min controller active: DC-link voltage (r0026) fell below r1246; motor energy used to buffer it, so the converter decelerates. Can also occur on fast ramp-ups",
   "what_to_do": "Check converter input voltage. If it activates during ramp-up, increase ramp-up time (P1120). Check shock load (see F3).",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a912"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A921",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Analog output parameters not set properly (P0777 and P0779 identical)",
   "what_to_do": "Set P0777 and P0779 to different values; settings must match the analog output type.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a921"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A922",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "No load applied to converter; some functions may not work as normal",
   "what_to_do": "Check that the motor is connected to the converter.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a922"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A923",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Both JOG left and JOG right requested (P1055/P1056); output frequency frozen",
   "what_to_do": "Do not press JOG right and left at the same time.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a923"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A930",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Cavitation protection warning: conditions exist for possible cavitation damage",
   "what_to_do": "See F410.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a930"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A936",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "PID autotuning active (P2350 selected or running)",
   "what_to_do": "Disappears when PID autotuning has finished.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a936"
  },
  {
   "appliance": "vfd",
   "brand": "Siemens",
   "code": "A952",
   "also_shown_as": "",
   "model": "SINAMICS V20 (alarm)",
   "meaning": "Load monitoring warning: load conditions indicate belt failure or mechanical fault",
   "what_to_do": "See F452.",
   "source": "https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf https://support.industry.siemens.com/cs/document/109977897/",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/vfd/siemens/#code-a952"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E2",
   "also_shown_as": "shown as E 2",
   "model": "Adonia i, Monza Slim i",
   "meaning": "Water temperature reached 90 °C",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e2"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E3",
   "also_shown_as": "shown as E 3",
   "model": "Adonia i, Monza Slim i",
   "meaning": "NTC temperature sensor open circuit (no voltage across the sensor)",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e3"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E4",
   "also_shown_as": "shown as E 4",
   "model": "Adonia i, Monza Slim i",
   "meaning": "NTC temperature sensor short circuited (maximum voltage across the sensor, nearly 5 V)",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e4"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E5",
   "also_shown_as": "shown as E 5",
   "model": "Adonia i, Monza Slim i",
   "meaning": "Dry heating detected: heating cuts off when the geyser senses a high temperature rise rate without water",
   "what_to_do": "Switch off at the wall. Make sure the inlet valve is open and the tank is full of water, then call Havells service. Never switch the geyser on without water: Havells says it damages the heating element.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e5"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E2",
   "also_shown_as": "",
   "model": "Orizzonte (15 L, 25 L)",
   "meaning": "Overheating or NTC temperature sensor short circuit",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e2-2"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E3",
   "also_shown_as": "",
   "model": "Orizzonte (15 L, 25 L)",
   "meaning": "NTC temperature sensor open circuit",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e3-2"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E01",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Heating surface not detected by the circuit",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e01"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E02",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Coil installation is abnormal",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e02"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E03",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Input voltage is outside the range of 180 V to 265 V",
   "what_to_do": "Switch the geyser off at the wall. Havells' table says the input voltage is outside 180 V to 265 V. If the code stays or keeps coming back, call Havells service. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e03"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E04",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Water temperature sensor problem",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e04"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E05",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Water temperature above 90 °C",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e05"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E06",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Open or short circuit in the electronic circuit",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e06"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E07",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Temperature is too high in the electronic circuit",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e07"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E08",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "Communication between the power PCB and the display PCB is abnormal",
   "what_to_do": "Switch the geyser off at the wall and call Havells service. Havells' manual says: if you see any abnormal operation, switch off the main power and contact customer care. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e08"
  },
  {
   "appliance": "geyser",
   "brand": "Havells",
   "code": "E12",
   "also_shown_as": "",
   "model": "Magnatron (15 L, 25 L)",
   "meaning": "No water inside the tank",
   "what_to_do": "Switch off at the wall. Havells' manual says to keep the inlet valve open and, before switching on again, to make sure the drain plug lever on the safety valve is reset and screwed and to fill the geyser until clean water flows from the hot tap. If the code stays, call Havells service. Do not open the geyser.",
   "source": "https://havells.com/media/wysiwyg/Manuals/Adonia_I_IM_4_Color.pdf https://havells.com/media/wysiwyg/Manuals/Monza_Slim_i_IM.pdf https://havells.com/media/wysiwyg/Manuals/Orizzonte_IM.pdf https://havells.com/media/wysiwyg/Manuals/Magnatron_IM.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/geyser/havells/#code-e12"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "E02",
   "also_shown_as": "",
   "model": "Perk Star hot & cold dispenser with RO",
   "meaning": "Abnormal working: the system kept producing water for 16 hours without stopping. It stops producing water and sterilizing.",
   "what_to_do": "KENT's table says: power on again after troubleshooting. If E02 comes back, call KENT service.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-e02"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "E05",
   "also_shown_as": "",
   "model": "Perk Star hot & cold dispenser with RO",
   "meaning": "Abnormal heating: it heated for 1 hour but the temperature did not go above 50 °C. Heating stops.",
   "what_to_do": "KENT's table says: power on again after troubleshooting. If E05 comes back, call KENT service (the troubleshooting table, under 'water does not come out hot', lists a damaged heating element or hot tank thermostat).",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-e05"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "E07",
   "also_shown_as": "",
   "model": "Perk Star hot & cold dispenser with RO",
   "meaning": "Water leakage: the leakage sensor detected water for 15 seconds. The system shuts down.",
   "what_to_do": "Unplug the dispenser and call KENT service. KENT's table says to replug only after troubleshooting (the leak is found and fixed). Do not open the unit.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-e07"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "E09",
   "also_shown_as": "",
   "model": "Perk Star hot & cold dispenser with RO",
   "meaning": "Hot water temperature sensor (NTC) malfunction: its reading was outside the limit for 15 seconds. Heating stops.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-e09"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "E18",
   "also_shown_as": "",
   "model": "Perk Star hot & cold dispenser with RO",
   "meaning": "Cold water temperature sensor (NTC) malfunction: its reading was outside the limit for 15 seconds (KENT's table says heating stops).",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-e18"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "E22",
   "also_shown_as": "",
   "model": "Perk Star hot & cold dispenser with RO",
   "meaning": "Abnormal liquid level switch position. The system shuts down.",
   "what_to_do": "Unplug and plug in again. If E22 comes back, call KENT service (the troubleshooting table, under 'tank does not fill', lists a damaged level switch or electronic board).",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-e22"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "E35",
   "also_shown_as": "",
   "model": "Perk Star hot & cold dispenser with RO",
   "meaning": "Abnormal communication between the display board and the system. The system shuts down.",
   "what_to_do": "Unplug, plug in again and wait for communication. If E35 stays, call KENT service.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-e35"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "UV fail",
   "also_shown_as": "screen warning; one beep for UV lamp, blinking sign with two beeps for UV LED",
   "model": "Ace / Grand / Supreme Star-B",
   "meaning": "UV lamp or UV LED failure. With a lamp failure the purifier stops purifying water until the UV lamp is replaced.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-uv-fail"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Tank UV fail",
   "also_shown_as": "blinking screen warning with a long beep",
   "model": "Ace / Supreme / Sterling IoT",
   "meaning": "Tank UV LED failure",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-tank-uv-fail"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Inline UV fail",
   "also_shown_as": "screen warning with a continuous beep",
   "model": "Ace / Supreme / Sterling IoT",
   "meaning": "Inline UV failure. The purifier stops purifying water until the inline UV is replaced.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-inline-uv-fail"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Replace filter",
   "also_shown_as": "screen message with a continuous buzzer; IoT: Change Filters",
   "model": "Star-B and IoT models",
   "meaning": "Filter life is used up. The purifier stops purifying water until the filters are replaced.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-replace-filter"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Change membrane",
   "also_shown_as": "screen message with a continuous buzzer",
   "model": "Ace / Supreme / Sterling IoT",
   "meaning": "RO membrane life is used up. The purifier stops purifying water until it is replaced.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-change-membrane"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Low RO flow",
   "also_shown_as": "warning sign; IoT: Change Membrane and LPH sign",
   "model": "Star-B and IoT models",
   "meaning": "The RO membrane's capacity has dropped. The purifier keeps working until the membrane fails.",
   "what_to_do": "Call KENT customer care and ask for a membrane replacement.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-low-ro-flow"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "No water input",
   "also_shown_as": "screen warning",
   "model": "Star-B and IoT models",
   "meaning": "No water is coming in. The purifier switches off and stays off until the water supply is restored.",
   "what_to_do": "Check that the water supply to the purifier is on. On Star-B models the purifier does not start if inlet pressure is below 0.3 kg/cm². If water is coming and the warning stays, call KENT service.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-no-water-input"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Mineral content low",
   "also_shown_as": "bar in yellow (Star-B) or orange (IoT) zone, with a warning sign",
   "model": "Star-B and IoT models",
   "meaning": "The TDS (mineral content) of the purified water is below the permissible range.",
   "what_to_do": "KENT's Star-B manual says: call customer care or log in to the app.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-mineral-content-low"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Mineral content high",
   "also_shown_as": "bar in red zone, with a warning sign",
   "model": "Star-B and IoT models",
   "meaning": "The TDS (mineral content) of the purified water is above the permissible range.",
   "what_to_do": "KENT's Star-B manual says: call customer care or log in to the app.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-mineral-content-high"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "4 short beeps",
   "also_shown_as": "every two seconds, for 30 seconds, repeats every 2 hours of use",
   "model": "Supreme-B, Excell+, Grand Plus, Maxx; non-digital",
   "meaning": "Filter change alarm: filters are due for a change (Supreme-B, Excell+, Grand Plus: after 700 hours of use since the last filter change or installation).",
   "what_to_do": "Call a KENT service technician to change the filters. If they are not changed within the next 60 hours of use, the purifier stops working.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-4-short-beeps"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "Continuous beep",
   "also_shown_as": "does not stop",
   "model": "Supreme-B, Excell+, Grand Plus, Maxx; non-digital",
   "meaning": "Filters not changed within 60 hours of the filter change alarm. The purifier has stopped and will not work until the filters are changed.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-continuous-beep"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "1 short beep every 2 seconds",
   "also_shown_as": "UV fail alarm",
   "model": "Grand Plus, Excell+, Maxx, Elixir-1",
   "meaning": "UV lamp failure. On Grand Plus and Maxx the purification process stops.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-1-short-beep-every-2-seconds"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "2 beeps",
   "also_shown_as": "UV LED fail alarm",
   "model": "Grand Plus",
   "meaning": "UV LED failure",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-2-beeps"
  },
  {
   "appliance": "water-purifier",
   "brand": "KENT",
   "code": "UV alarm",
   "also_shown_as": "alarm sound",
   "model": "Smart Plus, Ultra Storage with Active Copper; UV only",
   "meaning": "The UV lamp is not drawing enough current from the power source.",
   "what_to_do": "Switch off the purifier and call a KENT service technician. Do not open the purifier.",
   "source": "https://www.kent.co.in/cdn/shop/files/kent-perk-star-111173.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-grand-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-star-b.pdf https://www.kent.co.in/cdn/shop/files/kent-ace-iot-111197B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-iot-111195B.pdf https://www.kent.co.in/cdn/shop/files/kent-sterling-iot-111185B.pdf https://www.kent.co.in/cdn/shop/files/kent-supreme-b.pdf https://www.kent.co.in/cdn/shop/files/kent-excell-plus-11003.pdf https://www.kent.co.in/cdn/shop/files/Kent-Grand-Plus-11099.pdf https://www.kent.co.in/cdn/shop/files/kent-maxx-user-manual.pdf https://www.kent.co.in/cdn/shop/files/kent-elixir-1-111170.pdf https://www.kent.co.in/cdn/shop/files/kent-smart-plus-111188b.pdf https://www.kent.co.in/cdn/shop/files/kent-ultra-storage-with-active-copper-manual.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/water-purifier/kent/#code-uv-alarm"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "01",
   "also_shown_as": "shown as 01 LOW POWER; a warning, not a fault (Lotus, Simha Plus footnote)",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Low power: input power is low because of weak sunlight or shadow on the panels, panels not in healthy condition, or solar power below the minimum PV power setting. Lotus and Simha Plus mark this as a warning, not a fault.",
   "what_to_do": "Check whether sunlight is weak; if so, wait for proper sunlight. The Lotus and Simha Plus manuals also say to check dust on the panels and the direction of the panels. The installer can lower the minimum input power setting.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-01"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "02",
   "also_shown_as": "shown as 02 DC BUS UNDER VOLTAGE",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "DC bus under voltage: low input power (weak sunlight or shadow on panels), panels not in healthy condition, or a sudden high power draw by the motor because the pump or motor is jammed",
   "what_to_do": "Check whether sunlight is weak and wait for proper sunlight. The Lotus and Simha Plus manuals also say to check dust on the panels and their direction. If the pump or motor may be jammed, the installer should check and clean the motor pump set. The installer can also lower the minimum input power setting.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-02"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "03",
   "also_shown_as": "shown as 03 DC BUS OVER VOLTAGE",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "DC bus over voltage: the DC bus voltage in the drive is more than the set voltage",
   "what_to_do": "The installer should check the number of PV panels connected in series and make sure the voltage is below the limit in the drive's specification sheet. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-03"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "04",
   "also_shown_as": "shown as 04 OUTPUT OVER VOLTAGE",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Output over voltage: the output side voltage is high when the drive is off",
   "what_to_do": "The installer should check that the input is connected at the right place. Shakti's troubleshooting also lists hardware failure: contact customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-04"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "05",
   "also_shown_as": "shown as 05 DRY RUN DETECTED",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Dry run: no water on the suction / inlet side of the pump",
   "what_to_do": "Check that water is available at the pump inlet. For a submersible pump, wait for water to come in. For a surface pump, check the water level in the tank and do the priming properly.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-05"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "06",
   "also_shown_as": "shown as 06 OVER TEMP PROTECTED",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Over temperature: the drive is heating more than expected, or ventilation is poor",
   "what_to_do": "Check the ventilation around the drive and how it is mounted. If it keeps coming, contact Shakti customer care. Do not open the drive.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-06"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "07",
   "also_shown_as": "shown as 07 OVER CURRENT DETECTED",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Over current at output: the output current (RMS) is more than the value set in the drive's factory setup. Causes: wrong rated current set, or the connected load does not match the selected parameters.",
   "what_to_do": "The installer should set the right rated current and check the connected load. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-07"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "08",
   "also_shown_as": "shown as 08 SHORT CIRCUIT TRIP",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Short circuit trip: an internal or output connection is shorted, the voltage is too low, or there was a sudden load",
   "what_to_do": "Switch off. An electrician or installer should find and correct the shorted connection and check the cable insulation (Lotus and Simha Plus manuals: run the drive with the motor disconnected; if it runs, check the motor wires, cable and the motor's megger reading). Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-08"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "09",
   "also_shown_as": "shown as 09 HIGH INRUSH CURRENT",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "High inrush current: sudden increase in load, wrong motor selected, or a cable joint not done properly",
   "what_to_do": "The installer should select the correct motor in the menu and make a proper cable joint. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-09"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "10",
   "also_shown_as": "shown as 10 OUTPUT OPEN CIRCUIT",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Output open circuit: one of the outputs opened while running",
   "what_to_do": "Check that the motor is connected at the drive's output (installer or electrician).",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-10"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "11",
   "also_shown_as": "shown as 11 PMSM START FAIL",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "PMSM start fail: starting torque not enough, or the pump or motor is mechanically jammed",
   "what_to_do": "The installer can increase the torque boost % and INIT_RAMP_TIME_PMSM parameters, and check the pump for a jam.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-11"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "12",
   "also_shown_as": "shown as 12 UNBALANCE FAULT",
   "model": "Nandi, Lotus, Simha Plus solar drives",
   "meaning": "Unbalance fault: one of the three phases is missing",
   "what_to_do": "An electrician or installer should check all three phase connections. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-12"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "01",
   "also_shown_as": "shown as 01 LOW POWER",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Low power: input power is less than the set minimum power (weak sunlight or shadow on panels, panels not healthy, or solar power below the minimum PV power setting)",
   "what_to_do": "Check whether sunlight is weak; if so, wait for proper sunlight. The installer can lower the minimum input power setting.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-01-2"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "02",
   "also_shown_as": "shown as 02 DC BUS OVERVOLTAGE",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "DC bus over voltage: the DC bus voltage is more than the set voltage",
   "what_to_do": "The installer should check the number of PV panels in series and keep the voltage below the specification. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-02-2"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "05",
   "also_shown_as": "shown as 05 DRY RUN DETECTED",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Dry run: no water on the suction / inlet side of the pump",
   "what_to_do": "Check that water is available at the pump inlet. For a submersible pump, wait for water to come in. For a surface pump, check the tank water level and do the priming properly.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-05-2"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "06",
   "also_shown_as": "shown as 06 WRONG MOTOR",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Wrong motor: the wrong type of motor is connected, for example an induction motor instead of PMSM, or the other way round",
   "what_to_do": "The installer should connect the correct motor and change the setting to match it.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-06-2"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "08",
   "also_shown_as": "shown as 08 VFD HIGH INRUSH CURRENT",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "High inrush current: sudden increase in load, wrong motor selected, or a cable joint not done properly",
   "what_to_do": "The installer should select the correct motor in the menu and make a proper cable joint. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-08-2"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "09",
   "also_shown_as": "shown as 09 OUTPUT OPEN CIRCUIT",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Output open circuit: one of the outputs opened while running",
   "what_to_do": "Check that the motor is connected at the output (installer or electrician).",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-09-2"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "18",
   "also_shown_as": "shown as 18 PV OVER VOLTAGE",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "PV over voltage: the average panel (PV) voltage is above 765 V",
   "what_to_do": "The installer should reduce the PV string voltage.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-18"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "19",
   "also_shown_as": "shown as 19 PV UNDER VOLTAGE",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "PV under voltage: the average panel (PV) voltage is below 150 V",
   "what_to_do": "Wait for enough sunshine. If it happens in good sun, the installer should increase the PV string voltage.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-19"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "20",
   "also_shown_as": "shown as 20 USPC OVER TEMP",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Controller over temperature: the controller is heating more than expected, or ventilation is poor",
   "what_to_do": "Check the ventilation and mounting. If it keeps coming, contact Shakti customer care. Do not open the controller.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-20"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "24",
   "also_shown_as": "shown as 24 PEAK TORQUE OVERLOAD",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Peak torque overload: the load torque is above 150%",
   "what_to_do": "Remove the extra load. The installer should select the correct motor in the menu and check the cable joints.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-24"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "25",
   "also_shown_as": "shown as 25 USPC FREQUENCY HIGH",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Output frequency higher than the permissible (settable) range",
   "what_to_do": "The installer should check the connections, the over-frequency limit and rated frequency settings, and the connected load. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-25"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "26",
   "also_shown_as": "shown as 26 USPC FREQUENCY LOW",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Output frequency lower than the permissible (settable) range",
   "what_to_do": "The installer should check the connections, the under-frequency limit and rated frequency settings, and the connected load. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-26"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "27",
   "also_shown_as": "shown as 27 USPC SHORT CIRCUIT",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Short circuit: an internal or output connection is shorted, the voltage is too low, or there was a sudden load",
   "what_to_do": "Switch off. An electrician or installer should correct the shorted connection and check the cable insulation. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-27"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "28",
   "also_shown_as": "shown as 28 USPC VOLTAGE HIGH",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Output voltage high: 4% above rated voltage, or the input is connected to the output",
   "what_to_do": "The installer should check the connections and the connected load. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-28"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "29",
   "also_shown_as": "shown as 29 USPC VOLTAGE LOW",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Output voltage lower than the permissible (settable) range",
   "what_to_do": "Remove extra load. The installer should check the connections and the under-voltage limit setting. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-29"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "31",
   "also_shown_as": "shown as 31 OVER CURRENT",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "Over current: output current is above the over-current value set in the display",
   "what_to_do": "The installer should check the over-current setting. Contact Shakti customer care.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-31"
  },
  {
   "appliance": "solar-pump",
   "brand": "Shakti",
   "code": "32",
   "also_shown_as": "shown as 32 START FAIL PMSM",
   "model": "Kalpavriksha USPC, 2022 manual",
   "meaning": "PMSM start fail: starting torque not enough, or the pump or motor is jammed",
   "what_to_do": "The installer can increase the torque boost % and INIT_RAMP_TIME_PMSM parameters, and check the pump for a jam.",
   "source": "https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Nandi-Ins-Manual_-L5_-18-Nov-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Solar-Simha-Lotus-Drive-L1_07-July-2025.pdf https://shaktipumps.com/wp-content/uploads/2026/04/Shakti-Simha-Plus-Solar-Drive-Manual_L7_25-April-2026.pdf https://shaktipumps.com/wp-content/uploads/2025/04/Shakti_Kalpavriskha_USPC_InsManual_Dec_2022.pdf https://shaktipumps.com/wp-content/uploads/2026/05/Shakti-Kalpavriksha-USPC-_-Ins-Manual-_L4_-20-Nov-2025.pdf",
   "checked": "2026-10-28",
   "url": "https://faultdecode.com/solar-pump/shakti/#code-32"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E1",
   "also_shown_as": "",
   "model": "EON Velvet, Velvet Steam (top load); EON Alpha, Valor, Magnus, Audra Plus, Allure Classic (top load)",
   "meaning": "Water does not flow into the tub within 15 minutes (with beeps for some time)",
   "what_to_do": "Check that the tap is open, the water supply has not stopped, and the supply hose or the metal filter at the water inlet is not blocked (Godrej also says to check the hose is not frozen). Fix the cause, then open and close the lid to restart the washer.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e1"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E2",
   "also_shown_as": "",
   "model": "EON Velvet, Velvet Steam (top load); EON Alpha, Valor, Magnus, Audra Plus, Allure Classic (top load)",
   "meaning": "Water does not drain 10 minutes after the drain starts (with beeps for some time)",
   "what_to_do": "Check that the drain outlet is not too high, the drain hose is placed correctly, not blocked by scraps or fibre, and not too long or bent. Fix the cause, then open and close the lid to restart the washer.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E3",
   "also_shown_as": "",
   "model": "EON Velvet, Velvet Steam (top load)",
   "meaning": "Lid open during spinning (with beeps for some time)",
   "what_to_do": "Close the lid to restart the washer.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e3"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E3",
   "also_shown_as": "",
   "model": "EON Alpha, Valor, Magnus, Audra Plus, Allure Classic (top load)",
   "meaning": "Lid opened while the machine is running (with beeps for some time)",
   "what_to_do": "Close the lid to restart the washer.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e3-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E4",
   "also_shown_as": "",
   "model": "EON Velvet, Velvet Steam (top load); EON Alpha, Valor, Magnus, Audra Plus, Allure Classic (top load)",
   "meaning": "Load unbalance: the machine tried to balance the load automatically twice and it went out of balance a third time",
   "what_to_do": "Check that the machine stands steady, the load is the right size, and the clothes are spread out evenly. Balance the clothes and close the lid to restart.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e4"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EH",
   "also_shown_as": "",
   "model": "EON Velvet, Velvet Steam (top load)",
   "meaning": "Input voltage at the socket is very high, above 290 V (with beeps)",
   "what_to_do": "Unplug the machine to avoid damage and wait until the supply voltage is normal. Get the socket voltage checked.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-eh"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EH",
   "also_shown_as": "",
   "model": "EON Alpha, Valor, Magnus, Audra Plus, Allure Classic (top load)",
   "meaning": "Input voltage at the socket is very high, above 285 V (with beeps)",
   "what_to_do": "Unplug the machine to avoid damage, or wait until the supply voltage is normal. If the error persists, call an authorised technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-eh-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EL",
   "also_shown_as": "",
   "model": "EON Velvet, Velvet Steam (top load)",
   "meaning": "Input voltage at the socket is very low, below 150 V (with beeps)",
   "what_to_do": "Unplug the machine to avoid damage and wait until the supply voltage is normal. Get the socket voltage checked.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-el"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EL",
   "also_shown_as": "",
   "model": "EON Alpha, Valor, Magnus, Audra Plus, Allure Classic (top load)",
   "meaning": "Input voltage at the socket is very low, below 160 V (with beeps)",
   "what_to_do": "Unplug the machine to avoid damage, or wait until the supply voltage is normal. If the error persists, call an authorised technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-el-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EE",
   "also_shown_as": "",
   "model": "EON Velvet, Velvet Steam (top load)",
   "meaning": "Water level sensing error",
   "what_to_do": "Call an authorised technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-ee"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EE",
   "also_shown_as": "",
   "model": "EON Alpha, Valor, Magnus, Audra Plus, Allure Classic (top load)",
   "meaning": "Water level sensing error",
   "what_to_do": "Remove the power plug and put it back after one minute. If the error persists, call an authorised technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-ee-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "H7",
   "also_shown_as": "",
   "model": "EON Velvet Steam; heater versions of Alpha, Magnus, Valor, Allure Classic",
   "meaning": "Water temperature is not rising enough within 45 minutes (with beeps)",
   "what_to_do": "Remove the power plug, put it back after one minute and start the machine. If the error persists, call Godrej customer care (Velvet Steam) or an authorised technician (other heater models).",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-h7"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "H8",
   "also_shown_as": "",
   "model": "EON Velvet Steam; heater versions of Alpha, Magnus, Valor, Allure Classic",
   "meaning": "Heater temperature sensor not working properly (with beeps)",
   "what_to_do": "Remove the power plug, put it back after one minute and start the machine. If the error persists, call Godrej customer care (Velvet Steam) or an authorised technician (other heater models).",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-h8"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "H9",
   "also_shown_as": "",
   "model": "EON Velvet Steam; heater versions of Alpha, Magnus, Valor, Allure Classic",
   "meaning": "Water temperature went above the allowed limit of 70 °C (with beeps)",
   "what_to_do": "Remove the power plug, put it back after 30 minutes and start the machine. If the error persists, call Godrej customer care (Velvet Steam) or an authorised technician (other heater models).",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-h9"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E0",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "Software flash issue",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e0"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E1",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "No water",
   "what_to_do": "Check the water inlet connection.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e1-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E2",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "No water drain",
   "what_to_do": "Check the drain pipe position. If the problem persists, call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e2-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E3",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "Door (lid) open",
   "what_to_do": "Close the lid properly.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e3-3"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E4",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "Unbalance error",
   "what_to_do": "Spread the clothes evenly.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e4-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E5",
   "also_shown_as": "",
   "model": "EON Adora, Hydris (top load; not WTEON ADA/ADAC 80 5.0 FEFN)",
   "meaning": "Motor connection failed",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e5"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E5",
   "also_shown_as": "",
   "model": "EON Rhine (top load)",
   "meaning": "Door switch failure",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e5-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E6",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "Overflow error",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e6"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E7",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "Lid opened while child lock (CL) is on",
   "what_to_do": "Close the lid properly and turn off the child lock.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e7"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "F2",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load; not WTEON ADA/ADAC 80 5.0 FEFN)",
   "meaning": "Heater failure",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-f2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "F3",
   "also_shown_as": "",
   "model": "EON Rhine (top load)",
   "meaning": "PCB (circuit board) failure",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-f3"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "F4",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load; not WTEON ADA/ADAC 80 5.0 FEFN)",
   "meaning": "NTC (temperature sensor) failure",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-f4"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "F5",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "No fuzzy value detection",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-f5"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "F6",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "Low supply voltage",
   "what_to_do": "Switch the machine off at the mains and restart after 5 minutes. Godrej says it should clear by itself when the voltage is back to normal.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-f6"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "F7",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "High supply voltage",
   "what_to_do": "Switch the machine off at the mains and restart after 5 minutes. Godrej says it should clear by itself when the voltage is back to normal.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-f7"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "F8",
   "also_shown_as": "",
   "model": "EON Adora, Hydris, Rhine (top load)",
   "meaning": "Water level circuit or sensor failure",
   "what_to_do": "Call for technical support.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-f8"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "CLOSE THE DOOR",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Display message: door open or not closed properly",
   "what_to_do": "Close the door properly.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-close-the-door"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "d0",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "The door opened while a programme was running",
   "what_to_do": "Close the door properly and restart. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-d0"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "dC",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "The door does not unlock at the end of the cycle",
   "what_to_do": "Restart the machine and check. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-dc"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "tP",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "No water supply or low water pressure",
   "what_to_do": "Check the water supply, water pressure and the inlet filter for blockage.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-tp"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "dP",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Drain path clogged, drain pump not working or filter blocked",
   "what_to_do": "Restart the machine and check. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-dp"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "PS",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Water level sensor not in order",
   "what_to_do": "Restart the machine. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-ps"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "OH",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Maximum temperature reached",
   "what_to_do": "Restart the machine. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-oh"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "nt",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Temperature probe not in order (shown at the end of the cycle)",
   "what_to_do": "Restart the machine. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-nt"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "ht",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Water is not getting hot (shown at the end of the cycle)",
   "what_to_do": "Restart the machine. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-ht"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "LE",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Input supply voltage is low",
   "what_to_do": "The machine continues once the voltage recovers (above 160 V).",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-le"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "HE",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Input supply voltage is high",
   "what_to_do": "The machine continues once the voltage recovers (below 270 V).",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-he"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "OF",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Water overflow",
   "what_to_do": "Restart the machine and check. If the error persists, switch off and call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-of"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "Ub",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Load unbalance during spin (shown at the end of the cycle)",
   "what_to_do": "Restart the machine. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-ub"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E04",
   "also_shown_as": "",
   "model": "EON Cresta (front load)",
   "meaning": "Motor related error",
   "what_to_do": "Restart the machine and check. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e04"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E05",
   "also_shown_as": "",
   "model": "EON Cresta (front load)",
   "meaning": "Motor related error",
   "what_to_do": "Restart the machine and check. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e05"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EXX",
   "also_shown_as": "E20 to E26",
   "model": "EON Regalis (front load)",
   "meaning": "Motor related errors (E20 to E26)",
   "what_to_do": "Restart the machine and check. If the error persists, call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-exx"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "tS",
   "also_shown_as": "",
   "model": "EON Cresta, Regalis (front load)",
   "meaning": "Turbidity sensor calibration needed (shown at the end of the cycle)",
   "what_to_do": "Call a service technician.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-ts"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E30",
   "also_shown_as": "",
   "model": "EON Argon, Celesta (front load)",
   "meaning": "Door not closed properly",
   "what_to_do": "Close the door properly and restart.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e30"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E10",
   "also_shown_as": "",
   "model": "EON Argon, Celesta (front load)",
   "meaning": "Water inlet problem during the wash cycle",
   "what_to_do": "Check the water pressure is high enough, straighten the water pipe and clean the inlet valve filter.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e10"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E21",
   "also_shown_as": "",
   "model": "EON Argon, Celesta (front load)",
   "meaning": "Water draining is taking too long",
   "what_to_do": "Check the drain hose for blockage.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e21"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "E12",
   "also_shown_as": "",
   "model": "EON Argon, Celesta (front load)",
   "meaning": "Water overflow",
   "what_to_do": "Restart the appliance. If water overflows again or the code comes back, switch off and contact Godrej customer service.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-e12"
  },
  {
   "appliance": "washing-machine",
   "brand": "Godrej",
   "code": "EXX",
   "also_shown_as": "",
   "model": "EON Argon, Celesta (front load)",
   "meaning": "Other errors",
   "what_to_do": "Restart the appliance. If the problem persists, contact Godrej customer service.",
   "source": "https://www.godrejenterprises.com/support/appliances/washing-machines/user-manuals-and-catalogues https://static.godrejenterprises.com/EON_Velvet_Classic_22804acf98.pdf https://static.godrejenterprises.com/EON_Velvet_Steam_1369638f90.pdf https://static.godrejenterprises.com/EON_Alpha_Non_Heater_51fa0139e9.pdf https://static.godrejenterprises.com/EON_Magnus_Heater_b764071783.pdf https://static.godrejenterprises.com/EON_Alpha_Heater_fb9163e78a.pdf https://static.godrejenterprises.com/EON_Allure_Classic_0ec34973fc.pdf https://static.godrejenterprises.com/EON_Adora_707ffec3ba.pdf https://static.godrejenterprises.com/EON_Hydris_6f7d859f21.PDF https://static.godrejenterprises.com/EON_Rhine_2e9b0f5b70.pdf https://static.godrejenterprises.com/EON_Cresta_0ce4d89673.pdf https://static.godrejenterprises.com/Eon_Regalis_73808e574f.pdf https://static.godrejenterprises.com/EON_Argon_531b1ba50c.pdf https://static.godrejenterprises.com/EON_Celesta_4598cb3423.pdf https://static.godrejenterprises.com/Edge_Uno_3_d34852a9a5.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/washing-machine/godrej/#code-exx-2"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "EE",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Indoor unit EE fault (Godrej gives no more detail)",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-ee"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E1",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Indoor fan fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e1"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E2",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Indoor fan zero-crossing detection abnormal",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e2"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E3",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Indoor coil fault and sensor fault (18ITC3 manual: indoor coil sensor fault)",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e3"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E4",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Indoor ambient (room) temperature sensor fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e4"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E0",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Outdoor unit EE fault (Godrej gives no more detail)",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e0"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E6",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Indoor and outdoor unit communication fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e6"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E8",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Outdoor communication fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e8"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F1",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Compressor starting abnormal (phase failure, reverse)",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f1"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F2",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Compressor out-of-step fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f2"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F3",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "IPM module fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f3"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F4",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Compressor shell top fault or protection",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f4"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F5",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Discharge temperature sensor fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f5"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F6",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Suction temperature sensor fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f6"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F7",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Outdoor coil temperature sensor fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f7"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F8",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Outdoor ambient temperature sensor fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f8"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "F9",
   "also_shown_as": "",
   "model": "Inverter split",
   "meaning": "Outdoor DC fan fault",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-f9"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "H6/E5",
   "also_shown_as": "",
   "model": "Fixed-speed split",
   "meaning": "Indoor unit fan motor protection: the compressor and fan turn off immediately",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-h6-e5"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "dF",
   "also_shown_as": "",
   "model": "Fixed-speed split",
   "meaning": "Frost protection",
   "what_to_do": "Godrej lists dF as frost protection and gives no steps. If dF keeps coming, switch the AC off and call Godrej authorised service.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-df"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E1",
   "also_shown_as": "",
   "model": "Fixed-speed split",
   "meaning": "Room temperature sensor error (sensor short or open). The display shows E1 and the set temperature by turns.",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e1-2"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E2",
   "also_shown_as": "",
   "model": "Fixed-speed split",
   "meaning": "Evaporator (indoor coil) sensor error (sensor short or open). The display shows E2 and the set temperature by turns.",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e2-2"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "U8",
   "also_shown_as": "",
   "model": "Fixed-speed split (selected models)",
   "meaning": "Zero cross detection",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-u8"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "E3",
   "also_shown_as": "",
   "model": "Fixed-speed split (selected models)",
   "meaning": "Outdoor coil (condenser) sensor error, in heat mode. The display shows E3 and the set temperature by turns.",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-e3-2"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "HF",
   "also_shown_as": "",
   "model": "Fixed-speed split (selected models)",
   "meaning": "Outdoor unit frost protection (in heat mode)",
   "what_to_do": "Godrej lists HF as outdoor unit frost protection in heat mode and gives no steps. If it keeps coming, switch the AC off and call Godrej authorised service.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-hf"
  },
  {
   "appliance": "ac",
   "brand": "Godrej",
   "code": "HP",
   "also_shown_as": "",
   "model": "Fixed-speed split (selected models)",
   "meaning": "Indoor coil overheat protection (in heat mode)",
   "what_to_do": "Switch the AC off and call Godrej authorised service. Godrej's manual gives no repair steps for this code.",
   "source": "https://www.godrejenterprises.com/support/appliances/air-conditioners/user-manuals-and-catalogues https://static.godrejenterprises.com/637523736363601776_GSC_12_ITC_3_WUA_6b20753afc.pdf https://static.godrejenterprises.com/637523767061927024_GSC_18_ITC_3_WTA_e9088786a7.pdf https://static.godrejenterprises.com/637523820596225064_GSC_24_ITC_3_WUA_9d5a3f95c6.pdf https://static.godrejenterprises.com/AC_e_Catalogue_2025_v5_5b0e64a85f.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/ac/godrej/#code-hp"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "UV lamp error",
   "also_shown_as": "blue solid, red Service LED solid, green off",
   "model": "Delight NXT RO+UV+UF+TA",
   "meaning": "UV lamp error",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-uv-lamp-error"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "SV / pump error",
   "also_shown_as": "blue solid, red Service LED flashing every 0.5 s, green off",
   "model": "Delight NXT RO+UV+UF+TA",
   "meaning": "Solenoid valve (SV) or pump error",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-sv-pump-error"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "LPS error",
   "also_shown_as": "blue Power LED flashing every 0.25 s, red and green off",
   "model": "Delight NXT RO+UV+UF+TA",
   "meaning": "No input water (LPS error)",
   "what_to_do": "Check that the water supply to the purifier is on. If water is coming and the light still blinks, call Eureka Forbes service.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-lps-error"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "Temperature sensor fault",
   "also_shown_as": "all LEDs blink red every 0.5 s",
   "model": "Crest UV Hot",
   "meaning": "Temperature sensor fault",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-temperature-sensor-fault"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "UV / LDR fault",
   "also_shown_as": "all LEDs blink: on for 0.5 s, off for 3 s",
   "model": "Crest UV Hot",
   "meaning": "UV lamp or LDR fault",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-uv-ldr-fault"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "SV fault",
   "also_shown_as": "all LEDs blink: on, off, on for 0.5 s, then off for 3 s, repeating",
   "model": "Crest UV Hot",
   "meaning": "Solenoid valve (SV) fault",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-sv-fault"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "EA fault",
   "also_shown_as": "LEDs 2, 5 and 7 solid; LEDs 1 and 3 blink every 0.5 s",
   "model": "Crest UV Hot",
   "meaning": "EA fault: both EA chips not connected, or the main board to junction board harness not connected",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-ea-fault"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "EA fault: combination cartridge",
   "also_shown_as": "LEDs 2, 5 and 7 solid; LED 3 blinks every 0.5 s",
   "model": "Crest UV Hot",
   "meaning": "EA fault on the combination cartridge (blue)",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-ea-fault-combination-cartridge"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "EA fault: active copper cartridge",
   "also_shown_as": "LEDs 2, 5 and 7 solid; LED 1 blinks every 0.5 s",
   "model": "Crest UV Hot",
   "meaning": "EA fault on the active copper cartridge with zinc booster (beige)",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-ea-fault-active-copper-cartridge"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "UV / LDR fault",
   "also_shown_as": "all LEDs blink, buzzer beeps once every 3 s",
   "model": "Zest RO+UV+MTDS+Hot / Crest UV",
   "meaning": "UV lamp or LDR fault",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-uv-ldr-fault-2"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "SV / pump fault",
   "also_shown_as": "all LEDs blink, buzzer beeps twice every 3 s",
   "model": "Zest RO+UV+MTDS+Hot / Crest UV",
   "meaning": "Solenoid valve (SV) or pump fault",
   "what_to_do": "Switch off the purifier and call Eureka Forbes authorised service. Do not open the purifier.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-sv-pump-fault"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "Filter first warning",
   "also_shown_as": "LEDs 2, 3, 6 solid; the filter's LED blinks once every 3 s",
   "model": "Zest RO+UV+MTDS+Hot / Crest UV",
   "meaning": "Filter end of life is nearing (first warning). LED 5 = combination cartridge, LED 1 = active copper with zinc booster.",
   "what_to_do": "Book a filter change with Eureka Forbes service.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-filter-first-warning"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "Filter second warning",
   "also_shown_as": "LEDs 2, 3, 6 solid; the filter's LED blinks twice every 3 s",
   "model": "Zest RO+UV+MTDS+Hot / Crest UV",
   "meaning": "Filter second warning (end of life is near)",
   "what_to_do": "Book a filter change with Eureka Forbes service.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-filter-second-warning"
  },
  {
   "appliance": "water-purifier",
   "brand": "Aquaguard",
   "code": "Filter end of life",
   "also_shown_as": "LEDs 2, 3, 6 solid; the filter's LED blinks three times every 3 s",
   "model": "Zest RO+UV+MTDS+Hot / Crest UV",
   "meaning": "Filter has reached end of life. Eureka Forbes says the unit is seized (stops) at end of life.",
   "what_to_do": "Call Eureka Forbes service to replace the filter cartridge.",
   "source": "https://www.eurekaforbes.com/media/downloadfiles/usermanual/NXT_RO%2BUV%2BTA.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/Aquaguard-CREST-UV%2BHot.pdf https://www.eurekaforbes.com/media/downloadfiles/usermanual/AG_CREST_UM.pdf",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/water-purifier/aquaguard/#code-filter-end-of-life"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-d0",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Button problem: a button was pressed and held for a period of time",
   "what_to_do": "Clean the buttons and make sure there is no water on or around them. Turn the oven off and try again.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-d0"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "S-01",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Safety shutoff, not a fault: the oven kept running at a set temperature for a long time (under 105 °C: 16 hours; 105–240 °C: 8 hours; 245 °C to max: 4 hours)",
   "what_to_do": "Turn the oven off and remove the food, then use it normally again.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-s-01"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "dC / dE",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Divider check: the divider was removed during Dual cook, or put in during Single cook",
   "what_to_do": "Don't remove the divider during Dual cook. Turn the oven off and on again. If the code comes back, switch off the power for 30 seconds or more, then reconnect. If it still shows, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-dc-de"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-d1",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Door lock malfunction",
   "what_to_do": "Turn the oven off and on again. If the code comes back, switch off the power for 30 seconds or more, then reconnect. If it still shows, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-d1"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-20 / C-21 / C-22",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Sensor malfunction",
   "what_to_do": "Turn the oven off and on again. If the code comes back, switch off the power for 30 seconds or more, then reconnect. If it still shows, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-20-c-21-c-22"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-F0",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "No communication between the main PCB and the sub PCB",
   "what_to_do": "Turn the oven off and on again. If the code comes back, switch off the power for 30 seconds or more, then reconnect. If it still shows, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-f0"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-F1",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Occurs during EEPROM (memory) read/write",
   "what_to_do": "Turn the oven off and on again. If the code comes back, switch off the power for 30 seconds or more, then reconnect. If it still shows, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-f1"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-F2",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Communication problem between the touch IC and the main or sub micom (control chip)",
   "what_to_do": "Turn the oven off and on again. If the code comes back, switch off the power for 30 seconds or more, then reconnect. If it still shows, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-f2"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "Pr E",
   "also_shown_as": "",
   "model": "Samsung India support page (no models named)",
   "meaning": "Preheating, not a fault",
   "what_to_do": "Wait. Pr E goes away when the oven reaches the set temperature. Keep the door closed while it preheats.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-pr-e"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-d0 / -SE- / SE",
   "also_shown_as": "",
   "model": "Samsung UK / Philippines / Gulf support pages (no models named)",
   "meaning": "A touch key was pressed for more than 10 seconds",
   "what_to_do": "Unplug the microwave and clean the buttons (dust, water). If it comes back, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-d0-se-se"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-20",
   "also_shown_as": "E-21, E-22",
   "model": "Samsung UK / Philippines / Gulf support pages (no models named)",
   "meaning": "Temperature sensor open or short",
   "what_to_do": "Unplug the microwave and contact Samsung service. Do not open the case.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-20"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-21",
   "also_shown_as": "E-24",
   "model": "Samsung UK / Philippines / Gulf support pages (no models named)",
   "meaning": "Temperature too high: it rose over the limit during cooking (Samsung: \"fire sensed\")",
   "what_to_do": "Unplug the microwave and wait long enough for it to cool before you restart it. If the code comes back, keep it unplugged and contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-21"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-A1",
   "also_shown_as": "E-A1",
   "model": "Samsung UK / Philippines / Gulf support pages (no models named)",
   "meaning": "The microwave could not sense the damper opening or closing for 1 minute",
   "what_to_do": "Unplug the microwave and contact Samsung service. Do not open the case.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-a1"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-F0",
   "also_shown_as": "E-83",
   "model": "Samsung UK / Philippines / Gulf support pages (no models named)",
   "meaning": "No communication between the main and sub micom (control chips)",
   "what_to_do": "Unplug the microwave and contact Samsung service. Do not open the case.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-f0-2"
  },
  {
   "appliance": "microwave",
   "brand": "Samsung",
   "code": "C-F2",
   "also_shown_as": "-tE-, -TE-",
   "model": "Samsung UK / Philippines / Gulf support pages (no models named)",
   "meaning": "Abnormal communication on the touch keys",
   "what_to_do": "Press Stop and try again. If it comes back, contact Samsung service.",
   "source": "https://www.samsung.com/in/support/home-appliances/error-code-on-microwave-display/ https://www.samsung.com/uk/support/home-appliances/displayed-information-codes-on-my-microwave/ https://www.samsung.com/ph/support/home-appliances/samsung-microwave-error-codes/ https://www.samsung.com/ae/support/home-appliances/displayed-information-codes-on-my-microwave/",
   "checked": "2026-10-29",
   "url": "https://faultdecode.com/microwave/samsung/#code-c-f2-2"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "E17",
   "also_shown_as": "F17",
   "model": "Bosch India support page",
   "meaning": "Water supply time exceeded: the machine did not get water in time",
   "what_to_do": "",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-e17"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "E18",
   "also_shown_as": "F18, d02",
   "model": "Bosch India support page",
   "meaning": "No drainage: water may still be in the drum",
   "what_to_do": "",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-e18"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "E:36 / -10",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Water is not being pumped out",
   "what_to_do": "Check the water outlet hose: not too high, kinked, trapped or extended in a way Bosch does not allow. Clean the drain pipe and outlet hose, check the pump cover is fitted correctly, clean the drain pump, and use less detergent next time.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-e-36-10"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "E:36 / -25 / -26",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Drain pump is blocked",
   "what_to_do": "Clean the drain pump (user manual p.32).",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-e-36-25-26"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "E:60 / -2B",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Spin stopped because the laundry is unevenly spread",
   "what_to_do": "Redistribute the laundry in the drum.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-e-60-2b"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "E:30 / -10",
   "also_shown_as": "tap symbol",
   "model": "WAJ24265IN",
   "meaning": "No water, or the water level measuring system is faulty",
   "what_to_do": "Turn on the tap, check the inlet hose is not kinked, clean the filters in the water inflow and check the water pressure. If the level system is faulty the machine drains: wait about 5 minutes, restart, and call service if it stays.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-e-30-10"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "E:30 / -20",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Critical malfunction (also shown for too much detergent or extra water added)",
   "what_to_do": "Turn off the tap. The machine starts draining: wait about 5 minutes, then restart. Use less detergent and never add extra water while it runs. If it stays, call customer service.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-e-30-20"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "Foam symbol",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Heavy foam: too much detergent",
   "what_to_do": "Mix 1 tablespoon of fabric softener with 0.5 litres of water and pour it into compartment II (not for outdoor clothing, sportswear or down-filled items). Use less detergent next time.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-foam-symbol"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "Door symbol flashes",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Door is not completely closed",
   "what_to_do": "Make sure no laundry is caught in the door, then close it.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-door-symbol-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "Drum symbol flashes",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Drum cleaning is required",
   "what_to_do": "Run the Drum Descale programme.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-drum-symbol-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "Voltage symbol flashes",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Power supply fluctuation; programme paused",
   "what_to_do": "No action needed. When the power is stable the programme continues.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-voltage-symbol-flashes"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "Start/Pause flashes, display off",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Energy-saving mode",
   "what_to_do": "Press Start/Pause.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",
   "url": "https://faultdecode.com/washing-machine/bosch/#code-start-pause-flashes-display-off"
  },
  {
   "appliance": "washing-machine",
   "brand": "Bosch",
   "code": "Any other code",
   "also_shown_as": "",
   "model": "WAJ24265IN",
   "meaning": "Malfunction",
   "what_to_do": "Restart. If it comes back, disconnect power for at least 30 seconds. If it still persists, call customer service with the exact code.",
   "source": "https://media3.bsh-group.com/Documents/9001795589_C.pdf https://www.bosch-home.in/service/get-support/error-e17-or-f17-washing-machine https://www.bosch-home.in/service/get-support/e18-in-display",
   "checked": "2026-11-01",